Liya Zhu

Dr. Liya Zhu

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Journal of Advanced Research
Verified
Journal Article
Open access
MCMing Cheng
Ming Cheng
GZGuotao Zhu
Guotao Zhu
FZFeng Zhang
Feng Zhang
WTWen-Lai Tang
Wen-Lai Tang
JSJianping Shi
Jianping Shi
Liya ZhuLiya Zhu
Liya Zhu
In recent years, health monitoring systems (HMS) have aroused great interest due to their broad prospects in preventive medicine. As an important component of HMS, flexible force sensors (FFS) with high flexibility and stretch-ability can monitor vital health parameters and detect physical movements. In this review, the novel materials, the advanced additive manufacturing technologies, the selective sensing mechanisms and typical applications in both wearable and implantable HMS are discussed. We recognized that the next generation of the FFS will have higher sensitivity, wider linear range as well as better durability, self-power supplied and multifunctional integrated. In conclusion, the FFS will provide powerful socioeconomic benefits and improve people's quality of life in the future.

8 January 2023 in Journal of Advanced Research
Verified
Journal Article
Open access
LLLan Li
Lan Li
PWPeng Wang
Peng Wang
HLHuixin Liang
Huixin Liang
JJJing Jin
Jing Jin
YZYibo Zhang
Yibo Zhang
QJQing Jiang
Qing Jiang
The bone ingrowth depth in the porous scaffolds is greatly affected by the structural design, notably the pore size, pore geometry, and the pore distribution. To enhance the bone regeneration capability of scaffolds, the bionic design can be regarded as a potential solution. We proposed a Haversian system-like gradient structure based on the triply periodic minimal surface architectures with pore size varying from the edge to the center. And its effects in promoting bone regeneration were evaluated in the study. The gradient scaffold was designed using the triply periodic minimal surface architectures. The mechanical properties were analyzed by the finite element simulation and confirmed using the universal machine. The fluid characteristics were calculated by the computational fluid dynamics analysis. The bone regeneration process was simulated using a in silico computational model containing the main biological, physical, and chemical variation during the bone growth process. Finally, the in vitro and in vivo studies were carried out to verify the actual osteogenic effect. Compared to the uniform scaffold, the biomimetic gradient scaffold demonstrated better performance in stress conduction and reduced stress shielding effects. The fluid features were appropriate for cell migration and flow diffusion, and the permeability was in the same order of magnitude with the natural bone. The bone ingrowth simulation exhibited improved angiogenesis and bone regeneration. Higher expression of the osteogenesis-related genes, higher alkaline phosphatase activity, and increased mineralization could be observed on the gradient scaffold in the in vitro study. The 12-week in vivo study proved that the gradient scaffold had deeper bone inserting depth and a more stable bone-scaffold interface. The Haversian system-like gradient structure can effectively promote the bone regeneration. This structural design can be used as a new solution for the clinical application of prosthesis design.

1 April 2020 in Materials & Design
Verified
Journal Article
Open access
LLLan Li
Lan Li
KZKaijia Zhang
Kaijia Zhang
TWTiankuo Wang
Tiankuo Wang
PWPeng Wang
Peng Wang
BXBin Xue
Bin Xue
QJQing Jiang
Qing Jiang

18 March 2019 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
Liya ZhuLiya Zhu
Liya Zhu
LLLan Li
Lan Li
ZLZong'an Li
Zong'an Li
JSJian-Ping Shi
Jian-Ping Shi
WTWenlai Tang
Wenlai Tang
QJQing Jiang
Qing Jiang
Artificial meniscal implants can be used to replace a severely injured meniscus after meniscectomy and restore the normal functionality of a knee joint. The aim of this paper was to design porous meniscal implants and assess their biomechanical properties. Finite element simulations were conducted on eight different cases including intact healthy knees, knee joints with solid meniscal implants, and knee joints with meniscal implants with two types of triply periodic minimal surfaces. Compression stresses, shear stresses, and characteristics of stress concentrated areas were evaluated using an axial compressive load of 1150 N and an anterior load of 350 N. Compared to the solid meniscal implant, the proposed porous meniscal implant produced lower levels of compression and shear stresses on the cartilage, which facilitated the cartilage to retain a semilunar characteristic similar to the natural meniscus. Moreover, both compression and shear stresses on the artificial cartilage were found to be sensitive to the pore properties of the meniscal implant. The meniscal implants with primitive surfaces (porosity: 41%) showed a better performance in disseminating stresses within the knee joint. The present commercial meniscal implant has the problem of equivalent biomechanical properties compared to natural menisci. The main advantage of the proposed porous structure is that it can be used to prevent excessive compression and shear stresses on the articular cartilages. This structure has advantages both in terms of mechanics and printability, which can be beneficial for future clinical applications.

9 December 2021 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
GZGuotao Zhu
Guotao Zhu
HDHongtao Dai
Hongtao Dai
YYYao Yao
Yao Yao
WTWenlai Tang
Wenlai Tang
JSJianping Shi
Jianping Shi
Liya ZhuLiya Zhu
Liya Zhu

25 July 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
KZKaijia Zhang
Kaijia Zhang
LLLan Li
Lan Li
LYLongfei Yang
Longfei Yang
JSJianping Shi
Jianping Shi
Liya ZhuLiya Zhu
Liya Zhu
QJQing Jiang
Qing Jiang
Meniscal horns are important structures of meniscus, and longitudinal tears of these places could significantly change the load distribution among the knee joint. Few studies concerned the stress concentrated on bones, which may induce the osteonecrosis of subchondral bone. The goal of this study was to construct a finite element (FE) model with high fidelity of the knee joint and evaluate the biomechanical changes of load distribution of components after longitudinal tears of the horns of meniscus. Computed tomography and magnetic resonance images were used to develop the FE model, and two different kinds of simulations, the vertical and the anterior load, mimicking the static stance and slight flexion simulations, were applied after longitudinal tears of the horns of meniscus. Significantly elevated peak compressive and shear stress was observed on the menisci, cartilages, and subchondral bones, and enlarged meniscus extrusion was noticed. Between all the four types of longitudinal tears investigated in this study, longitudinal tears at the posterior horn of the medial meniscus were found to be the most significant. These findings showed that longitudinal tears of the meniscal horns lead to increased magnitude and changed distribution of stress and indicated the important role of posterior horn of medial meniscus. This may contribute to the mechanism between meniscal tears and spontaneous subchondral bone osteonecrosis.