Kristi Lyn Jones

Dr. Kristi Lyn Jones


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2022 in Animals
Verified
Journal Article
Open access
PDF file
KJKristi Lyn Jones
Kristi Lyn Jones
AMAmeer A Megahed
Ameer A Megahed
BDBrittany Diehl
Brittany Diehl
ACAnn M Chan
Ann M Chan
OHOscar Hernández
Oscar Hernández
JBJoão H.J. Bittar
João H.J. Bittar
Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. Our objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay across the reportable range in ovine serum. This validation of analytical performance included determining (1) linearity, (2) precision through within-run, and between-run coefficient of variation (CV) calculations, (3) accuracy through bias calculations for spiking-recovery bias and interlaboratory (range and average based) bias for two laboratories across the reportable range (0.2–40 ng/mL). The average within-run and between-run precision (CV%) across the reportable range of the IMMULITE® 2000 XPi P4 immunoassay for serum P4 concentration were both <5%, ranging between 2–8%. The average Observed Total Analytic Error (TEo) reported here for serum P4 concentration across the reportable range was ~30%, ranging from 14.8–59.4%, regardless of the considered bias. Based on these data we conclude that the automated IMMULITE® 2000 XPi P4 immunoassay provides a precise, accurate, reliable, and safe method for measuring P4 concentration ovine serum.

10 April 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
KJKristi Lyn Jones
Kristi Lyn Jones
FCFederico Cunha
Federico Cunha
SCSegundo Casaro
Segundo Casaro
KGKlibs Galvão
Klibs Galvão
Bacteremia, specifically if progressed to sepsis, poses a time-sensitive threat to human and animal health. Escherichia coli is a main causative agent of sepsis in humans. The objective was to evaluate a propidium monoazide (PMA)-based viability PCR (vPCR) protocol to detect and quantify live E. coli from whole blood. We optimized the protocol by adding a eukaryotic-specific lysis step prior to PMA exposure, then used spiking experiments to determine the lower limit of detection (LOD) and linear range of quantification. We also compared the vPCR quantification method to standard colony count of spiked inoculum. Lastly, we calculated percent viability in spiked samples containing 50% live cells or 0% live cells. The LOD was 102 CFU/mL for samples containing live cells only and samples with mixed live and heat-killed cells. The linear range of quantification was 102 CFU/mL to 108 CFU/mL (R2 of 0.997) in samples containing only live cells and 103 CFU/mL to 108 CFU/mL (R2 of 0.998) in samples containing live plus heat-killed cells. A Bland–Altman analysis showed that vPCR quantification overestimates compared to standard plate count of the spiked inoculum, with an average bias of 1.85 Log10 CFU/mL across the linear range when only live cells were present in the sample and 1.98 Log10 CFU/mL when live plus heat-killed cells were present. Lastly, percent viability calculations showed an average 89.5% viable cells for samples containing 50% live cells and an average 19.3% for samples containing 0% live cells. In summary, this optimized protocol can detect and quantify viable E. coli in blood in the presence of heat-killed cells. Additionally, the data presented here provide the groundwork for further development of vPCR to detect and quantify live bacteria in blood in clinical settings.