Bin Liu

Dr. Bin Liu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LRLei Ren
Lei Ren
SXShujia Xu
Shujia Xu
JGJie Gao
Jie Gao
ZLZi Lin
Zi Lin
ZCZhipeng Chen
Zhipeng Chen
Lelun JiangLelun Jiang
Lelun Jiang
Laser-direct writing (LDW) and magneto-rheological drawing lithography (MRDL) have been proposed for the fabrication of a flexible microneedle array electrode (MAE) for wearable bio-signal monitoring. Conductive patterns were directly written onto the flexible polyethylene terephthalate (PET) substrate by LDW. The microneedle array was rapidly drawn and formed from the droplets of curable magnetorheological fluid with the assistance of an external magnetic field by MRDL. A flexible MAE can maintain a stable contact interface with curved human skin due to the flexibility of the PET substrate. Compared with Ag/AgCl electrodes and flexible dry electrodes (FDE), the electrode–skin interface impedance of flexible MAE was the minimum even after a 50-cycle bending test. Flexible MAE can record electromyography (EMG), electroencephalography (EEG) and static electrocardiography (ECG) signals with good fidelity. The main features of the dynamic ECG signal recorded by flexible MAE are the most distinguishable with the least moving artifacts. Flexible MAE is an attractive candidate electrode for wearable bio-signal monitoring.

27 April 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LRLei Ren
Lei Ren
ZCZhipeng Chen
Zhipeng Chen
HWHongjian Wang
Hongjian Wang
ZDZu-Lin Dou
Zu-Lin Dou
BLBin Liu
Bin Liu
Lelun JiangLelun Jiang
Lelun Jiang
Continuous electroencephalogram (EEG) recording is vital for brain science research, monitoring pathological and physiological conditions, and the diagnosis of brain disease. Conventional wet electrodes require skin preparation and a gel electrolyte to reduce electrode-skin interface impedance (EII), which limits its further application in long-term EEG signal recording. Microneedle-array electrodes (MAEs) have been employed in EEG recording, as they can be used directly without skin preparation or the gel electrolyte. However, most microneedles used in MAE are rigid and have a high aspect ratio; thus, they can break easily. Hence, we developed a novel bendable MAE for EEG recording. It is made of a flexible polydimethylsiloxane (PDMS) pillar array with rigid microneedle tips. The PDMS pillar array could help the MAE pass through hair and enable the microneedle tips to penetrate a stratum corneum layer into a scalp, thus reducing the EII. Moreover, the PDMS pillar array is bendable, which prevents the microneedles tips from breaking. The MAE can record EEG signals well in a BIOPAC system and an Emotiv EPOC+ device. The bendable MAE may be an alternative electrode for long-term EEG recording.

11 August 2022 in Chinese Journal of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
BLBin Liu
Bin Liu
XYXin Yi
Xin Yi
YZYing Zheng
Ying Zheng
ZYZhishan Yuan
Zhishan Yuan
JYJingbo Yang
Jingbo Yang
CWChengyong Wang
Chengyong Wang
Needles, as some of the most widely used medical devices, have been effectively applied in human disease prevention, diagnosis, treatment, and rehabilitation. Thin 1D needle can easily penetrate cells/organs by generating highly localized stress with their sharp tips to achieve bioliquid sampling, biosensing, drug delivery, surgery, and other such applications. In this review, we provide an overview of multiscale needle fabrication techniques and their biomedical applications. Needles are classified as nanoneedles, microneedles and millineedles based on the needle diameter, and their fabrication techniques are highlighted. Nanoneedles bridge the inside and outside of cells, achieving intracellular electrical recording, biochemical sensing, and drug delivery. Microneedles penetrate the stratum corneum layer to detect biomarkers/bioelectricity in interstitial fluid and deliver drugs through the skin into the human circulatory system. Millineedles, including puncture, syringe, acupuncture and suture needles, are presented. Finally, conclusions and future perspectives for next-generation nano/micro/milli needles are discussed.

