Xilong Chen

Mr. Xilong Chen


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2025 in CivilEng
Verified
Journal Article
Open access
PDF file
XGXian Gao
Xian Gao
XCXilong Chen
Xilong Chen
Kun LuKun Lu
Kun Lu
XDXueyuan Deng
Xueyuan Deng
Although prefabricated buildings offer environmental advantages, their construction process inevitably generates environmental impacts. However, current research on prefabricated buildings focuses on the environmental impact level, and there is a lack of intelligent tools for analyzing their spatial and temporal dimensions. Therefore, this study develops a framework using 5D building information modeling (BIM) to monetize environmental impacts into environmental costs for prefabricated building construction. This framework includes defining boundaries and indicators, obtaining a resource inventory using the 5D BIM coding system, calculating environmental impact results, and converting environmental impacts into environmental costs. Taking a prefabricated substation as a case study, its environmental costs are 172.81 CNY/m2, with these costs caused by climate change accounting for the largest proportion (91.2%). This study unifies different environmental impacts into a single monetary form, providing stakeholders with intuitive indicators. It also expands 5D BIM applications from conventional costs to environmental costs, which can display their spatiotemporal changes.

18 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
Weihua WangWeihua Wang
Weihua Wang
TZTao Zhu
Tao Zhu
XGXian Gao
Xian Gao
JYJingjie Yang
Jingjie Yang
XCXilong Chen
Xilong Chen
WWWeiyong Wang
Weiyong Wang
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the fire resistance testing of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral–torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation.

24 July 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XCXilong Chen
Xilong Chen
XGXian Gao
Xian Gao
LXLi Xu
Li Xu
JZJian-Wen Zhao
Jian-Wen Zhao
LZLianqiong Zheng
Lianqiong Zheng
Based on the need to enhance the seismic performance of point-supported steel frame precast cladding panel systems, this study proposes a novel friction-energy-dissipating connection joint. Through establishing refined finite element models, low-cycle reversed loading analyses and elastoplastic time-history analyses were conducted on three frame systems. These included a benchmark bare frame and two cladding-panel-equipped frame structures configured with energy-dissipating joints using different specifications of high-strength bolts (M14 and M20, respectively). The low-cycle reversed loading results demonstrate that the friction energy dissipation of the novel joints significantly improved the seismic performance of the frame structures. Compared to the bare frame, the frames equipped with cladding panels using M14 bolts demonstrated 10.9% higher peak lateral load capacity, 17.6% greater lateral stiffness, and 45.6% increased cumulative energy dissipation, while those with M20 bolts showed more substantial improvements of 22.8% in peak load capacity, 32.0% in lateral stiffness, and 64.2% in cumulative energy dissipation. The elastoplastic time-history analysis results indicate that under seismic excitation, the maximum inter-story drift ratios of the panel-equipped frames with M14 and M20 bolts were reduced by 42.7% and 53%, respectively, compared to the bare frame. Simultaneously, the equivalent plastic strain in the primary structural members significantly decreased. Finally, based on the mechanical equilibrium conditions, a calculation formula was derived to quantify the contribution of joint friction to the horizontal load-carrying capacity of the frame.

6 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XGXian Gao
Xian Gao
SLShaoyuan Lin
Shaoyuan Lin
Ruyue LiuRuyue Liu
Ruyue Liu
XCXilong Chen
Xilong Chen
Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control. The beam–column joint is the essential constitutive part to ensure structural integrity and reliable force transmission for the prefabricated structure. In this paper, a novel load bearing-energy dissipation connection is proposed and applied to the beam–column joint to improve seismic performance and seismic resilience. Pseudo-static tests were conducted on the beam–column joint with the load bearing-energy dissipation connection, and the test results demonstrated that the tested beam–column joints developed with similar failure modes, and the damage was concentrated in the load bearing-energy dissipation connection while the beam and column remained elastic. The beam–column joint with the load bearing-energy dissipation connection had stable hysteresis behavior, with favorable bearing capacity and energy dissipation behavior. A shorter slip length and a larger bolt distance could lead to better stress development and enhance the bearing capacity, while the slip length barely affected the ductile behavior. Moreover, a finite element model was established and validated to extend the parametric study to provide a preliminary understanding of the mechanical mechanism of the proposed beam–column joint with the load bearing-energy dissipation connection. It was confirmed that the load–-deformation behavior was greatly affected by the slip length, but the slip length barely affected the initial stiffness. The width of the sliding steel fuse influenced the bearing capacity and the degradation behavior. A wider width could lead to a higher bearing capacity and improve the degradation behavior. Based on the analysis of the stress development and stress distribution corresponding to different feature points, it was concluded that the use of bearing-energy dissipation improved the stress development in the framing components and achieved damage concentration.

21 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Weihua WangWeihua Wang
Weihua Wang
涛朱涛 朱
涛 朱
XGXian Gao
Xian Gao
JYJingjie Yang
Jingjie Yang
XCXilong Chen
Xilong Chen
WWWeiyong Wang
Weiyong Wang
Fire safety design for steel beams is crucial in the construction of steel structures. However, there remains a significant gap in the testing of the fire resistance of insulated steel beams. This study focuses on full-scale experimental research examining the fire resistance performance of steel beams with varying fire protection methods, cross-sectional dimensions, and heating curves. During the tests, the furnace temperature, specimen temperature, and deflection at mid-span were measured. The test results indicated that specimens mainly failed in lateral-torsional buckling. Additionally, a markedly non-uniform temperature distribution was observed across the cross-section, and the predictions made by GB 51249-2017 were found to be unsafe. The use of fiber cement board for fire protection may be ineffective, as it tends to become brittle at elevated temperatures, making it susceptible to breakage and detachment when the beams begin to bend. Furthermore, due to potential creep deformation, specimens subjected to longer heating durations exhibited lower critical temperatures compared to those with shorter heating durations. Finally, the design method outlined in BS EN 1993-1-2 and ANSI/AISC 360-22 was evaluated against the test results, indicating an accurate prediction of these methods for specimens with shorter heating durations, but an unconservative prediction for specimens with longer heating durations due to ignorance of creep deformation.

1 September 2025 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
XGXian Gao
Xian Gao
XCXilong Chen
Xilong Chen
YRYu Ren
Yu Ren
JLJie Li
Jie Li
ZLZhenshan Lin
Zhenshan Lin
JZJinping Zhuang
Jinping Zhuang
Steel fiber reinforced self-compacting concrete exhibits favorable characteristics of ductility and fluidity, making it a popular choice for structural reinforcement and cast-in-place connection of concrete structures. To assess the bond properties between steel fiber reinforced self-compacting concrete and conventional concrete, direct shear tests were conducted on 7 sets of Z-shaped specimens, with varying parameters such as the reinforcement rate, groove depth. All specimens exhibited failure at the bonding surface, with unreinforced specimens displaying predominantly brittle failure, while reinforced specimens demonstrated certain ductility. The presence of steel fibers contributes to shear resistance, particularly in grooved bonding surfaces. As the reinforcement rate, groove depth increase, the shear capacity of the bonded surface also increases.