Falls are the number one cause of injuries in the elderly. A wearable fall detector can automatically detect the occurrence of a fall and alert a caregiver or a medical rescue group for immediate assistance, mitigating fall-related injuries. However, most studies on fall detection to date have focused on the accuracy of detection while neglecting power efficiency and battery life, and hence the developed fall detectors usually cannot operate for a long period (a year or more) without recharging or replacing their batteries. This paper presents a low-power fall detector that utilizes triaxial accelerometry and barometric pressure sensing. This fall detector reduces its power consumption through both hardware- and firmware-based approaches. This study also incorporates several human trials to develop and evaluate the device, including simulated falls and activities of daily living. A benchtop power measurement test is also conducted to estimate the battery life with data from a one-week free-living trial. These experiments show that the fall detector achieves high sensitivity (97.5% and 93.0%) and specificity (93.2% and 87.3%) on training and testing datasets, while providing an estimated battery life of 664.9 days.
Falls in older people are a major challenge to public health. A wearable fall detector can detect falls automatically based on kinematic information of the human body, allowing help to arrive sooner. To date, most studies have focused on the accuracy of an offline algorithm to distinguish real-world or simulated falls from activities of daily living, while neglecting the false alarm rate and battery life of a real device. To address these two important metrics which significantly influence user compliance, this paper proposes a low-power fall detector using triaxial accelerometry and barometric pressure sensing. This fall detector minimizes power consumption using both hardware- and firmware-based techniques. Additionally, the fall detection algorithm used in this device is optimized to achieve a balance between sensitivity and false alarm rate, while minimizing the power consumption due to algorithm execution. The fall detector achieved a high sensitivity (91%) with a low false alarm rate (0.1149 alarms per hour), and a commercially-viable battery life (1,125 days).
Social isolation (SI) and loneliness are ‘invisible enemies’. They affect older people’s health and quality of life and have significant impact on aged care resources. While in-person screening tools for SI and loneliness exist, staff shortages and psycho-social challenges fed by stereotypes are significant barriers to their implementation in routine care. Autonomous sensor-based approaches can be used to overcome these challenges by enabling unobtrusive and privacy-preserving assessments of SI and loneliness. This paper presents a comprehensive overview of sensor-based tools to assess social isolation and loneliness through a structured critical review of the relevant literature. The aim of this survey is to identify, categorise, and synthesise studies in which sensing technologies have been used to measure activity and behavioural markers of SI and loneliness in older adults. This survey identified a number of feasibility studies using ambient sensors for measuring SI and loneliness activity markers. Time spent out of home and time spent in different parts of the home were found to show strong associations with SI and loneliness scores derived from standard instruments. This survey found a lack of long-term, in-depth studies in this area with older populations. Specifically, research gaps on the use of wearable and smart phone sensors in this population were identified, including the need for co-design that is important for effective adoption and practical implementation of sensor-based SI and loneliness assessment in older adults.
15 February 2017 in IEEE Transactions on Biomedical Engineering
Falls are a serious threat to the health of older people. A wearable fall detector can automatically detect the occurrence of a fall and alert a caregiver or an emergency response service so they may deliver immediate assistance, improving the chances of recovering from fall-related injuries. One constraint of such a wearable technology is its limited battery life. Thus, minimization of power consumption is an important design concern, all the while maintaining satisfactory accuracy of the fall detection algorithms implemented on the wearable device. This paper proposes an approach for selecting power-efficient signal features such that the minimum desirable fall detection accuracy is assured. Using data collected in simulated falls, simulated activities of daily living, and real free-living trials, all using young volunteers, the proposed approach selects four features from a set of ten commonly used features, providing a power saving of 75.3%, while limiting the error rate of a binary classification decision tree fall detection algorithm to 7.1%.Falls are a serious threat to the health of older people. A wearable fall detector can automatically detect the occurrence of a fall and alert a caregiver or an emergency response service so they may deliver immediate assistance, improving the chances of recovering from fall-related injuries. One constraint of such a wearable technology is its limited battery life. Thus, minimization of power consumption is an important design concern, all the while maintaining satisfactory accuracy of the fall detection algorithms implemented on the wearable device. This paper proposes an approach for selecting power-efficient signal features such that the minimum desirable fall detection accuracy is assured. Using data collected in simulated falls, simulated activities of daily living, and real free-living trials, all using young volunteers, the proposed approach selects four features from a set of ten commonly used features, providing a power saving of 75.3%, while limiting the error rate of a binary classification decision tree fall detection algorithm to 7.1%.
Background: An aging population, accompanied by the prevalence of age-related diseases, presents a significant burden to health systems. This is exacerbated by an increasing shortage of aged care staff due to the existing workforce entering their retirement and fewer young people being attracted to work in aged care. In line with consumer preferences and potential cost-efficiencies, government and aged care providers are increasingly seeking options to move care and support to the community or home as opposed to residential care facilities. However, compared to residential care, home environments may provide limited opportunity for monitoring patients’ progression/decline in functioning and therefore limited opportunity to provide timely intervention. To address this, the Smarter Safer Homes (SSH) platform was designed to enable self-monitoring and/or management, and to provide aged care providers with support to deliver their services. The platform uses open Internet of Things communication protocols to easily incorporate commercially available sensors into the system. Objective: Our research aims to detail the benefits of utilizing the SSH platform as a service in its own right as well as a complementary service to more traditional/historical service offerings in aged care. This work is anticipated to validate the capacity and benefits of the SSH platform to enable older people to self-manage and aged care service providers to support their clients to live functionally and independently in their own homes for as long as possible. Methods: This study was designed as a single-blinded, stratified, 12-month randomized controlled trial with participants recruited from three aged care providers in Queensland, Australia. The study aimed to recruit 200 people, including 145 people from metropolitan areas and 55 from regional areas. Participants were randomized to the intervention group (having the SSH platform installed in their homes to assist age care service providers in monitoring and providing timely support) and the control group (receiving their usual aged care services from providers). Data on community care, health and social-related quality of life, health service utilization, caregiver burden, and user experience of both groups were collected at the start, middle (6 months), and end of the trial (12 months). Results: The trial recruited its first participant in April 2019 and data collection of the last participant was completed in November 2020. The trial eventually recruited 195 participants, with 98 participants allocated to the intervention group and 97 participants allocated to the control group. The study also received participants’ health service data from government data resources in June 2021. Conclusions: A crisis is looming to support the aging population. Digital solutions such as the SSH platform have the potential to address this crisis and support aged care in the home and community. The outcomes of this study could improve and support the delivery of aged care services and provide better quality of life to older Australians in various geographical locations. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12618000829213; https://tinyurl.com/2n6a75em International Registered Report Identifier (IRRID): DERR1-10.2196/31970