13 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
YSYiwei Sun
Yiwei Sun
LRLei Ren
Lei Ren
Lelun JiangLelun Jiang
Lelun Jiang
YTYong Tang
Yong Tang
BLBin Liu
Bin Liu
Body temperature and bio-signals are important health indicators that reflect the human health condition. However, monitoring these indexes is inconvenient and time-consuming, requires various instruments, and needs professional skill. In this study, a composite microneedle array electrode (CMAE) was designed and fabricated. It simultaneously detects body temperature and bio-signals. The CMAE consists of a 6 × 6 microneedles array with a height of 500 μm and a base diameter of 200 μm. Multiple insertion experiments indicate that the CMAE possesses excellent mechanical properties. The CMAE can pierce porcine skin 100 times without breaking or bending. A linear calibration relationship between temperature and voltage are experimentally obtained. Armpit temperature (35.8 °C) and forearm temperature (35.3 °C) are detected with the CMAE, and the measurements agree well with the data acquired with a clinical thermometer. Bio-signals including EII, ECG, and EMG are recorded and compared with those obtained by a commercial Ag/AgCl electrode. The CMAE continuously monitors bio-signals and is more convenient to apply because it does not require skin preparation and gel usage. The CMAE exhibits good potential for continuous and repetitive monitoring of body temperature and bio-signals.

11 December 2021 in Entropy
Verified
Journal Article
Open access
PDF file
ZLZeming Liu
Zeming Liu
TCTian Chen
Tian Chen
KWKeming Wei
Keming Wei
GLGuanzheng Liu
Guanzheng Liu
BLBin Liu
Bin Liu
Congestive heart failure (CHF) is a chronic cardiovascular condition associated with dysfunction of the autonomic nervous system (ANS). Heart rate variability (HRV) has been widely used to assess ANS. This paper proposes a new HRV analysis method, which uses information-based similarity (IBS) transformation and fuzzy approximate entropy (fApEn) algorithm to obtain the fApEn_IBS index, which is used to observe the complexity of autonomic fluctuations in CHF within 24 h. We used 98 ECG records (54 health records and 44 CHF records) from the PhysioNet database. The fApEn_IBS index was statistically significant between the control and CHF groups (p < 0.001). Compared with the classical indices low-to-high frequency power ratio (LF/HF) and IBS, the fApEn_IBS index further utilizes the changes in the rhythm of heart rate (HR) fluctuations between RR intervals to fully extract relevant information between adjacent time intervals and significantly improves the performance of CHF screening. The CHF classification accuracy of fApEn_IBS was 84.69%, higher than LF/HF (77.55%) and IBS (83.67%). Moreover, the combination of IBS, fApEn_IBS, and LF/HF reached the highest CHF screening accuracy (98.98%) with the random forest (RF) classifier, indicating that the IBS and LF/HF had good complementarity. Therefore, fApEn_IBS effusively reflects the complexity of autonomic nerves in CHF and is a valuable CHF assessment tool.

17 September 2017 in Nanomaterials
Verified
Journal Article
Open access
PDF file
WHWeilong Huang
Weilong Huang
BLBin Liu
Bin Liu
ZCZhipeng Chen
Zhipeng Chen
HWHongjian Wang
Hongjian Wang
LRLei Ren
Lei Ren
Lelun JiangLelun Jiang
Lelun Jiang
Magnetic nanofiber has been widely applied in biomedical fields due to its distinctive size, morphology, and properties. We proposed a novel needleless electrospinning method to prepare magnetic nanofibers from the self-assembling “Taylor cones” of poly(vinyl pyrrolidone) (PVP)/Fe3O4 ferrofluid (PFF) under the coincident magnetic and electric fields. The results demonstrated that a static PFF Rosensweig instability with a conical protrusion could be obtained under the magnetic field. The tip of the protrusion emitted an electrospinning jet under the coincident magnetic and electric fields. The needleless electrospinning showed a similar process phenomenon in comparison with conventional electrospinning. The prepared nanofibers were composed of Fe3O4 particles and PVP polymer. The Fe3O4 particles aggregated inside and on the surface of the nanofibers. The nanofibers prepared by needleless electrospinning exhibited similar morphology compared with the conventionally electrospun nanofibers. The nanofibers also exhibited good ferromagnetic and magnetic field responsive properties.