Silage quality and aerobic stability are sometimes insufficient. If management requirements are not met, or to improve silage quality, additives are often used. The objective of this study is to investigate the effects of different factors on silage during aerobic conditions. Whole-crop forage maize was harvested and 24 buckets (65 L) were filled and assigned to one of four treatment groups: (1) control (no treatment); (2) chemical additive (sodium benzoate, potassium sorbate, sodium acetate); (3) a mixed biological inoculant containing Lactobacillus buchneri, L. plantarum, and Pediococcus acidilacti; and (4) a mixed biological inoculant containing L. buchneri, L. plantarum, and L. rhamnosus. An untreated variation was also ensiled. Two different densities were adjusted during ensiling. After opening, the temperature was measured for seven days and O2 and CO2 concentrations were analysed. The findings show that the chemical additive very effectively prevented silage from reheating and deteriorating. Aerobic reheating of silage was also successfully inhibited through biological additives and high density.
Oxygen (O2) concentration inside the substrate is an important measurement for silage-research and-practical management. In the laboratory gas chromatography is commonly employed for O2 measurement. Among sensor-based techniques, accurate and reliable in situ measurement is rare because of high levels of carbon dioxide (CO2) generated by the introduction of O2 in the silage. The presented study focused on assessing three types of commercial O2 sensors, including Clark oxygen electrodes (COE), galvanic oxygen cell (GOC) sensors and the Dräger chip measurement system (DCMS). Laboratory cross calibration of O2versus CO2 (each 0–15 vol.%) was made for the COE and the GOC sensors. All calibration results verified that O2 measurements for both sensors were insensitive to CO2. For the O2in situ measurement in silage, all O2 sensors were first tested in two sealed barrels (diameter 35.7 cm; height: 60 cm) to monitor the O2 depletion with respect to the ensiling process (Test-A). The second test (Test-B) simulated the silage unloading process by recording the O2 penetration dynamics in three additional barrels, two covered by dry ice (0.6 kg or 1.2 kg of each) on the top surface and one without. Based on a general comparison of the experimental data, we conclude that each of these in situ sensor monitoring techniques for O2 concentration in silage exhibit individual advantages and limitations.
For silage production, high bulk density (BD) is critical to minimize aerobic deterioration facilitated by oxygen intrusion. To precisely assess packing quality for bunker silos, there is a desire to visualize the BD distribution within the silage. In this study, a penetrometer-based mapping system was developed. The data processing included filtering of the penetration friction component (PFC) out of the penetration resistance (PR), transfer of the corrected penetration resistance (PRc) to BD, incorporation of Kriged interpolation for data expansion and map generation. The experiment was conducted in a maize bunker silo (width: 8 m, middle height: 3 m). The BD distributions near the bunker silo face were represented using two map groups, one related to horizontal- and the other to vertical-density distribution patterns. We also presented a comparison between the map-based BD results and core sampling data. Agreement between the two measurement approaches (RMSE = 19.175 kg·m−3) demonstrates that the developed penetrometer mapping system may be beneficial for rapid assessment of aerobic deterioration potential in bunker silos.