Zhigang Wu

Prof. Dr. Zhigang Wu

School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Rd, Wuhan 430074, China
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2004 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
Nam-Trung NguyenNam-Trung Nguyen
Nam-Trung Nguyen
ZWZhigang Wu
Zhigang Wu

11 May 2016 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
SJSeunghee Jeong
Seunghee Jeong
SZShuo Zhang
Shuo Zhang
KHKlas Hjort
Klas Hjort
JHJöns Hilborn
Jöns Hilborn
ZWZhigang Wu
Zhigang Wu

26 April 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SCShi Cheng
Shi Cheng
ZWZhigang Wu
Zhigang Wu
Microfluidics, a field that has been well-established for several decades, has seen extensive applications in the areas of biology, chemistry, and medicine. However, it might be very hard to imagine how such soft microfluidic devices would be used in other areas, such as electronics, in which stiff, solid metals, insulators, and semiconductors have previously dominated. Very recently, things have radically changed. Taking advantage of native properties of microfluidics, advances in microfluidics-based electronics have shown great potential in numerous new appealing applications, e.g. bio-inspired devices, body-worn healthcare and medical sensing systems, and ergonomic units, in which conventional rigid, bulky electronics are facing insurmountable obstacles to fulfil the demand on comfortable user experience. Not only would the birth of microfluidic electronics contribute to both the microfluidics and electronics fields, but it may also shape the future of our daily life. Nevertheless, microfluidic electronics are still at a very early stage, and significant efforts in research and development are needed to advance this emerging field. The intention of this article is to review recent research outcomes in the field of microfluidic electronics, and address current technical challenges and issues. The outlook of future development in microfluidic electronic devices and systems, as well as new fabrication techniques, is also discussed. Moreover, the authors would like to inspire both the microfluidics and electronics communities to further exploit this newly-established field.

13 February 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ZWZhigang Wu
Zhigang Wu
BWBen Willing
Ben Willing
JBJoakim Bjerketorp
Joakim Bjerketorp
JJJanet K. Jansson
Janet K. Jansson
KHKlas Hjort
Klas Hjort
We developed a new approach to separate bacteria from human blood cells based on soft inertial force induced migration with flow defined curved and focused sample flow inside a microfluidic device. This approach relies on a combination of an asymmetrical sheath flow and proper channel geometry to generate a soft inertial force on the sample fluid in the curved and focused sample flow segment to deflect larger particles away while the smaller ones are kept on or near the original flow streamline. The curved and focused sample flow and inertial effect were visualized and verified using a fluorescent dye primed in the device. First the particle behaviour was studied in detail using 9.9 and 1.0 µm particles with a polymer-based prototype. The prototype device is compact with an active size of 3 mm2. The soft inertial effect and deflection distance were proportional to the fluid Reynolds number (Re) and particle Reynolds number (Rep), respectively. We successfully demonstrated separation of bacteria (Escherichia coli) from human red blood cells at high cell concentrations (above 108/mL), using a sample flow rate of up to 18 µL/min. This resulted in at least a 300-fold enrichment of bacteria at a wide range of flow rates with a controlled flow spreading. The separated cells were proven to be viable. Proteins from fractions before and after cell separation were analyzed by gel electrophoresis and staining to verify the removal of red blood cell proteins from the bacterial cell fraction. This novel microfluidic process is robust, reproducible, simple to perform, and has a high throughput compared to other cell sorting systems. Microfluidic systems based on these principles could easily be manufactured for clinical laboratory and biomedical applications.

6 April 2009 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SCShi Cheng
Shi Cheng
ARAnders Rydberg
Anders Rydberg
Klas HjortKlas Hjort
Klas Hjort
ZWZhigang Wu
Zhigang Wu
We present a 2.4 GHz unbalanced loop antenna that can be stretched along multiple dimensions simultaneously. It was realized by incorporating room temperature liquid metal alloy into microstructured channels in an elastic material. The demonstrated prototype exhibits a stretchability of up to 40% along two orthogonal orientations as well as foldability and twistability. Port impedance and radiation characteristics of the nonstretched and stretched antenna were studied numerically and experimentally. Measured results indicate a radiation efficiency of more than 80%.

17 September 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SJSeunghee Jeong
Seunghee Jeong
AHAnton Hagman
Anton Hagman
KHKlas Hjort
Klas Hjort
MJMagnus Jobs
Magnus Jobs
JSJohan Sundqvist
Johan Sundqvist
ZWZhigang Wu
Zhigang Wu
Recently, microfluidic stretchable electronics has attracted great interest from academia since conductive liquids allow for larger cross-sections when stretched and hence low resistance at longer lengths. However, as a serial process it has suffered from low throughput, and a parallel processing technology is needed for more complex systems and production at low costs. In this work, we demonstrate such a technology to implement microfluidic electronics by stencil printing of a liquid alloy onto a semi-cured polydimethylsiloxane (PDMS) substrate, assembly of rigid active components, encapsulation by pouring uncured PDMS on-top and subsequent curing. The printing showed resolution of 200 μm and linear resistance increase of the liquid conductors when elongated up to 60%. No significant change of resistance was shown for a circuit with one LED after 1000 times of cycling between a 0% and an elongation of 60% every 2 s. A radio frequency identity (RFID) tag was demonstrated using the developed technology, showing that good performance could be maintained well into the radio frequency (RF) range.