Deepa Prabhu

Dr. Deepa Prabhu

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DPDeepa Prabhu
Deepa Prabhu
Mahnoosh KholghiMahnoosh Kholghi
Mahnoosh Kholghi
MSMoid Sandhu
Moid Sandhu
WLWei Lu
Wei Lu
KPKatie Packer
Katie Packer
David Silvera-TawilDavid Silvera-Tawil
David Silvera-Tawil
Social isolation (SI) and loneliness are ‘invisible enemies’. They affect older people’s health and quality of life and have significant impact on aged care resources. While in-person screening tools for SI and loneliness exist, staff shortages and psycho-social challenges fed by stereotypes are significant barriers to their implementation in routine care. Autonomous sensor-based approaches can be used to overcome these challenges by enabling unobtrusive and privacy-preserving assessments of SI and loneliness. This paper presents a comprehensive overview of sensor-based tools to assess social isolation and loneliness through a structured critical review of the relevant literature. The aim of this survey is to identify, categorise, and synthesise studies in which sensing technologies have been used to measure activity and behavioural markers of SI and loneliness in older adults. This survey identified a number of feasibility studies using ambient sensors for measuring SI and loneliness activity markers. Time spent out of home and time spent in different parts of the home were found to show strong associations with SI and loneliness scores derived from standard instruments. This survey found a lack of long-term, in-depth studies in this area with older populations. Specifically, research gaps on the use of wearable and smart phone sensors in this population were identified, including the need for co-design that is important for effective adoption and practical implementation of sensor-based SI and loneliness assessment in older adults.

22 January 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
WLWei Lu
Wei Lu
David Silvera-TawilDavid Silvera-Tawil
David Silvera-Tawil
HYHwan-Jin Yoon
Hwan-Jin Yoon
LHLiesel Higgins
Liesel Higgins
Qing ZhangQing Zhang
Qing Zhang
MVMarlien Varnfield
Marlien Varnfield
Background: An increasingly aging population, accompanied by a shortage of residential aged care homes and workforce and consumer feedback, has driven a growing interest in enabling older people to age in place through home-based care. In this context, smart home technologies for remote health monitoring have gained popularity for supporting older people to live in their own homes. Objective: This study aims to investigate the impact of smart home monitoring on multiple outcomes, including quality of life, activities of daily living, and depressive symptoms among older people living in their own homes over a 12-month period. Methods: We conducted an open-label, parallel-group randomized controlled trial. The control group continued to receive their existing care from aged care service providers. Meanwhile, the intervention group, in addition to receiving their usual aged care services, had their activities of daily living monitored using a smart home platform. Surveys including the Adult Social Care Outcomes Toolkit (ASCOT), EuroQol-5 Dimensions-5 Levels (EQ-5D-5L), Katz Index of Independence in Activities of Daily Living (Katz ADL), Lawton Instrumental Activities of Daily Living Scale (IADL), and Geriatric Depression Scale (GDS) were conducted at baseline and 6 and 12 months from baseline. Linear mixed-effects models were used to compare the difference between the intervention and control groups, with the ASCOT as the primary outcome measure. Results: Data from 130 participants were used in the analysis, with no significant differences in baseline characteristics between the control group (n=61) and the intervention group (n=69). In comparison to the control group, the intervention group had a higher ASCOT score at the 6-month assessment (mean difference 0.045, 95% CI 0.001 to 0.089; Cohen d=0.377). However, this difference did not persist at the 12-month assessment (mean difference 0.031, 95% CI –0.014 to 0.076; Cohen d=0.259). There were no significant differences in EQ-5D-5L, Katz ADL, IADL, and GDS observed between the intervention and control groups at the 6-month and 12-month assessments. Conclusions: The study demonstrates that smart home monitoring can improve social care–related quality of life for older people living in their own homes. However, the improvement was not sustained over the long term. The lack of statistically significant findings and diminished long-term improvements may be attributed to the influence of the COVID-19 pandemic during the later stage of the trial. Further research with a larger sample size is needed to evaluate the effect of smart home monitoring on broader quality-of-life measures. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12618000829213; https://tinyurl.com/2n6a75em International Registered Report Identifier (IRRID): RR2-10.2196/31970

1 January 2018
Verified
Book Chapter
Closed access
PDF file
ABAnn Borda
Ann Borda
GCGilbert Cecily
Gilbert Cecily
GKGray Kathleen
Gray Kathleen
DPDeepa Prabhu
Deepa Prabhu
Background: The present study was undertaken to build an evidence base focusing on an ageing population who are using or have used consumer wearables to collect and manage information about their personal health status. The primary objective was to understand the health self-management requirements, frailty and age related changes, and the health information support provided by consumer wearable devices, specifically in the context of older adults living independently.

