This in vitro study evaluated the accuracy of guided endodontics for the removal of intraradicular fiberglass posts from posterior mandibular teeth and the influence of the operator’s experience in this procedure. Forty root-filled mandibular first molars with an intraradicular fiberglass post were mounted onto 20 mandibular models. Guides for access were made following surface scanning and cone-beam computed tomography (CBCT) using CoDiagnostix software. The models were randomly divided between two operators (n = 20). One was an inexperienced dental surgeon (IN), and the other was a dentist experienced in the guided technique (EX). A postoperative CBCT scan was superimposed on the initial planning, and the means were calculated for the angle and for 3D deviation. The 95% confidence interval (CI) was calculated, and differences between groups were assessed by a t-test. The mean deviation angle was 2.54° (0–5.85°) for IN and 1.55° (0–2.85°) for EX. The mean 3D deviation was 0.44 mm (0.14–0.73 mm) for IN and 0.33 mm (0.11–0.76 mm) for EX. The means of the angle and 3D deviation were significantly different (p = 0.008 and p = 0.049). Guided endodontics was influenced by the operator and allowed access for removing intraradicular fiberglass posts with minimal deviation and greater accuracy for an experienced operator compared with an inexperienced one.
Objective This study compared the shaping ability of the Hyflex CM and XP-endo Shaper rotary file systems in curved mesial canals of mandibular molars using micro-computed tomography. Material and Methods Seventeen mesial roots of extracted first mandibular molars with two independent mesial canals were scanned before and after root canal preparation with the tested rotatory file systems. Each mesial canal from the same specimen was prepared with one of the two systems. The parameters analyzed were canal centering (transportation) for the cervical, middle, and apical segments, as well as for the entire canal (0–10 mm from the apex); and canal volume increase, canal surface area increase, and unprepared canal walls for two segments, 0 to 4 mm and 0 to 10 mm from the apex. Results There was no significant difference between both systems regarding canal centering (transportation), volume increase, and unprepared canal walls for the 0 to 10 mm segment (p> 0.05); however, a significant difference was observed for the 0 to 4 mm segment (p <0.01), where the Hyflex CM left 28.46% of unprepared walls and XP-endo Shaper left 13.26%. Conclusions The shaping ability of the two tested rotatory file systems in mesial roots of first mandibular molars was similar for all parameters in all the segments evaluated, except for the 0 to 4 mm segment, where XP-endo Shaper left a smaller area of unprepared canal walls than Hyflex CM.
This study assessed the influence of apical preparation size and final irrigation protocol on the debridement of the apical third of oval root canals of mandibular molars. Seventy-seven distal roots were divided into 7 groups (n = 11): Control: without instrumentation or irrigation; Group 30CI: ProTaper Next (up to size 30; PTN) + conventional irrigation (CI); Group 30UAI: PTN + ultrasonically activated irrigation (UAI); Group 30XPF: PTN + XP-endo Finisher (XPF); Group 40CI: PTN + ProDesign Logic (up to size 40; PDL) + CI; Group 40UAI: PTN + PDL + UAI; and Group 40XPF: PTN + PDL + XPF. The total volume of irrigating solutions used per root canal in all the experimental groups was 33 mL of 2.5% sodium hypochlorite (NaOCl) and 6 mL of 17% ethylenediaminetetraacetic acid (EDTA). After specimen processing and histological analysis under a digital microscope (100x), the percentages of untouched canal walls (UCW) and remaining debris (RD) were assessed using Image J software. A descriptive and exploratory analysis was conducted, indicating that the data failed to meet the assumptions of an analysis of variance. Therefore, generalized linear models were used to assess the effects of the different instrumentation and irrigation protocols, as well as the interaction among them, on the percentage of UCW and RD. No significant difference was found among the irrigation protocols regarding the percentage of UCW, irrespective of apical preparation size (p>0.05). However, UCW and RD were significantly lower in groups 40CI, 40UAI and 40XPF than in groups 30CI, 30UAI and 30XPF (p<0.05). The percentage of RD was significantly lower in the UAI and XPF groups than in the CI groups, irrespective of apical preparation size (p<0.05). The difference between preparation sizes 30 and 40, with respect to RD, was higher when CI was used (p<0.05). In conclusion, instrumentation up to apical preparation size 40 resulted in lower percentages of UCW and RD than up to apical preparation size 30. Use of UAI or XPF resulted in lower percentages of RD than CI.