Aminreza Khandan

Dr. Aminreza Khandan

Mechanical engineering, University of Alberta, Edmonton, Alberta, Canada
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Biomechanics
Verified
Journal Article
Closed access
MNMilad Nazarahari
Milad Nazarahari
AKAminreza Khandan
Aminreza Khandan
AKAtif Khan
Atif Khan
HRHossein Rouhani
Hossein Rouhani

4 February 2022 in Sports Biomechanics
Verified
Journal Article
Closed access
RFRamin Fathian
Ramin Fathian
AKAminreza Khandan
Aminreza Khandan
LCLoren Z. F. Chiu
Loren Z. F. Chiu
HRHossein Rouhani
Hossein Rouhani
The countermovement vertical jump height, flight time, and jump duration are used to assess athletic performance. Force-plate and motion-capture cameras are used to estimate these parameters, yet, their application is limited to dedicated lab environments. Despite the potential of inertial measurement units (IMU) for estimating the jump height, their accuracy has not been validated. This study investigates the accuracy of our proposed method to estimate the jump height using a sacrum-mounted IMU, during countermovement jumping. Eleven individuals performed four jumps each. To obtain the jump height, we transformed the IMU readouts into anatomical planes, and double-integrated the vertical acceleration after correction for zero velocity and vertical displacement. The accuracy of jump height obtained by IMU was compared to force-plate and motion-capture cameras during jumps without arm swing (mean error (standard deviation) of 0.3(2.2) cm and 1.0(3.0) cm, and correlation coefficient of 0.83 and 0.82, respectively) and during jumps with arm swing (−1.1(2.1) cm and 0.5(1.9) cm, and 0.92 and 0.89). The correlation coefficients were high, and the errors were comparable to the difference between the jump height obtained by force-plate and cameras. Therefore, a sacrum-mounted IMU can be recommended for in-field assessment of countermovement jump with and without arm swing.

30 May 2024 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
RFRamin Fathian
Ramin Fathian
AKAminreza Khandan
Aminreza Khandan
NRNasim Rahmanifar
Nasim Rahmanifar
CHChester Ho
Chester Ho
HRHossein Rouhani
Hossein Rouhani
Upper extremity pain and injury are among the most common musculoskeletal complications manual wheelchair users face. Assessing the temporal parameters of manual wheelchair propulsion, such as propulsion duration, cadence, push duration, and recovery duration, is essential for providing a deep insight into the mobility, level of activity, energy expenditure, and cumulative exposure to repetitive tasks and thus providing personalized feedback. The purpose of this paper is to investigate the use of inertial measurement units (IMUs) to estimate these temporal parameters by identifying the start and end time of hand contact with the push-rim during each propulsion cycle. We presented a model based on data collected from 23 participants (14 males and 9 females, including 9 experienced manual wheelchair users) to guarantee the reliability and generalizability of our method. The obtained outcomes from our IMU-based model were then compared against an instrumented wheelchair (SMARTWheel) as a reference criterion. The results illustrated that our model was able to accurately detect hand contact and hand release and predict temporal parameters, including the push duration and recovery duration in manual wheelchair users, with the mean error ± standard deviation of 10 ± 60 milliseconds and -20 ± 80 milliseconds, respectively. The findings of this study demonstrate the potential of hand-mounted IMUs as a reliable and objective tool for analyzing temporal parameters in manual wheelchair propulsion. IMUs offer significant strides towards inclusivity and accessibility due to their portability and user-friendliness and can democratize health monitoring of manual wheelchair users by making it accessible to a broader range of users compared to traditional technologies.

