Doses from the exposure to outdoor radon are typically an order of magnitude smaller than those from indoor radon, causing a greater interest on investigation of the latter for radiation protection issues. As a consequence, assessment of radon priority areas (RPA) is mainly based on indoor radon measurements. Outdoor radon measurements might be needed to guarantee a complete estimation of radiological risk and may help to improve the estimation of RPA. Therefore, authors have analysed the available literature on outdoor radon to give an overview of outdoor radon surveys and potential correlation with indoor radon and estimation of RPA. The review has shown that outdoor radon surveys were performed at much smaller scale compared to indoor radon. Only a few outdoor radon maps were produced, with a much smaller density, covering a larger area, and therefore putting doubt on the representativeness of this data. Due to a large variety of techniques used for outdoor radon measurements and requirement to have detectors with a high sensitivity and resistance to harsh environmental conditions, a standardised measurement protocol should be derived. This is no simple endeavour since there are more applications in different scientific disciplines for outdoor radon measurements compared to indoor radon.
1 July 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
The aim of this study was determination of physical-chemical and radiological characteristics of kaolin and products of alkali-activated thermally treated kaolin (geopolymer). Also, the objective of presented research was to investigate the possibility of kaolin application as a pigment or as a raw material for obtaining geopolymer materials as a relatively new ones in a building material industry. Physicochemical characterization of one set of samples was conducted using X-ray diffraction (XRD), Fourier transform infra - red (FTIR) and X-ray photoelectron spectroscopy (XPS). Activity concentration of naturally occurring radionuclides in kaolin, metakaolin and geopolymer were determined. The absorbed dose rate (D) and the annual effective dose rate (EDR), calculated in accordance with the UNSCEAR 2000 report, are also presented in this paper. Kaolin was heat-treated on 750oC and specific activity of natural radionuclide in metakaolin increased up to 1.6, while measured specific activities in geopolymer were the lowest.
1 November 2016 in Journal of Environmental Radioactivity