Alexandre Sigrist De Martin

Alexandre Sigrist De Martin

Auto-generated profile, based on publicly available information

Alexandre Sigrist De Martin

São Leopoldo Mandic University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
CSCláudia Fernandes de Magalhães Silveira
Cláudia Fernandes de Magalhães Silveira
RCRodrigo Sanches Cunha
Rodrigo Sanches Cunha
CFCarlos Eduardo Fontana
Carlos Eduardo Fontana
AMAlexandre Sigrist de Martin
Alexandre Sigrist de Martin
Brenda Paula GomesBrenda Paula Gomes
Brenda Paula Gomes
CBCarlos Eduardo da Silveira Bueno
Carlos Eduardo da Silveira Bueno
Objectives: The purpose of this study was to assess the in vitro antibacterial activity of four formulations of calcium hydroxide [Ca(OH)2] pastes against Enterococcus faecalis, Staphylococcus aureus, Pseudomonas aeruginosa and Streptococcus mutans. Methods: A broth dilution test was performed, and the lengths of time for different pastes to kill the microbial cells were recorded and statistically analyzed. The following medications were assessed: Group I – Ca(OH)2 + 2.0% chlorhexidine (CHX) gel; Group II – Ca(OH)2 + camphorated paramonochlorophenol (CMCP) and propylene glycol; Group III – Ca(OH)2 + propylene glycol; Group IV – Ca(OH)2 + saline. Results: The results showed that E. faecalis was the most resistant microorganism. Groups II and III eliminated all the microbial cells in 15 seconds. Group I took 45 seconds to eliminate E. faecalis. Conclusions: Under the conditions of this study, it was concluded that all the intracanal medications tested showed antibacterial activity. However, the association of Ca(OH)2 and PMCC or Ca(OH)2 and propylene glycol showed a better performance, since Groups II and III took a shorter length of time than the other groups to eliminate S. aureus and E. faecalis. (Eur J Dent 2011;5:1-7)

27 December 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FRFernando Antonio Siano dos Reis
Fernando Antonio Siano dos Reis
Amjad Abu HasnaAmjad Abu Hasna
Amjad Abu Hasna
GRGustavo Ragozzini
Gustavo Ragozzini
FMFelipe Bernardo de Moura
Felipe Bernardo de Moura
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
CBCarlos Eduardo Silveira Bueno
Carlos Eduardo Silveira Bueno
This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey’s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.

1 January 2024 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
GRGustavo Ragozzini
Gustavo Ragozzini
Amjad Abu HasnaAmjad Abu Hasna
Amjad Abu Hasna
FRFernando Antonio Siano dos Reis
Fernando Antonio Siano dos Reis
FMFelipe Bernardo de Moura
Felipe Bernardo de Moura
TCTiago Moreira Bastos Campos
Tiago Moreira Bastos Campos
AMAlexandre Sigrist de Martin
Alexandre Sigrist de Martin
This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments’ fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica‐like instruments (TF4‐Gold, Roll‐Wave‐Gold, W‐File, and Micro‐Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi‐square, one‐way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4‐Gold, and Roll‐Wave‐Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.

1 January 2021 in Restorative Dentistry & Endodontics
Verified
Journal Article
Open access
PDF file
LRLiliana Machado Ruivo
Liliana Machado Ruivo
MRMarcos de Azevedo Rios
Marcos de Azevedo Rios
AVAlexandre Mascarenhas Villela
Alexandre Mascarenhas Villela
AMAlexandre Sigrist de Martin
Alexandre Sigrist de Martin
AKAugusto Shoji Kato
Augusto Shoji Kato
CBCarlos Eduardo da Silveira Bueno
Carlos Eduardo da Silveira Bueno
Ruivo LM, et al. Restor Dent Endod. 2021 Sep;46:e49. https://doi.org/10.5395/rde.2021.46.e49

11 October 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
WDWania Christina Figueiredo Dantas
Wania Christina Figueiredo Dantas
MMMarilia Fagury Videira Marceliano-Alves
Marilia Fagury Videira Marceliano-Alves
EMEduardo Fagury Videira Marceliano
Eduardo Fagury Videira Marceliano
EMEduardo Fernandes Marques
Eduardo Fernandes Marques
TCThais Machado de Carvalho Coutinho
Thais Machado de Carvalho Coutinho
CBCarlos Eduardo da Silveira Bueno
Carlos Eduardo da Silveira Bueno
Objective This study compared the shaping ability of the Hyflex CM and XP-endo Shaper rotary file systems in curved mesial canals of mandibular molars using micro-computed tomography. Material and Methods Seventeen mesial roots of extracted first mandibular molars with two independent mesial canals were scanned before and after root canal preparation with the tested rotatory file systems. Each mesial canal from the same specimen was prepared with one of the two systems. The parameters analyzed were canal centering (transportation) for the cervical, middle, and apical segments, as well as for the entire canal (0–10 mm from the apex); and canal volume increase, canal surface area increase, and unprepared canal walls for two segments, 0 to 4 mm and 0 to 10 mm from the apex. Results There was no significant difference between both systems regarding canal centering (transportation), volume increase, and unprepared canal walls for the 0 to 10 mm segment (p> 0.05); however, a significant difference was observed for the 0 to 4 mm segment (p <0.01), where the Hyflex CM left 28.46% of unprepared walls and XP-endo Shaper left 13.26%. Conclusions The shaping ability of the two tested rotatory file systems in mesial roots of first mandibular molars was similar for all parameters in all the segments evaluated, except for the 0 to 4 mm segment, where XP-endo Shaper left a smaller area of unprepared canal walls than Hyflex CM.

30 April 2024 in Acta Odontológica Latinoamericana
Verified
Journal Article
Open access
TMThamara C Maluf
Thamara C Maluf
CBCarlos E Bueno
Carlos E Bueno
RPRina Andrea Pelegrine
Rina Andrea Pelegrine
CFCarlos Eduardo Fontana
Carlos Eduardo Fontana
DRDaniel Gp Rocha
Daniel Gp Rocha
AMAlexandre S de Martin
Alexandre S de Martin
Knowledge of root canal internal anatomy and its variations is important for proper endodontic treatment. It is therefore necessary to investigate morphological aspects among different dental groups in the same patient to define the best protocol for the case. Aim: To evaluate the morphology and symmetry of homologous incisors, premolars and mandibular molars using cone beam computed tomography (CBCT). Materials and Method: Descriptive statistical analysis was performed for the frequency of categorical variables, and a chi-square test or Fisher’s exact test was used to test whether gender and side were associated with number of roots, number of canals, and Vertucci’s classification. Forty-five CBCT scans were evaluated, and 444 mandibular teeth were analyzed. The number of roots, number of canals, classification of the canals in each root according to Vertucci and presence of a symmetrical relationship between pairs of posterior teeth were analyzed. Results: The resuls showed that 74% of mandibular central incisors had type I root canal, 26% of mandibular lateral incisors had type I and, with a significant difference in the number of canals between males and females (p < 0.05). In mandibular first premolars, 70.5% had type I; and in mandibular second premolars, 98.5% had type I. Mandibular first molars had two roots in 98% of the cases. Second mandibular molars had two roots in 92.5% of the cases, one root in 6%, and three roots in 1.5%. Symmetry between central incisors was higher in females than in males. Conclusion: Teeth of the same group can have different morphologies in the same patient.