28 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AKAminreza Khandan
Aminreza Khandan
RFRamin Fathian
Ramin Fathian
JCJason P. Carey
Jason P. Carey
HRHossein Rouhani
Hossein Rouhani
Hockey skating objective assessment can help coaches detect players’ performance drop early and avoid fatigue-induced injuries. This study aimed to calculate and experimentally validate the 3D angles of lower limb joints of hockey skaters obtained by inertial measurement units and explore the effectiveness of the on-ice distinctive features measured using these wearable sensors in differentiating low- and high-calibre skaters. Twelve able-bodied individuals, six high-calibre and six low-calibre skaters, were recruited to skate forward on a synthetic ice surface. Five IMUs were placed on their dominant leg and pelvis. The 3D lower-limb joint angles were obtained by IMUs and experimentally validated against those obtained by a motion capture system with a maximum root mean square error of 5 deg. Additionally, among twelve joint angle-based distinctive features identified in other on-ice studies, only three were significantly different (p-value < 0.05) between high- and low-calibre skaters in this synthetic ice experiment. This study thus indicated that skating on synthetic ice alters the skating patterns such that the on-ice distinctive features can no longer differentiate between low- and high-calibre skating joint angles. This wearable technology has the potential to help skating coaches keep track of the players’ progress by assessing the skaters’ performance, wheresoever.

11 January 2024 in Biomechanics
Verified
Journal Article
Open access
PDF file
PMPouyan Mehryar
Pouyan Mehryar
MSMohammad S. Shourijeh
Mohammad S. Shourijeh
TRTahmineh Rezaeian
Tahmineh Rezaeian
AKAminreza Khandan
Aminreza Khandan
NMNeil Messenger
Neil Messenger
ADAbbas Dehghani-Sanij
Abbas Dehghani-Sanij
Facing above-knee amputation poses a significant hurdle due to its profound impact on walking ability. To overcome this challenge, a complex adaptation strategy is necessary at the neuromuscular level to facilitate safe movement with a prosthesis. Prior research conducted on lower-limb amputees has shown a comparable amount of intricacy exhibited by the neurological system, regardless of the level of amputation and state of walking. This research investigated the differences in muscle synergies among individuals with unilateral transfemoral amputations during walking at three different speeds of transient-state gait. Surface electromyography was recorded from eleven male transfemoral amputees’ intact limbs (TFA), and the concatenated non-negative matrix factorization technique was used to identify muscle synergy components, synergy vectors (S), and activation coefficient profiles (C). Results showed varying levels of correlation across paired-speed comparisons in TFA, categorized as poor (S1), moderate (S3 and S4), and strong (S2). Statistically significant differences were observed in all activation coefficients except C3, particularly during the stance phase. This study can assist therapists in understanding muscle coordination in TFA during unsteady gait, contributing to rehabilitation programs for balance and mobility improvement, and designing myoelectric prosthetic systems to enhance their responsiveness to trips or falls.

12 May 2026 in Diabetology
Verified
Journal Article
Open access
PDF file
Aria RabetAria Rabet
Aria Rabet
AKAminreza Khandan
Aminreza Khandan
ARArian Rabet
Arian Rabet
Mohammad Dehghan RouziMohammad Dehghan Rouzi
Mohammad Dehghan Rouzi
FRFabiola Guadalupe Rodriguez
Fabiola Guadalupe Rodriguez
Bijan NajafiBijan Najafi
Bijan Najafi
Background: Smart offloading technologies enable the real-time, objective monitoring of adherence in patients with diabetic foot ulcers (DFUs). Although remote tracking may reinforce adherence and improve wound healing, effectiveness depends on sustained device use, particularly as devices are often removed during rest periods. Real-time, behavior-contingent feedback informed by sensor data, including AI-supported messaging capable of detecting nonadherence, may enhance reinforcement. However, the feasibility and behavioral impact of such strategies remain unclear. Methods: We conducted a prospective feasibility case series nested within a larger DFU cohort of 210 participants, enrolling eight adults with active DFUs. Participants used a sensor-integrated offloading device paired with a smartwatch (SmartBoot) and a mobile application (CORA) that delivered notifications to their smartphones. Notifications were either schedule-based or context-aware, using real-time SmartBoot data to generate personalized messages. The primary outcome was a sensor-detected transition from nonadherent to adherent offloading within 60 min. Results: A total of 130 notifications were delivered, with 125 included in the behavioral response analysis. Context-aware notifications demonstrated higher transition rates than schedule-based notifications. Adaptive Reinforcement yielded the highest response rate (77.4%, 24/31), followed by Clinical Course Correction (71.4%, 20/28), whereas Safety and Technical Assurance (40.7%, 11/27) and Motivational Coaching (30.8%, 12/39) showed lower response rates. Conclusions: Real-time, context-aware feedback is feasible and associated with improved short-term adherence, supporting evaluation in larger trials.