Objective: Sleep apnea syndrome (SAS) is a common sleep disorder, which has been shown to be an important contributor to major neurocognitive and cardiovascular sequelae. Considering current diagnostic strategies are limited with bulky medical devices and high examination expenses, a large number of cases go undiagnosed. To enable large-scale screening for SAS, wearable photoplethysmography (PPG) technologies have been used as an early detection tool. However, existing algorithms are energy-intensive and require large amounts of memory resources, which are believed to be the major drawbacks for further promotion of wearable devices for SAS detection. Methods: In this paper, an energy-efficient method of SAS detection based on hyperdimensional computing (HDC) is proposed. Inspired by the phenomenon of chunking in cognitive psychology as a memory mechanism for improving working memory efficiency, we proposed a one-dimensional block local binary pattern (1D-BlockLBP) encoding scheme combined with HDC to preserve dominant dynamical and temporal characteristics of pulse rate signals from wearable PPG devices. Results: Our method achieved 70.17 $\%$ accuracy in sleep apnea segment detection, which is comparable with traditional machine learning methods. Additionally, our method achieves up to 67× lower memory footprint, 68× latency reduction, and 93× energy saving on the ARM Cortex-M4 processor. Conclusion: The simplicity of hypervector operations in HDC and the novel 1D-BlockLBP encoding effectively preserve pulse rate signal characteristics with high computational efficiency. Significance: This work provides a scalable solution for long-term home-based monitoring of sleep apnea, enhancing the feasibility of consistent patient care.
Congestive heart failure (CHF) is a chronic cardiovascular condition associated with dysfunction of the autonomic nervous system (ANS). Heart rate variability (HRV) has been widely used to assess ANS. This paper proposes a new HRV analysis method, which uses information-based similarity (IBS) transformation and fuzzy approximate entropy (fApEn) algorithm to obtain the fApEn_IBS index, which is used to observe the complexity of autonomic fluctuations in CHF within 24 h. We used 98 ECG records (54 health records and 44 CHF records) from the PhysioNet database. The fApEn_IBS index was statistically significant between the control and CHF groups (p < 0.001). Compared with the classical indices low-to-high frequency power ratio (LF/HF) and IBS, the fApEn_IBS index further utilizes the changes in the rhythm of heart rate (HR) fluctuations between RR intervals to fully extract relevant information between adjacent time intervals and significantly improves the performance of CHF screening. The CHF classification accuracy of fApEn_IBS was 84.69%, higher than LF/HF (77.55%) and IBS (83.67%). Moreover, the combination of IBS, fApEn_IBS, and LF/HF reached the highest CHF screening accuracy (98.98%) with the random forest (RF) classifier, indicating that the IBS and LF/HF had good complementarity. Therefore, fApEn_IBS effusively reflects the complexity of autonomic nerves in CHF and is a valuable CHF assessment tool.
Obstructive sleep apnea (OSA) is a common respiratory disorder associated with autonomic nervous system (ANS) dysfunction, resulting in abnormal heart rate variability (HRV). Capable of acquiring heart rate (HR) information with more convenience, wearable photoplethysmography (PPG) bracelets are proven to be a potential surrogate for electrocardiogram (ECG)-based devices. Meanwhile, bracelet-type PPG has been heavily marketed and widely accepted. This study aims to investigate the algorithm that can identify OSA with wearable devices. The information-based similarity of ordinal pattern sequences (OP_IBS), which is a modified version of the information-based similarity (IBS), has been proposed as a novel index to detect OSA based on wearable PPG signals. A total of 92 PPG recordings (29 normal subjects, 39 mild–moderate OSA subjects and 24 severe OSA subjects) were included in this study. OP_IBS along with classical indices were calculated. For severe OSA detection, the accuracy of OP_IBS was 85.9%, much higher than that of the low-frequency power to high-frequency power ratio (70.7%). The combination of OP_IBS, IBS, CV and LF/HF can achieve 91.3% accuracy, 91.0% sensitivity and 91.5% specificity. The performance of OP_IBS is significantly improved compared with our previous study based on the same database with the IBS method. In the Physionet database, OP_IBS also performed exceptionally well with an accuracy of 91.7%. This research shows that the OP_IBS method can access the HR dynamics of OSA subjects and help diagnose OSA in clinical environments.