Neil James Stewart

Dr. Neil James Stewart

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2021 in British Journal of Radiology
Verified
Journal Article
Open access
NSNeil James Stewart
Neil James Stewart
LSLaurie J Smith
Laurie J Smith
Ho-Fung ChanHo-Fung Chan
Ho-Fung Chan
JEJames A Eaden
James A Eaden
SRSmitha Rajaram
Smitha Rajaram
JWJim M. Wild
Jim M. Wild
The use of pulmonary MRI in a clinical setting has historically been limited. Whilst CT remains the gold-standard for structural lung imaging in many clinical indications, technical developments in ultrashort and zero echo time MRI techniques are beginning to help realise non-ionising structural imaging in certain lung disorders. In this invited review, we discuss a complementary technique – hyperpolarised (HP) gas MRI with inhaled 3He and 129Xe – a method for functional and microstructural imaging of the lung that has great potential as a clinical tool for early detection and improved understanding of pathophysiology in many lung diseases. HP gas MRI now has the potential to make an impact on clinical management by enabling safe, sensitive monitoring of disease progression and response to therapy. With reference to the significant evidence base gathered over the last two decades, we review HP gas MRI studies in patients with a range of pulmonary disorders, including COPD/emphysema, asthma, cystic fibrosis, and interstitial lung disease. We provide several examples of our experience in Sheffield of using these techniques in a diagnostic clinical setting in challenging adult and paediatric lung diseases.

27 April 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
NSNeil James Stewart
Neil James Stewart
GNGraham Norquay
Graham Norquay
PGPaul D. Griffiths
Paul D. Griffiths
JWJim M. Wild
Jim M. Wild

15 April 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MRMadhwesha Rao
Madhwesha Rao
NSNeil James Stewart
Neil James Stewart
GNGraham Norquay
Graham Norquay
PGPaul D. Griffiths
Paul D. Griffiths
JWJim M. Wild
Jim M. Wild
Purpose: Upon inhalation, xenon diffuses into the bloodstream and is transported to the brain, where it dissolves in various compartments of the brain. Although up to five chemically distinct peaks have been previously observed in129Xe rat head spectra, to date only three peaks have been reported in the human head. This study demonstrates high resolution spectroscopy and chemical shift imaging (CSI) of129Xe dissolved in the human head at 1.5 Tesla.Methods: A129Xe radiofrequency coil was built in‐house and129Xe gas was polarized using spin‐exchange optical pumping. Following the inhalation of129Xe gas, NMR spectroscopy was performed with spectral resolution of 0.033 ppm. Two‐dimensional CSI in all three anatomical planes was performed with spectral resolution of 2.1 ppm and voxel size 20 mm × 20 mm.Results: Spectra of hyperpolarized129Xe dissolved in the human head showed five distinct peaks at 188 ppm, 192 ppm, 196 ppm, 200 ppm, and 217 ppm. Assignment of these peaks was consistent with earlier studies.Conclusion: High resolution spectroscopy and CSI of hyperpolarized129Xe dissolved in the human head has been demonstrated. For the first time, five distinct NMR peaks have been observed in129Xe spectra from the human head in vivo. Magn Reson Med 75:2227–2234, 2016. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

16 October 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
Ho-Fung ChanHo-Fung Chan
Ho-Fung Chan
NSNeil James Stewart
Neil James Stewart
GNGraham Norquay
Graham Norquay
GCGuilhem J. Collier
Guilhem J. Collier
JWJim M. Wild
Jim M. Wild
Purpose: To obtain whole lung morphometry measurements from 129Xe in a single breath‐hold with 3D multiple b‐value 129Xe diffusion‐weighted MRI (DW‐MRI) with an empirically optimized diffusion time and compressed sensing for scan acceleration.Methods: Prospective three‐fold undersampled 3D multiple b‐value hyperpolarized 129Xe DW‐MRI datasets were acquired, and the diffusion time (Δ) was iterated so as to provide diffusive length scale (LmD) estimates from the stretched exponential model (SEM) that are comparable to those from 3He. The empirically optimized 129Xe diffusion time was then implemented with a four‐fold undersampling scheme and was prospectively benchmarked against 3He measurements in a cohort of five healthy volunteers, six ex‐smokers, and two chronic obstructive pulmonary disease patients using both SEM‐derived LmD and cylinder model (CM)‐derived mean chord length (Lm).Results: Good agreement between the mean 129Xe and 3He LmD (mean difference, 2.2%) and Lm (mean difference, 1.1%) values was obtained in all subjects at an empirically optimized 129Xe Δ = 8.5 ms.Conclusion: Compressed sensing has facilitated single‐breath 3D multiple b‐value 129Xe DW‐MRI acquisitions, and results at 129Xe Δ = 8.5 ms indicate that 129Xe provides a viable alternative to 3He for whole lung morphometry mapping with either the SEM or CM. Magn Reson Med 79:2986–2995, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

1 July 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NSNeil James Stewart
Neil James Stewart
FHFelix C. Horn
Felix C. Horn
GNGraham Norquay
Graham Norquay
GCGuilhem J. Collier
Guilhem J. Collier
DYDenise P. Yates
Denise P. Yates
JWJim M. Wild
Jim M. Wild
Purpose To evaluate the reproducibility of indices of lung microstructure and function derived from 129Xe chemical shift saturation recovery (CSSR) spectroscopy in healthy volunteers and patients with chronic obstructive pulmonary disease (COPD), and to study the sensitivity of CSSR-derived parameters to pulse sequence design and lung inflation level. Methods Preliminary data were collected from five volunteers on three occasions, using two implementations of the CSSR sequence. Separately, three volunteers each underwent CSSR at three different lung inflation levels. After analysis of these preliminary data, five COPD patients were scanned on three separate days, and nine age-matched volunteers were scanned three times on one day, to assess reproducibility. Results CSSR-derived alveolar septal thickness (ST) and surface-area-to-volume (S/V) ratio values decreased with lung inflation level (P < 0.001; P = 0.057, respectively). Intra-subject standard deviations of ST were lower than the previously measured differences between volunteers and subjects with interstitial lung disease. The mean coefficient of variation (CV) values of ST were 3.9 ± 1.9% and 6.0 ± 4.5% in volunteers and COPD patients, respectively, similar to CV values for whole-lung carbon monoxide diffusing capacity. The mean CV of S/V in volunteers and patients was 14.1 ± 8.0% and 18.0 ± 19.3%, respectively. Conclusion 129Xe CSSR presents a reproducible method for estimation of alveolar septal thickness. Magn Reson Med 77:2107–2113, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

26 September 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
EHEsben Søvsø Szocska Hansen
Esben Søvsø Szocska Hansen
NSNeil James Stewart
Neil James Stewart
JWJim M. Wild
Jim M. Wild
HSHans Stødkilde‐Jørgensen
Hans Stødkilde‐Jørgensen
CLChristoffer Laustsen
Christoffer Laustsen