Md Zakaria Habib Habib

Mr. Md Zakaria Habib Habib

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2016
Verified
Conference Paper
Closed access
MKMuhammad Talal Khan
Muhammad Talal Khan
MHMd Zakaria Habib Habib
Md Zakaria Habib Habib
EKElin Karlsson
Elin Karlsson
Davood BabazadehDavood Babazadeh
Davood Babazadeh
MFM Hassan Fidai
M Hassan Fidai
LNLars Nordstrom
Lars Nordstrom
Secondary frequency control plays a vital role in power systems and has therefore been the focus of much research. Recent focus is being targeted towards developing distributed solutions. This paper proposes a fast converging, distributed solution for secondary frequency control on the basis of the Alternating Direction Method of Multipliers (ADMM). For economic benefits the proposed solution integrates the use of rapid start (RS) units. Rapid start units are fast response and high ramp offiine units, which can provide the reserve power in case of need. The proposed control scheme is a distributed solution to combine secondary frequency control, economic dispatch and the RS start up process. Finally, the developed algorithm is tested for a power system model on a real-time co-simulation platform. The results show a fast converging algorithm that provides secondary frequency control compliant with ENTSO-E requirements, and the economical benefits of the inclusion of a rapid start unit.

20 August 2018 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
MHMd Zakaria Habib Habib
Md Zakaria Habib Habib
JWJianping Wang
Jianping Wang
YLYouyi Li
Youyi Li
NTNathaniel Taylor
Nathaniel Taylor
Line differential protection is popular for its good selectivity and simplicity as long as there is a dependable communication system between the two ends of the line. However, the sensitivity needs to be compromised when the traditional line differential scheme is applied for ultra‐high voltage (UHV)‐alternating current lines because of the large charging current. A study of the impact of the UHV transmission line characteristics on line differential protection and a proposed solution based on the compensation of the phase shift that exists between the sending and receiving end currents are presented.

24 March 2023 in Electricity
Verified
Journal Article
Open access
PDF file
MHMd Zakaria Habib Habib
Md Zakaria Habib Habib
NTNathaniel Taylor
Nathaniel Taylor
We propose a method for the fault passage indication of earth faults in resonant-earthed networks, based on phase current measurements alone. This is particularly relevant for electricity distribution systems at medium-voltage levels. The method is based on the relative magnitudes of the phasor changes in the phase currents due to the fault. It is tested for various network types and operation configurations by simulating the network in pscad and using the simulated currents as the input for an implementation of the method in matlab. In over-compensated networks, the method shows reliable detection of the fault passage, with good selectivity and sensitivity for both homogeneous and mixed (cable and overhead line) feeders. However, for the less common under-compensated systems, it has limitations that are described further in this study. The method has good potential for being cost effective since it requires only current measurements, from a single location, at a moderate sampling rate.

5 January 2023 in Energy Reports
Verified
Journal Article
Open access
MHMd Zakaria Habib Habib
Md Zakaria Habib Habib
SZSanja Duvnjak Zarković
Sanja Duvnjak Zarković
NTNathaniel Taylor
Nathaniel Taylor
PHPatrik Hilber
Patrik Hilber
ESEbrahim Shayesteh
Ebrahim Shayesteh
Fault location methods are crucial for reducing fault restoration time, and thus improving a network’s system average interruption duration index (SAIDI) and customer outage cost. Resonant-earthed systems pose problems for traditional fault location methods, leading to poor accuracy and a need for additional complexity. In this context, methods that detect fault direction (fault-passage indicators, FPI) at multiple points in the network may show advantages over a central distance-estimation method using fault locators (FL) of poor accuracy. This paper includes a comparative study of these two major fault location methods, comparing the reliability benefit from a varied number of FPIs or a central method. The optimal placement of the fault locating devices is found by formulating a mixed-integer linear programming (MILP) optimization approach that minimizes both outage and investment costs and assesses SAIDI. This approach has been tested on an example distribution system. However, to justify the universality of the algorithm, the RBTS reliability test system has also been analysed. The comparison of location methods and placement method of FPIs are useful for reliability centred planning of resonant-earthed distribution systems where fault location is to be used. Results show that a small number of FPIs that give accurate identification of direction may give more cost effective increase in reliability than a distance estimate by FL with typical levels of inaccuracy.