Li Yu

Li Yu

Auto-generated profile, based on publicly available information

Li Yu

National Gravitation Laboratory, the MOE Key Laboratory of Fundamental Physical Quantities Measurement, and the School of Physics, Huazhong University of Science and Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2006 in Journal of Anatomy
Verified
Journal Article
Open access
PDF file
XBXueling Bai
Xueling Bai
LYLi Yu
Li Yu
QLQian Liu
Qian Liu
JZJie Zhang
Jie Zhang
ALAnan Li
Anan Li
HGHui Gong
Hui Gong
This paper reports the availability of a high‐resolution atlas of the adult rat. The atlas is composed of 9475 cryosectional images captured in 4600 × 2580 × 24‐bit TIFF format, constructed using serial cryosection‐milling techniques. Cryosection images were segmented, labelled and reconstructed into three‐dimensional (3D) computerized models. These images, 3D models, technical details, relevant software and further information are available at our website,http://vchibp.vicp.net/vch/mice/.

20 July 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MYMingbiao Yu
Mingbiao Yu
TCTijing Cai
Tijing Cai
LTLiangcheng Tu
Liangcheng Tu
CHChenyuan Hu
Chenyuan Hu
LYLi Yu
Li Yu
Mounting requirements of a rotating accelerometer gravity gradiometer (RAGG) beyond the art of manufacture, the RAGG is susceptible to the motion of itself. Motion error is a main source of error in airborne gravity gradiometry data. This study presented a post error compensation method, which consists of post motion error compensation and post self-gradient compensation. The motion error and self-gradients are compensated before that the combination output of the four accelerometers is quadrature amplitude demodulated. The motion error compensation is based on the RAGG analytical model; motion response of the RAGG (namely motion error) is related well to the motion of the RAGG, independent of the gravitational gradient response; recording the motion status of the RAGG, with least squares regression method and the RAGG analytical model, the motion response of the RAGG are separated and removed. RAGG numerical simulation experiments results show that the post motion error compensation method is feasible, and its limit accuracy could reach 0.5 E/√ Hz.

9 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JPJianyuan Pi
Jianyuan Pi
XYXiaobing Yu
Xiaobing Yu
PCPeng Chen
Peng Chen
MYMingbiao Yu
Mingbiao Yu
LYLi Yu
Li Yu
LTLiangcheng Tu
Liangcheng Tu
Rotating Accelerometer Gravity Gradientmeter (RAGG) is the only gravity gradient measuring device in the world to achieve commercial applications. When the parameter consistency among multiple accelerometers of the RAGG is not sufficient, its combined output cannot effectively suppress common-mode noise in the environment. A method for suppressing RAGG’s linear and angular motion noise is presented in this paper by projecting the parameters, including scale factor, misalignment angle, second-order terms and cross-coupling terms, onto the cartesian coordinate system of the turntable plane. Proposing the algorithm implementation scheme of three effective scale factor solver loops, and for further canceling the motion residual error, high precision gyroscope compensation loops is introduced. The added error compensation loop obtains the angular acceleration by differencing the angular velocity measured by the gyroscope, which in turn adjusts the loop parameters. Experimental results show that with the proposed method, the noise suppression of linear motion common-mode acceleration reaches 6.5 orders of magnitude, that is, the noise level 2.7 × 10 -8 g/ √ Hz of the accelerometer at the rotation frequency, and the angular motion common-mode acceleration noise is suppressed by 6 orders of magnitude, and the noise level 6.8×10 -8 g/ √ Hz of the accelerometer at the swing frequency is also obtained.

