Ruyue Liu

Dr. Ruyue Liu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2023 in Structures
Verified
Journal Article
Closed access
LXLi Xu
Li Xu
HHHong-Song Hu
Hong-Song Hu
YLYan-Ting Lan
Yan-Ting Lan
Ruyue LiuRuyue Liu
Ruyue Liu
HXHao-Jian Xia
Hao-Jian Xia

17 August 2020 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Ruyue LiuRuyue Liu
Ruyue Liu
YYYong Yang
Yong Yang

10 June 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
Ruyue LiuRuyue Liu
Ruyue Liu
JWJianbin Wu
Jianbin Wu
GYGuiyun Yan
Guiyun Yan
QLQiulan Lai
Qiulan Lai
HWHao Wang
Hao Wang

30 August 2023 in The Structural Design of Tall and Special Buildings
Verified
Journal Article
Closed access
JWJianbin Wu
Jianbin Wu
Ruyue LiuRuyue Liu
Ruyue Liu
GYGuiyun Yan
Guiyun Yan
QLQiulan Lai
Qiulan Lai

17 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YNYanbin Ni
Yanbin Ni
XLXiancheng Liu
Xiancheng Liu
YCYahui CHEN
Yahui CHEN
Ruyue LiuRuyue Liu
Ruyue Liu
Incorporating geopolymeric recycled brick aggregate concrete into steel tubes provides a promising solution to reduce environmental impact of construction and demolition waste. In this paper, geopolymeric recycled brick aggregate concrete-filled steel tubular column (GRBACFST) was developed to improve the environmental sustainability of composite column. Considering the replacement ratio of recycled brick aggregate (RBA), the thickness of the steel tube, type of cementitious materials and the axial compression ratio as the variation parameters, experimental research was performed to explore the cyclic behavior of GRBACFST columns, including the failure mode, bearing capacity, hysteresis curve, ductility and degradation characteristics. Results demonstrated that the failure of GRBACFST columns occurred in the region at column bottom, with the bulge of steel tube and crush of geopolymeric recycled brick aggregate concrete. The proposed GRBACFST columns exhibited favorable hysteretic behaviors with desired bearing capacity, excellent ductility, and energy dissipation behavior, which were enhanced by the increased thickness of the steel tube. The bearing capacity and ductility were reduced with the increase of axial compression ratio, while enhanced with thicker steel tube. Moreover, the degradation of stiffness and strength was more obvious under larger axial compression ratio. The increase of replacement ratio of RBA caused a significant reduction of bearing capacity, while it had few effect on the hysteretic index. It was concluded that the hysteretic behavior of proposed GRBACFST column was not sensitive to the types of cementitious material and geopolymers could serve as an eco-friendly binder for concrete.

6 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XGXian Gao
Xian Gao
SLShaoyuan Lin
Shaoyuan Lin
Ruyue LiuRuyue Liu
Ruyue Liu
XCXilong Chen
Xilong Chen
Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control. The beam–column joint is the essential constitutive part to ensure structural integrity and reliable force transmission for the prefabricated structure. In this paper, a novel load bearing-energy dissipation connection is proposed and applied to the beam–column joint to improve seismic performance and seismic resilience. Pseudo-static tests were conducted on the beam–column joint with the load bearing-energy dissipation connection, and the test results demonstrated that the tested beam–column joints developed with similar failure modes, and the damage was concentrated in the load bearing-energy dissipation connection while the beam and column remained elastic. The beam–column joint with the load bearing-energy dissipation connection had stable hysteresis behavior, with favorable bearing capacity and energy dissipation behavior. A shorter slip length and a larger bolt distance could lead to better stress development and enhance the bearing capacity, while the slip length barely affected the ductile behavior. Moreover, a finite element model was established and validated to extend the parametric study to provide a preliminary understanding of the mechanical mechanism of the proposed beam–column joint with the load bearing-energy dissipation connection. It was confirmed that the load–-deformation behavior was greatly affected by the slip length, but the slip length barely affected the initial stiffness. The width of the sliding steel fuse influenced the bearing capacity and the degradation behavior. A wider width could lead to a higher bearing capacity and improve the degradation behavior. Based on the analysis of the stress development and stress distribution corresponding to different feature points, it was concluded that the use of bearing-energy dissipation improved the stress development in the framing components and achieved damage concentration.