Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. Our objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay across the reportable range in ovine serum. This validation of analytical performance included determining (1) linearity, (2) precision through within-run, and between-run coefficient of variation (CV) calculations, (3) accuracy through bias calculations for spiking-recovery bias and interlaboratory (range and average based) bias for two laboratories across the reportable range (0.2–40 ng/mL). The average within-run and between-run precision (CV%) across the reportable range of the IMMULITE® 2000 XPi P4 immunoassay for serum P4 concentration were both <5%, ranging between 2–8%. The average Observed Total Analytic Error (TEo) reported here for serum P4 concentration across the reportable range was ~30%, ranging from 14.8–59.4%, regardless of the considered bias. Based on these data we conclude that the automated IMMULITE® 2000 XPi P4 immunoassay provides a precise, accurate, reliable, and safe method for measuring P4 concentration ovine serum.
1 October 2022 in Journal of the American Veterinary Medical Association
Gastrointestinal parasites are a major health and economic concern in small ruminants. The classic microscopic approach using the manual McMaster method serves to quantitatively count parasite eggs, which are labor-intensive and prone to variation. Artificial intelligence-based systems (Parasight®, powered by Fecalsight AI™) could provide quicker and more objective alternatives; therefore, independent validation is necessary before clinical implementation. The objective of this study was to evaluate the agreement, classification consistency, and diagnostic performance of Parasight® relative to the manual McMaster method, with a focus on its suitability as a screening and decision-support tool. Fecal samples from 44 Kiko goats over 3 sampling times were analyzed using both methods, with manual counts performed independently by 2 observers. Agreement between methods was assessed using Lin’s concordance correlation coefficient, Bland–Altman analysis, and Cohen’s Kappa for categorical classification. Diagnostic performance for identifying animals exceeding the clinical treatment threshold (>1000 eggs per gram) was evaluated using receiver operating characteristic (ROC) analysis, and regression modeling was used to characterize associations between methods. Manual observers showed high reliability, confirming the suitability of the McMaster method as a reference. Compared with manual counts, Parasight® consistently underestimated egg counts, resulting in poor-to-moderate absolute agreement; however, it reliably ranked animals by parasite burden and showed excellent discrimination for identifying animals above the treatment threshold (AUC = 0.90–0.96). Regression analyses further demonstrated linear or curvilinear associations depending on egg counts. Overall, the Parasight® device reliably captured relative parasite burden but required a lower operational threshold to match manual treatment decisions.