Ivan Ignatkin

Dr. Ivan Ignatkin

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2023 in Agriculture
Verified
Journal Article
Open access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
SKSergey Kazantsev
Sergey Kazantsev
NSNikolay Shevkun
Nikolay Shevkun
DSDmitry Skorokhodov
Dmitry Skorokhodov
NSNikita Serov
Nikita Serov
Vladimir PanchenkoVladimir Panchenko
Vladimir Panchenko
This article presents the results of developing and testing the air-cooling system of a combined climate control unit used in pig farming. The authors have found a water-evaporative system to be the most efficient for cooling the air supply. Cooling systems of this type consume 0.003 kW/kW of electric power to produce 1 kW of cold. Based on the developed mathematical model for water-evaporative cooling in the combined climate control unit, the authors have determined that an air supply with a temperature of 31.2 °C and a relative humidity of 30.4% can be cooled by 8.3 °C when saturated with moisture to a relative humidity of 90.0% (by 11.7 °C at 100%). Experimental studies of the cooling system confirmed the theoretically obtained data.

1 March 2025 in Technical Physics
Verified
Journal Article
Closed access
PDF file
NSN. V. Serov
N. V. Serov
OMO. M. Melnikov
O. M. Melnikov
SKS. P. Kazantsev
S. P. Kazantsev
IIIvan Ignatkin
Ivan Ignatkin
ASA. V. Serov
A. V. Serov
Difficulties in the delivery of machinery, equipment, and spare parts, as well as the limitedness of financial resources for agricultural enterprises, necessitate upgrading of machine maintenance processes and technologies. The damage of radiators in the liquid cooling system of internal combustion engines is one reason for equipment failure. To develop a technique for mechanical damage repair, analysis of the radiator designs has been performed and prevailing defects have been revealed. It has been found that aluminum or copper‒brass radiators are most commonly used in the cooling system of internal combustion engines. Maun in-service defects are mechanical damage of internal combustion engine radiators in the form of leaky tubes and cooling tape (or plate) separation. These defects are most frequently removed by soldering with tin‒lead solders, blanking off leaky tubes, pouring polymer sealants into the cooling liquid, and taping. For the case of radiator mechanical damage, it has been suggested that cold gasdynamic spraying of a metallic layer is applied using a Dimet-405 setup. The surface was subjected to preliminary abrasive treatment by a K00-04-16 corundum powder. Optimal spraying conditions have been suggested: for A-20-11 powder at 100°C (regime 1) or 200°C (regime 2) and for C-01-11 powder at 200°C (regime 2) or 300°C (regime 3). The powder feed rate was 0.3 g/s. The strength of obtained joints was no lower than that of joints obtained using tin‒lead solder. A technique for leakage stopping and cooling tape‒tube contact restoration developed by the authors makes it possible to rapidly and reliably repair damaged radiators. The repair of radiators used in the engine cooling system will allow one to cut the machine down time.

16 December 2023
Verified
Book Chapter
Closed access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
NSNikolay Shevkun
Nikolay Shevkun
AKA. S. Kononenko
A. S. Kononenko
VRV. Ryabchikova
V. Ryabchikova
Vladimir PanchenkoVladimir Panchenko
Vladimir Panchenko

20 March 2026 in Thermo
Verified
Journal Article
Open access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
NSNikolay Shevkun
Nikolay Shevkun
DSDmitry Skorokhodov
Dmitry Skorokhodov
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air. The implementation of evaporative cooling depends largely on the interaction of the media involved in this process. This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger. A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained. The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode. Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out. The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia. The panel evaporative coolers provided a temperature reduction of 11.3 °C without any splashing effect. Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.5 °C, accompanied by splashing. When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.1 °C, which is 11% lower, compared with the paper pads. The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate. Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value. Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.

1 January 2024 in Agricultural engineering
Verified
Journal Article
Open access
PDF file
TATimirâzevskaâ Selʹskohozâjstvennaâ Akademiâ
Timirâzevskaâ Selʹskohozâjstvennaâ Akademiâ
NSNikita V. Serov
Nikita V. Serov
ОМО. М. Мельников
О. М. Мельников
СКС. П. Казанцев
С. П. Казанцев
IIIvan Ignatkin
Ivan Ignatkin
АПА. Е. Павлов
А. Е. Павлов
Difficulties in the supply of machinery, equipment and spare parts and the limited financial resources of agricultural enterprises make it necessary to improve the technology and process of machine repair. Damaged radiators in the liquid cooling system of internal combustion engines are one of the most common causes of failure of agricultural machinery. In the course of the research it was found that the most common types of radiators used in cooling systems of agricultural engines are aluminum or brass-copper radiators. The main defects that occur during operation are such mechanical damages of radiators as leaks in tubes and torn off cooling plates or tapes. The most common methods of eliminating these defects are: soldering with tin-lead solders, plugging leaking tubes, pouring polymer sealants into the coolant, and taping. In the case of mechanical damage of radiators, the authors suggest the use of cold gas-dynamic spraying of the metal layer with Dimet‑405. The preliminary abrasive surface preparation is carried out with a corundum powder of K00‑04‑16 grade. The optimum spraying modes are proposed: for the A‑20‑11 powder - at the temperature of 100 or 200°C (the first or the second modes, respectively), for the C‑01‑11 powder - at 200 or 300°C (the second or the third modes, respectively). The powder feed rate is 0.3 g/s. The strength of the obtained connections is not inferior to the strength of the soldered connection made with lead-tin solders. The technology developed by the authors for sealing leaks and restoring the contact of the cooling tapes with tubes can contribute to the fast and high-quality repair of damaged radiators. Repairing radiators of the engine cooling system reduces the forced downtime of machines.