Zhiqiang Gao

Dr. Zhiqiang Gao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ZGZhiqiang Gao
Zhiqiang Gao
LALuqman Ali
Luqman Ali
Cong WangCong Wang
Cong Wang
Ruizhi LiuRuizhi Liu
Ruizhi Liu
CWChunwei Wang
Chunwei Wang
FMFanyi Meng
Fanyi Meng
In this paper, the extraction of the life activity spectrum based on the millimeter (mm) wave radar is designed to realize the detection of target objects and the threshold trigger module. The maximum likelihood estimation method is selected to complete the design of the average early warning probability trigger function. The threshold trigger module is designed for the echo signal of static objects in the echo signal. It will interfere with the extraction of Doppler frequency shift results. The moving target detection method is selected, and the filter is designed. The static clutter interference is filtered without affecting the phase difference between the detection sequences, and the highlight target signal is improved. The frequency and displacement of thoracic movement are used as the detection data. Through the Fourier transform calculation of the sequence, the spectrum value is extracted within the estimated range of the heartbeat and respiration spectrum, and the heartbeat and respiration signals are picked up. The proposed design uses Modelsim and Quartus for CO-simulation to complete the simulation verification of the function, extract the number of logical units occupied by computing resources, and verify the algorithm with the vital signs experiment. The heartbeat and respiration were detected using the sports bracelet; the relative errors of heartbeat detection were 0–6.3%, the respiration detection was 0–9.5%, and the relative errors of heartbeat detection were overwhelmingly less than 5%.

11 August 2022 in Nanoscale
Verified
Journal Article
Closed access
PDF file
ZLZheyi Li
Zheyi Li
ZGZhiqiang Gao
Zhiqiang Gao
Cong WangCong Wang
Cong Wang
DZDanqing Zou
Danqing Zou
HZHuan Zhou
Huan Zhou
Lei WangLei Wang
Lei Wang
Janus nanoparticles, with unique structure and properties, exhibit great advantages in bioimaging field, such as optical imaging, magnetic resonance imaging, computed tomography imaging, etc., which was timely and concisely discussed in this paper.

20 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XTXiaocong Tang
Xiaocong Tang
ZGZhiqiang Gao
Zhiqiang Gao
JWJie Wei
Jie Wei
ZLZheyi Li
Zheyi Li
YYYang Yi
Yang Yi
Cong WangCong Wang
Cong Wang
In this work, a microwave resonator sensor with a unique configuration consisting of three resonators and two feedlines is proposed. This novel design aims to improve the performance and functionality of microwave resonator sensors for various applications. The frequency response of the sensor to materials with different dielectric constants is simulated. The results show that the most sensitive region of the sensor is located on the first interdigital structure, and placing the materials in other regions would enhance the linear correlation of its frequency response. The sensor also exhibits the ability to distinguish whether the same material has defects and the ability to qualitatively detect subtle changes in dielectric constant. Finally, the proposed sensor is fabricated and measured under the condition consistent with the simulation environment. The measured results are basically consistent with the simulation results, which confirms the potential of this sensor in detecting dielectric constants and resolving materials with defects, and the response of the sensor to the materials under test demonstrates its potential in measuring different thicknesses and loss tangents.

28 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JWJie Wei
Jie Wei
MZMeng Zhao
Meng Zhao
Cong WangCong Wang
Cong Wang
JWJun Wang
Jun Wang
JYJian-Min Ye
Jian-Min Ye
Ju GaoJu Gao
Ju Gao
Gas sensing performance characterization systems are essential for the research and development of gas sensing materials and devices. Although existing systems are almost completely automatically operated, the accuracies of gas concentration control and of pressure control and the ability to simultaneously detect different sensor signals still require improvement. In this study, a high-precision gas sensing material characterization system is developed based on vacuum technology, with the objective of enabling the precise and simultaneous measurement of electrical responses. Because of the implementation of vacuum technology, the gas concentration control accuracy is improved more than 1600 times, whereas the pressure of the test ambient condition can be precisely adjusted between vacuum and 1.2 bar. The vacuum-assisted gas-exchanging mechanism also enables the sensor response time to be determined more accurately. The system is capable of performing sensitivity, selectivity, and stability tests and can control the ambient relative humidity in a precise manner. More importantly, the levels of performance of three different optical signal measurement set-ups were investigated and compared in terms of detection range, linearity, noise, and response time, based on which of their scopes of application were proposed. Finally, single-period and cyclical tests were performed to examine the ability of the system to detect optical and electrical responses simultaneously, both at a single wavelength and in a spectral region.

29 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BXBingfang Xie
Bingfang Xie
ZGZhiqiang Gao
Zhiqiang Gao
Cong WangCong Wang
Cong Wang
LALuqman Ali
Luqman Ali
AMAzeem Muhammad
Azeem Muhammad
QWQun Wu
Qun Wu
This paper presents two devices to detect the liquid dielectric characterization. The differential method was used to enhance the robustness and reduce tolerance. A basic sensor based on defected ground structure (DGS) was designed and the optimization for the squares of the DGS via adaptive genetic algorithm was applied to enhance the performance of the microwave sensor, which was shown by the difference of the two resonant frequencies. Furthermore, the electric field distribution was enhanced. Glass microcapillary tubes were used to hold samples to provide an environment of non-invasive. The optimized device exhibited the sensitivity of 0.076, which is more than 1.52 times than the basic structure. It could be considered a sensitive and robust sensor with quick response time for liquid dielectric characterization.

9 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HLHeng Liu
Heng Liu
MZMeng Zhao
Meng Zhao
YGYongkang Gong
Yongkang Gong
KLKang Li
Kang Li
Cong WangCong Wang
Cong Wang
Ju GaoJu Gao
Ju Gao
In this study, a multifunctional high-vacuum system was established to measure the electro-optical conversion efficiency of metamaterial-based thermal emitters with built-in heaters. The system is composed of an environmental control module, an electro-optical conversion measurement module, and a system control module. The system can provide air, argon, high vacuum, and other conventional testing environments, combined with humidity control. The test chamber and sample holder are carefully designed to minimize heat transfer through thermal conduction and convection. The optical power measurements are realized using the combination of a water-cooled KBr flange, an integrating sphere, and thermopile detectors. This structure is very stable and can detect light emission at the μW level. The system can synchronously detect the heating voltage, heating current, optical power, sample temperatures (both top and bottom), ambient pressure, humidity, and other environmental parameters. The comprehensive parameter detection capability enables the system to monitor subtle sample changes and perform failure mechanism analysis with the aid of offline material analysis using scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction. Furthermore, the system can be used for fatigue and high-low temperature impact tests.