We have demonstrated a precision atom-interferometry gravimeter based on matter-wave Bragg diffraction. By decreasing the atom temperature and increasing the atom number with Raman sideband cooling, it is shown that our Bragg atom gravimeter can achieve a short-term sensitivity of ), improved by nearly a factor of 2 compared to that of a state-of-the-art atom gravimeter. The resolution of our atom gravimeter has reached after an integration time of 2000 s, comparable to a cryogenic superconducting gravimeter. Based on extremely sensitive and stable gravity measurements, a test of local Lorentz invariance in the gravity sector was performed, where the accuracy of the upper bound on the space-space component was improved by a factor of 4.
As a novel instrument for measuring absolute gravity, the atom gravimeter has shown high sensitivity and stability in the past three decades. In this work, we report a car-based portable atom gravimeter whose sensitivity is at the level of (1 Gal = 0.01 m/s2) both for lab and outdoor measurements. Its resolution can reach 30 μGal within an integration time of 10 000 s when located in a quiet place. During four months of gravity observation, there is no drift for the measurement result, showing that this car-based gravimeter has a competitive advantage at long term stability. By using this car-based atom gravimeter in the open air, the field gravity measurements with sub-mGal performance have been demonstrated in the mountain gravity survey. According to the gravity measurement results from our car-based atom gravimeter, the density distribution of this mountain is inverted, which is consistent with the result from the geological exploration.
Atom interferometry provides an important method of high-precision absolute gravity measurement. As absolute gravimeters, various systematic errors of atom gravimeters have been identified and evaluated. Here a comprehensive evaluation of systematic errors for a transportable atom gravimeter Huazhong University of Science and Technology-Quantum Gravimeter (HUST-QG) is presented. HUST-QG exhibited a short-term sensitivity of 24 μGal Hz−1/2 and a combined uncertainty of 3 μGal. The operation and evaluation of HUST-QG for transportable gravity measurements during the 10th International Comparison of Absolute Gravimeters are discussed. And the degree of equivalence for HUST-QG in this comparison is 1.3 μGal, which supports our evaluation.
Matter-wave sensors with cold atoms have progressed tremendously over recent decades. We report a sensitive tilt sensor based on quantum technology employing cold atoms. This quantum tiltmeter is constructed with the configuration of a Ramsey-Bordé atom interferometer, achieving an improvement of nearly three orders of magnitude for tilt measurements with a short-term sensitivity of , with resolution down to at an integration time of 1000 s. The deformation of the Earth's surface has been monitored in a continuous run of 31 h, showing that a quantum tiltmeter can be applied to record tilt tides and can be an valuable sensor in geophysics and various scientific facilities.
We present a matter wave gyroscope with a Sagnac area of 5.92 cm2, achieving a short-term sensitivity of 167 nrad/s/Hz1/2. The atom interferometry gyroscope is driven by a π/2 − π − π − π/2 Raman pulse sequence based on an atom fountain with a parabolic trajectory. The phase-locked laser beams for Raman transitions partly propagate outside of the vacuum chamber and expose to the air when passing through the two arms of the vacuum chamber. This configuration leads to the tilt of the laser’s wave-front and suffers the fluctuation of air density. The impacts on both the fringe contrast and long-term stability are experimentally investigated in detail, and effective schemes are developed to improve the performance of our atom gyroscope. The method presented here could be useful for developing large atom interferometry facilities with separated vacuum chambers.