30 November 2021 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
MYMingbiao Yu
Mingbiao Yu
TCTijing Cai
Tijing Cai
LTLiangcheng Tu
Liangcheng Tu
CHChenyuan Hu
Chenyuan Hu
JFJi Fan
Ji Fan
LYLi Yu
Li Yu
Limited by manufacturing technology, in moving-base gravity gradiometry, accelerometer mounting errors and mismatch cause a rotating accelerometer gravity gradiometer (RAGG) to be susceptible to its own motion. In this study, we comprehensively consider accelerometer mounting errors, accelerometer linear scale factors imbalances, accelerometer second-order error coefficients, RAGG internal movement, and construct three RAGG models—namely, a numerical model, an 54 parameters analytical model, and a 25 parameters simplified analytical model. Moreover, by setting the gravitational gradient excitation of RAGG to zero, the RAGG motion error model is derived. The analytical model and motion error model are used to interpret the error propagation mechanism and develop RAGG technical solutions, such as motion error compensation, fault diagnosis, etc. The numerical model is used to facilitate the verification of the RAGG analytical model and RAGG technical solutions. We performed multifrequency gravitational gradient simulation experiment and dynamic sweep frequency experiments to verify the three RAGG models, and evaluate the dynamic noise floor of the analytical models. In dynamic experiments, standard deviation of RAGG vertical specific force grows from 10 to 40 mg (1 g = 9.8 m/s2); that of the lateral specific force grows from 5 to 20 mg; the noise density of the analytical model remains stable within 2.5 E/✓ Hz, and that of the simplified analytical model is in the range of 2.64–41.27 E/✓Hz.

16 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYu Liang
Yu Liang
ZPZhe Pei
Zhe Pei
LYLi Yu
Li Yu
XGXukai Guo
Xukai Guo
XYXiaobing Yu
Xiaobing Yu
HUAFENG LIUHUAFENG LIU
HUAFENG LIU
The high precision turntable plays a crucial role in the measurement of inertial sensors, aerospace applications and other fields, and thus it is imperative to evaluate and measure its angular acceleration error accurately, particularly in a rotating accelerometer gravity gradiometer (RAGG). To address the issues of delay and noise amplification caused by differentiation in traditional measurement methods like grating and gyroscope, this article proposes a novel measurement method based on the combination of high precision accelerometers. Firstly, a numerical model is established through principle derivation followed by obtaining an analytical model through error analysis. Secondly, simulation verification and preliminary experimental measurements are conducted. Finally, a comparison experiment with commercial gyroscope is designed to further validate the proposed method. The experimental results demonstrate that compared to the gyroscope, the proposed method exhibits lower a static noise level: 1.601×10 -7 (rad/s 2 )/Hz 1/2 at 0.2-5 Hz which surpasses the performance of high precision fiber optic gyroscopes by more than one order of magnitude. Therefore, this innovative multi-accelerometer-based method can be considered as a favorable option for measuring angular acceleration with ultra-low noise levels on high precision turntables.

22 February 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
XYXiaobing Yu
Xiaobing Yu
TJTao Jiang
Tao Jiang
LYLi Yu
Li Yu
JPJianyuan Pi
Jianyuan Pi
XGXukai Guo
Xukai Guo
HLHuafeng Liu
Huafeng Liu
The rotating accelerometer gravity gradiometer (RAGG) is regarded as a significant tool in geophysics applications such as resource exploration and gravity-assisted navigation research. Here we develop a prototype of the horizontal tensor RAGG and build a dedicated calibration platform for evaluating its performance. The error of calibration is theoretically computed and experimentally verified. The errors considered include higher-order terms of the gravity gradient error, positioning error, demodulation phase error, as well as the dimensions and density error of the gravitational mass. It has witnessed a high-accuracy gravity gradient calibration platform based on a motorized translation stage, with error values of 0.49 E (1 E = 10−9 s2) in channel Γ sin and 0.24 E in channel Γ cos . At an averaging time of 32 s, the RAGG demonstrates optimal stability, featuring a minimum Allan deviation value of 6.6 E in channel Γ sin and 5.5 E in channel Γ cos . And the RAGG has achieved a measurement noise floor of about 40 E/√Hz @ 0.001–0.1 Hz in both channels. For simulating engineering applications, the experimental results demonstrate a standard deviation error of only 3.2 E by employing a gravity gradient excitation step signal of 10 E. It shows that this RAGG has the potential for a wide range of applications.