10 January 2026 in International Journal of Medical Informatics
Verified
Journal Article
Open access
MSMoid Sandhu
Moid Sandhu
SLSiddique Latif
Siddique Latif
ABAndrew Bayor
Andrew Bayor
WLWei Lu
Wei Lu
Mahnoosh KholghiMahnoosh Kholghi
Mahnoosh Kholghi
David Silvera-TawilDavid Silvera-Tawil
David Silvera-Tawil
This paper critically reviews existing work in sensor-based emotional dysregulation monitoring to support caregivers of individuals diagnosed with autism spectrum disorder (ASD). A systematic literature search was conducted across six databases (Google Scholar, IEEE Xplore, Scopus, ACM Digital Library, Web of Science, and PubMed) covering publications from January 1, 2016, to September 30, 2025. Thirty-two studies met inclusion criteria, comprising 27 focused on sensor-based emotional dysregulation detection and 5 addressing intervention or support mechanisms. These studies suggest that sensor-based technologies have potential for continuous physiological monitoring, facilitating early detection and intervention to support emotional dysregulation episodes. Critical deficiencies were identified in real-time alerting capabilities, autonomous intervention deployment, self-regulation framework integration, system reliability, long-term sustainability, user interface design, and cross-environment scalability. There is a significant need to develop real-time emotion monitoring systems to empower caregivers in delivering timely, targeted interventions for individuals diagnosed with ASD. Future research should prioritise the development of real-time alert systems, autonomous intervention protocols, and solutions optimised for reliability, sustainability, usability, and adaptability across heterogeneous care settings.

1 January 2012
Verified
Book Chapter
Closed access
PDF file
DPDeepa Prabhu
Deepa Prabhu
MKMohanavelu K.
Mohanavelu K.
SBSundersheshu B.S.
Sundersheshu B.S.
PVPadaki V.C.
Padaki V.C.

4 February 2021 in Engineering Research Express
Verified
Journal Article
Closed access
PDF file
DPDeepa Prabhu
Deepa Prabhu
LWLisa Wise
Lisa Wise
CMClare MacMahon
Clare MacMahon
MMMarten De Man
Marten De Man
MPMatthew Petoe
Matthew Petoe
CMChris McCarthy
Chris McCarthy
Objective: The positioning of the external camera in current designs of retinal prostheses may affect the egocentric spatial frame of reference and lead to pointing and localisation errors. The present simulated prosthetic vision (SPV) study investigated the immediate effects of four camera positions: (i) centre-mounted (CM), (ii) head-mounted (HM), (iii) left-mounted (LM), (iv) right-mounted (RM) on egocentric localisation. Approach: Fifteen sighted participants performed a pointing task while viewing the stimulus through a simulation of Bionic Vision Technologies’ 44-channel retinal prosthesis. Pointing responses were recorded immediately after exposure to different camera positions and prior to adaptation. The direction and magnitude of pointing errors and associated head movement behaviour were analysed using linear mixed effects analysis. Main results: Our results showed lower errors for medial camera positions (CM and HM) and overall improved accuracy and precision for CM position. Head orientation was found to largely influence the direction of pointing. There was a high positive correlation between direction of head orientation and direction of pointing with CM and HM camera positions, suggesting medial camera positions facilitated intuitive head orientation cues that are important for reliable egocentric direction estimation. Significance: The empirical evidence derived from the present SPV study offers practical guidance to reduce the effect on spatial dissociation of camera position in localisation tasks and inform design of future prosthetic vision devices and improve rehabilitation approaches.