Xueling Bai

Xueling Bai


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2006 in Journal of Anatomy
Verified
Journal Article
Open access
PDF file
XBXueling Bai
Xueling Bai
LYLi Yu
Li Yu
QLQian Liu
Qian Liu
JZJie Zhang
Jie Zhang
ALAnan Li
Anan Li
HGHui Gong
Hui Gong
This paper reports the availability of a high‐resolution atlas of the adult rat. The atlas is composed of 9475 cryosectional images captured in 4600 × 2580 × 24‐bit TIFF format, constructed using serial cryosection‐milling techniques. Cryosection images were segmented, labelled and reconstructed into three‐dimensional (3D) computerized models. These images, 3D models, technical details, relevant software and further information are available at our website,http://vchibp.vicp.net/vch/mice/.

19 July 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PYPeng Yang
Peng Yang
QLQi Liu
Qi Liu
TLTianye Lin
Tianye Lin
AAAobulikasimu Aikebaier
Aobulikasimu Aikebaier
LJLuoyong Jiang
Luoyong Jiang
WSWei Sun
Wei Sun
Purpose: To investigate the early postoperative gait characteristics of patients who underwent periacetabular osteotomy (PAO) and predict the biomechanical performance of two commonly used PAO fixation methods: iliac screw (IS) and transverse screw (TS).Methods: A total of 12 patients with unilateral developmental dysplasia of the hip (DDH) (mean age 27.81 ± 4.64 years, 42% male) that were scheduled to undergo PAO surgery were included in this study. Their preoperative CT images and pre- and postoperative gait data were used to create subject-specific musculoskeletal models and complete the inverse dynamics analysis (IDA). Two patients with typical gait characteristics were selected using clustering analysis, and their IDA data were incorporated into finite element (FE) models of IS and TS fixations. Failure simulation was performed by applying iterative steps with increasing gait load to predict yield load. Stress results and yield loads were calculated for each FE model at different phases of the gait cycle.Results: Postoperative gait showed improvement compared to preoperative gait but remained inferior to that of healthy individuals. Postoperative gait was characterized by a lower hip range of motion, lower peri-ilium muscle forces, particularly in the abductors, and a sharper initial peak and flatter second peak of hip joint reaction force (HRF). Finite element analysis (FEA) showed a trend of increasing stress during the second–fourth phases of the gait cycle, with lower stress levels in other phases. At high-stress gait phases, the mean stress of maximum p¯100 differed significantly between IS and TS (p < 0.05) and between coupled and uncoupled muscle forces (p < 0.05). Failure analysis predicted a slightly larger yield load for TS configurations (6.21*BW) than that for IS (6.16*BW), but both were well above the gait load. Coupled and uncoupled groups showed similar results, but uncoupled groups had lower yield loads (5.9*BW).Conclusion: PAO early postoperative gait shows a normalized trend, but abnormalities persist. IS and TS are both capable of resisting mechanical strain failure, with no significant mechanical advantage found for transverse screw fixation during PAO early postoperative gait. Additionally, it is important to note that the TS may have a higher risk of cyclic fatigue failure due to the localized greater stress concentration. Furthermore, the most medial screw is crucial for pelvic stability.

17 June 2024 in Bone & Joint Research
Verified
Journal Article
Open access
PDF file
PYPeng Yang
Peng Yang
WHWei He
Wei He
WYWeiming Yang
Weiming Yang
LJLuoyong Jiang
Luoyong Jiang
TLTianye Lin
Tianye Lin
WSWei Sun
Wei Sun
Aims: In this study, we aimed to visualize the spatial distribution characteristics of femoral head necrosis using a novel measurement method.Methods: We retrospectively collected CT imaging data of 108 hips with non-traumatic osteonecrosis of the femoral head from 76 consecutive patients (mean age 34.3 years (SD 8.1), 56.58% male (n = 43)) in two clinical centres. The femoral head was divided into 288 standard units (based on the orientation of units within the femoral head, designated as N[Superior], S[Inferior], E[Anterior], and W[Posterior]) using a new measurement system called the longitude and latitude division system (LLDS). A computer-aided design (CAD) measurement tool was also developed to visualize the measurement of the spatial location of necrotic lesions in CT images. Two orthopaedic surgeons independently performed measurements, and the results were used to draw 2D and 3D heat maps of spatial distribution of necrotic lesions in the femoral head, and for statistical analysis.Results: The results showed that the LLDS has high inter-rater reliability. As illustrated by the heat map, the distribution of Japanese Investigation Committee (JIC) classification type C necrotic lesions exhibited clustering characteristics, with the lesions being concentrated in the northern and eastern regions, forming a hot zone (90% probability) centred on the N4-N6E2, N3-N6E units of outer ring blocks. Statistical results showed that the distribution difference between type C2 and type C1 was most significant in the E1 and E2 units and, combined with the heat map, indicated that the spatial distribution differences at N3-N6E1 and N1-N3E2 units are crucial in understanding type C1 and C2 necrotic lesions.Conclusion: The LLDS can be used to accurately measure the spatial location of necrotic lesions and display their distribution characteristics.Cite this article: Bone Joint Res 2024;13(6):294–305.

1 January 2014
Verified
Book Chapter
Closed access
PDF file
XYXin Ye
Xin Ye
LZLinan Zhang
Linan Zhang
ZXZaobing Xu
Zaobing Xu
ZHZengtao Hou
Zengtao Hou
XBXueling Bai
Xueling Bai
SPShang Peng
Shang Peng