Nikolay Shevkun

Dr. Nikolay Shevkun

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2023 in Agriculture
Verified
Journal Article
Open access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
SKSergey Kazantsev
Sergey Kazantsev
NSNikolay Shevkun
Nikolay Shevkun
DSDmitry Skorokhodov
Dmitry Skorokhodov
NSNikita Serov
Nikita Serov
Vladimir PanchenkoVladimir Panchenko
Vladimir Panchenko
This article presents the results of developing and testing the air-cooling system of a combined climate control unit used in pig farming. The authors have found a water-evaporative system to be the most efficient for cooling the air supply. Cooling systems of this type consume 0.003 kW/kW of electric power to produce 1 kW of cold. Based on the developed mathematical model for water-evaporative cooling in the combined climate control unit, the authors have determined that an air supply with a temperature of 31.2 °C and a relative humidity of 30.4% can be cooled by 8.3 °C when saturated with moisture to a relative humidity of 90.0% (by 11.7 °C at 100%). Experimental studies of the cooling system confirmed the theoretically obtained data.

20 March 2026 in Thermo
Verified
Journal Article
Open access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
NSNikolay Shevkun
Nikolay Shevkun
DSDmitry Skorokhodov
Dmitry Skorokhodov
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or evaporative cooling, which is the simplest way to cool the air. The implementation of evaporative cooling depends largely on the interaction of the media involved in this process. This paper considers the process of interaction of cooling water with the surface of a cellular polycarbonate heat exchanger. A mathematical model describing the process of wetting the sprayed surface of the heat exchanger is obtained. The authors determined the theoretical water flow rate required to provide air cooling for a given operation mode. Experimental trials of a recuperative heat recovery unit with a heat exchanger made of cellular polycarbonate equipped with a water evaporative cooling system were carried out. The authors conducted a comparative assessment to evaluate the effectiveness of evaporative cooling in a heat recovery unit equipped with a polycarbonate heat exchanger versus panel evaporative systems using wetted paper pads at pig farms in the Vladimir and Tambov regions of Russia. The panel evaporative coolers provided a temperature reduction of 11.3 °C without any splashing effect. Under the same operating conditions, the heat recovery unit achieved an inlet air temperature reduction of 10.5 °C, accompanied by splashing. When the water flow rate supplied for evaporation was reduced until the splashing ceased, the cooling temperature drop decreased to 10.1 °C, which is 11% lower, compared with the paper pads. The study revealed characteristic operating modes for the unit that ensure effective air cooling, depending on the cooling water flow rate. Since the prevailing temperature during the system’s main operating time is significantly lower than the design temperature (the absolute temperature maximum), to achieve effective cooling of the supply air without splashing or excessive water waste, the cooling circuit water should circulate at a flow rate within 40 to 63% of the maximum design value. Alternatively, an automated control system should be employed to regulate the water supply based on outdoor air temperature and humidity.

16 December 2023
Verified
Book Chapter
Closed access
PDF file
IIIvan Ignatkin
Ivan Ignatkin
NSNikolay Shevkun
Nikolay Shevkun
AKA. S. Kononenko
A. S. Kononenko
VRV. Ryabchikova
V. Ryabchikova
Vladimir PanchenkoVladimir Panchenko
Vladimir Panchenko

1 January 2023 in Agricultural engineering
Verified
Journal Article
Open access
PDF file
NSNikolay Shevkun
Nikolay Shevkun
One of the ways to reduce the cost of heating production facilities in animal husbandry is the use of regenerative heat recovery plants. However, the existing designs of heat exchangers have a number of design flaws affecting their functionality, in particular, the uneven distribution of the air flow over the surface of a heat exchanger. This, in turn, does not provide for a more complete utilization of exhaust air heat. Using the example of a recuperative heat recovery unit UT‑3000, the authors consider the possibility of retrofitting it with an aerodynamic grid to evenly distribute the exhaust air flow over the heat exchanger surface and reduce energy costs for its operation. To do this, they analyzed the applicability of the aerodynamic grid. The size of a blade chord was taken into account as an optimisation parameter. The pressure losses calculated on the “fan - pallet - heat exchanger” section showed that the use of an aerodynamic grid with a “normal” number of blades would create a minimum airflow pressure loss of 0.73 Pa minimum airflow pressure loss of 0.73 Pa, which is 58% less than in the version without an aerodynamic grid. Further experimental study of the uniform airflow distribution over the heat exchanger surface aimed at improving the energy efficiency of the heat recovery unit requires a new design of a heat exchanger with an aerodynamic grid, taking into account the recommended range of “normal” number of blades from 16 to 21, the blade circumference arc of 95° and the blade pitch angle ranging between 68 and 82°.