Patrik Hilber

Patrik Hilber

Auto-generated profile, based on publicly available information

Patrik Hilber

KTH Royal Institute of Technology, Teknikringen 31, Stockholm 100 44, Sweden

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ZLZhongtian Li
Zhongtian Li
PHPatrik Hilber
Patrik Hilber
Zhengmao LiZhengmao Li
Zhengmao Li
TLTor Laneryd
Tor Laneryd
SIStefan Ivanell
Stefan Ivanell
To cater to the advancement of electric and hydrogen-powered aircraft, airports are increasingly motivated to transition to green multi-energy airport microgrids (MEAM) for efficient operation and integration of stochastic renewable energy sources (RES). This paper presents a temporally coordinated (two-stage) stochastic programming (SP) model to minimize the energy supply cost of MEAMs while enabling efficient operations with electricity, green hydrogen and thermal energy. From the MEAM perspective, first, the multi-energy loads of MEAMs are considered flexible and modeled in details; second, the electricity-to-hydrogen-and-heat (E2HH) model is applied considering the influence of climatic conditions on the electrolyzers' efficiencies. With regard to the SP model, for one thing, the copula method is employed to capture correlations between climatic parameters related to RES generation and loads to enhance the accuracy and fidelity of the generated scenarios; for another, the Jensen wake model is applied to improve the estimation accuracy of available wind power in the generated scenarios. Furthermore, an adapted-penalty Progressive Hedging (PH) model is proposed to decompose the SP model, reducing the computational burden. Finally, case studies indicate that the proposed approach can effectively coordinate the operation of MEAM to balance system security and cost minimization.

1 May 2020 in Energy
Verified
Journal Article
Closed access
ZTZ. Tavassoli-Hojati
Z. Tavassoli-Hojati
SGS.F. Ghaderi
S.F. Ghaderi
SISeyed Hossein Iranmanesh
Seyed Hossein Iranmanesh
PHP. Hilber
P. Hilber
ESE. Shayesteh
E. Shayesteh

29 April 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JJJan Henning Jurgensen
Jan Henning Jurgensen
LNLars Nordstrom
Lars Nordstrom
PHPatrik Hilber
Patrik Hilber
The failure rate is essential in power system reliability assessment and thus far it has been commonly assumed as constant. This is a basic approach that delivers reasonable results. However, this approach neglects the heterogeneity in component populations which has a negative impact on the accuracy of the failure rate. This paper proposes a method based on risk functions, which describes the risk behaviour of condition measurements over time, to compute individual failure rates within populations. The method is applied to a population of 12 power transformers on transmission level. The computed individual failure rates depict the impact of maintenance and that power transformers with long operation times have a higher failure rate. Moreover, the paper presents a procedure based on the proposed approach to forecast failure rates. Finally, the individual failure rates are calculated over a specified prediction horizon and depicted with a 95% confidence interval.

1 April 2021 in Energy Reports
Verified
Journal Article
Open access
KQKaiqing Qiu
Kaiqing Qiu
WNWadih Naim
Wadih Naim
ESEbrahim Shayesteh
Ebrahim Shayesteh
PHPatrik Hilber
Patrik Hilber

1 November 2021 in Energy Reports
Verified
Journal Article
Open access
SŽSanja Duvnjak Žarković
Sanja Duvnjak Žarković
ESEbrahim Shayesteh
Ebrahim Shayesteh
PHPatrik Hilber
Patrik Hilber

2 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SASajjad Asefi
Sajjad Asefi
SASoheil Asefi
Soheil Asefi
HAHossein Afshari
Hossein Afshari
JKJako Kilter
Jako Kilter
ESEbrahim Shayesteh
Ebrahim Shayesteh
TLTommie Lindquist
Tommie Lindquist
High-voltage circuit breakers (HVCBs) are critical components in power systems to maintain reliable operation. Accurate condition monitoring of HVCBs is vital to reduce maintenance costs and consequently to enhance the grid reliability. However, achieving this with low-cost measurement devices, which often provide noisy signals, poses a significant challenge. In this article, a novel defect classification framework for HVCBs is proposed that uses the Savitzky–Golay filter to preprocess the most common condition monitoring signal, which is the trip/close coil current. This filter is well-known for denoising while preserving critical signal features. Following signal preprocessing, a robust defect detection and classification methodology is introduced, combining time-series similarity assessment techniques, such as Euclidean distance and dynamic time warping (DTW), with machine learning (ML) algorithms. Moreover, an experimental setup is designed to emulate the behavior of an HVCB’s coil mechanism. To further enhance the model transparency, Shapley additive explanations (SHAP) analysis is applied, providing interpretability into feature contributions toward model decisions. The obtained results validate the effectiveness of the proposed hybrid approach, demonstrating its potential to provide a cost-effective, accurate, and reliable solution for HVCB condition monitoring.