Jelena Krneta Nikolic

Dr. Jelena Krneta Nikolic

Radiation and Environmental Protection Department, Institute of Nuclear Sciences "Vinča" National Institute for the Republic of Serbia, University of Belgrade, Belgrade, Beograd, Serbia
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2011 in Environmental Science & Technology
Verified
Journal Article
Closed access
OMO. Masson
O. Masson
ABA. Baeza
A. Baeza
JBJ. Bieringer
J. Bieringer
KBK. Brudecki
K. Brudecki
SBS. Bucci
S. Bucci
OZO. Zhukova
O. Zhukova

ICIgor Celikovic
Igor Celikovic
GPGordana Pantelić
Gordana Pantelić
IVIvana Vukanac
Ivana Vukanac
JNJelena Krneta Nikolic
Jelena Krneta Nikolic
MŽMilos Živanović
Milos Živanović
Daniel RábagoDaniel Rábago
Daniel Rábago
Doses from the exposure to outdoor radon are typically an order of magnitude smaller than those from indoor radon, causing a greater interest on investigation of the latter for radiation protection issues. As a consequence, assessment of radon priority areas (RPA) is mainly based on indoor radon measurements. Outdoor radon measurements might be needed to guarantee a complete estimation of radiological risk and may help to improve the estimation of RPA. Therefore, authors have analysed the available literature on outdoor radon to give an overview of outdoor radon surveys and potential correlation with indoor radon and estimation of RPA. The review has shown that outdoor radon surveys were performed at much smaller scale compared to indoor radon. Only a few outdoor radon maps were produced, with a much smaller density, covering a larger area, and therefore putting doubt on the representativeness of this data. Due to a large variety of techniques used for outdoor radon measurements and requirement to have detectors with a high sensitivity and resistance to harsh environmental conditions, a standardised measurement protocol should be derived. This is no simple endeavour since there are more applications in different scientific disciplines for outdoor radon measurements compared to indoor radon.

1 January 2011 in Journal of Mining and Metallurgy, Section B: Metallurgy
Verified
Journal Article
Open access
PDF file
MJMarija Jankovic
Marija Jankovic
DTD.J. Todorovic
D.J. Todorovic
JNJelena Krneta Nikolic
Jelena Krneta Nikolic
The radioactivity monitoring in the ?Nikola Tesla?, ?Kolubara?, ?Morava? and ?Kostolac? coal-fired power plants was performed by the Radiation and Environmental Protection Laboratory, Vinca Institute of nuclear sciences in the period 2003-2010. Monitoring included the analysis of soil, water, flying ash, slag, coal and plants. This paper presents the results of the radioactivity analysis of coal, ash and slag samples. Naturally occurring radionuclides 226Ra, 232Th, 40K, 235U, 238U, and 210Pb as well as the man-made radionuclide 137Cs were determined by gamma spectrometry using HPGe detector. The concentrations of pairs of radionuclides were statistically tested to determine the correlation between them. Based on the obtained results, health effect due to the activity of these radionuclides was estimated via radium equivalent (Raeq), external hazard index (Hex), external gamma absorbed dose rate () and annual effective dose.

1 November 2014 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
JNJelena Krneta Nikolic
Jelena Krneta Nikolic
TVTim Vidmar
Tim Vidmar
DJDejan Jokovic
Dejan Jokovic
MRMilica Rajacic
Milica Rajacic
DTDragana Todorovic
Dragana Todorovic

29 November 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ICIgor Celikovic
Igor Celikovic
GPGordana Pantelić
Gordana Pantelić
IVIvana Vukanac
Ivana Vukanac
JNJelena Krneta Nikolic
Jelena Krneta Nikolic
MŽMilos Živanović
Milos Živanović
Daniel RábagoDaniel Rábago
Daniel Rábago
Radon flux measurements provide information about how much radon rises from the ground toward the atmosphere, thus, they could serve as good predictors of indoor radon concentrations. Although there are many different mapping methods with many different input data, radon flux data are generally missing and are not included for the delineation of radon priority areas (RPA). The aim of this literature review is to investigate to what extent radon flux was used, or could be used, for the delineation of RPAs. Numerous factors influencing radon flux were identified, but quantifying their contribution to radon flux measurement still remains a challenge. Different methods and measuring devices were used for the determination of radon flux, thus it is necessary to identify possible inconsistencies in order to harmonise different radon flux measurements. Due to the complexity of radon flux measurements, only two countries were identified to have performed national surveys on outdoor radon, which were of much smaller scale compared to those on indoor radon. A positive correlation between radon flux and radon quantities, such as radon in soil gas and indoor radon, indicates that radon flux could be used as an input parameter for the estimation of RPA. By reviewing radon flux models, it was concluded that up-to-date modelled radon flux maps have reached excellent spatial resolution and will be further improved, hence, they could serve as an input for the estimation and delineation of RPA.

1 November 2014 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
GPGordana K. Pantelić
Gordana K. Pantelić
DTDragana J. Todorović
Dragana J. Todorović
JNJelena Krneta Nikolic
Jelena Krneta Nikolic
MRMilica M. Rajačić
Milica M. Rajačić
MJMarija Jankovic
Marija Jankovic
NSNataša Sarap
Nataša Sarap