Bingfang Xie

Ms. Bingfang Xie

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BXBingfang Xie
Bingfang Xie
XTXiaocong Tang
Xiaocong Tang
Cong WangCong Wang
Cong Wang
QWQun Wu
Qun Wu
This study introduced two devices for detecting the concentration of glucose in aqueous solutions. To enhance robustness and reduce tolerance, a differential method was employed. Initially, a basic sensor based on a defected ground structure (DGS) was designed. To optimize the performance of the microwave sensor, the squares of the DGS were optimized using an adaptive genetic algorithm. The performance enhancement was demonstrated through the difference in resonant frequencies and improved electric field distribution. The use of glass microcapillary tubes allowed for non-invasive sample handling. The sensitivity of the optimized device is more than 1.6 times that of the basic structure, reaching 5.63 MHz/mgmL -1 . And the experiment showed that the frequency shift response of the sensor to a 3.6 mg/mL glucose solution remained almost unchanged in the temperature range of 20-40 °C, which proved that the sensor can avoid the influence of temperature. Subsequently, an integrated system was developed to directly display the concentration results, providing consistent readings from the sensors. The system demonstrated a response time of within 2 s, indicating real-time detection capabilities for glucose sensing.

29 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BXBingfang Xie
Bingfang Xie
ZGZhiqiang Gao
Zhiqiang Gao
Cong WangCong Wang
Cong Wang
LALuqman Ali
Luqman Ali
AMAzeem Muhammad
Azeem Muhammad
QWQun Wu
Qun Wu
This paper presents two devices to detect the liquid dielectric characterization. The differential method was used to enhance the robustness and reduce tolerance. A basic sensor based on defected ground structure (DGS) was designed and the optimization for the squares of the DGS via adaptive genetic algorithm was applied to enhance the performance of the microwave sensor, which was shown by the difference of the two resonant frequencies. Furthermore, the electric field distribution was enhanced. Glass microcapillary tubes were used to hold samples to provide an environment of non-invasive. The optimized device exhibited the sensitivity of 0.076, which is more than 1.52 times than the basic structure. It could be considered a sensitive and robust sensor with quick response time for liquid dielectric characterization.

2 December 2022 in Microwave and Optical Technology Letters
Verified
Journal Article
Closed access
BXBingfang Xie
Bingfang Xie
CWCong Wang
Cong Wang
FMFanyi Meng
Fanyi Meng
XLXiao Li
Xiao Li
QWQun Wu
Qun Wu

2 October 2020 in Journal of Electromagnetic Waves and Applications
Verified
Journal Article
Closed access
BXBingfang Xie
Bingfang Xie
Cong WangCong Wang
Cong Wang
AKAlok Kumar
Alok Kumar
QWQun Wu
Qun Wu
MZMeng Zhao
Meng Zhao
This paper presents an ultra-wideband and highly miniaturized dual-mode Wilkinson power divider fabricated using thin film integrated passive device (TFIPD) technology for GSM band (0.9 GHz). The four quarter-wavelength lines of conventional two-section Wilkinson power divider are replaced with π-type transformer. In addition, a RC filter is introduced at the input port to minimize the return loss. The presented power divider prototype is micro-fabricated on a gallium arsenide (GaAs) substrate through TFIPD technology to reduce overall structure size and minimize overall parasitic losses. The fabricated power divider exhibits compact size at central frequency of 0.9 GHz with an ultra-wideband working bandwidth. To the best of authors’ knowledge, the designed power divider is approximately 8 times smaller than the previously reported power dividers.