The demand for new devices that enable the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) at a relatively low cost and that are fast and feasible to be used as point-of-care is required overtime on a large scale. In this sense, the use of sustainable materials, for example, the bio-based poly (ethylene terephthalate) (Bio-PET) can be an alternative to current standard diagnostics. In this work, we present a flexible disposable printed electrode based on a platinum thin film on Bio-PET as a substrate for the development of a sensor and immunosensor for the monitoring of COVID-19 biomarkers, by the detection of L-cysteine and the SARS-CoV-2 spike protein, respectively. The electrode was applied in conjunction with 3D printing technology to generate a portable and easy-to-analyze device with a low sample volume. For the L-cysteine determination, chronoamperometry was used, which achieved two linear dynamic ranges (LDR) of 3.98−39.0 μmol L−1 and 39.0−145 μmol L−1, and a limit of detection (LOD) of 0.70 μmol L−1. The detection of the SARS-CoV-2 spike protein was achieved by both square wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) by a label-free immunosensor, using potassium ferro-ferricyanide solution as the electrochemical probe. An LDR of 0.70−7.0 and 1.0−30 pmol L−1, with an LOD of 0.70 and 1.0 pmol L−1 were obtained by SWV and EIS, respectively. As a proof of concept, the immunosensor was successfully applied for the detection of the SARS-CoV-2 spike protein in enriched synthetic saliva samples, which demonstrates the potential of using the proposed sensor as an alternative platform for the diagnosis of COVID-19 in the future.
This work reports the fabrication of a novel electrochemical sensor leveraging reduced graphene oxide (rGO) modified with samarium oxide (Sm2O3) nanoparticles to enhance dopamine (DA) detection. The primary goal was to create a sensitive and selective platform capable of distinguishing DA in complex biological environments. The sensor was synthesized using a hydrothermal method to form rGO/Sm2O3 composites, followed by characterization employing scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), and high-resolution TEM (HR-TEM) and Raman spectroscopy to confirm morphological and structural integrity. Electrochemical assessments were conducted via cyclic voltammetry and square wave voltammetry, with the latter exhibiting an optimal response characterized by a linear range from 0.5 to 20.0 μmol L–1 and a limit of detection (LOD) of 0.030 μmol L–1. Comparative analyses highlighted the sensor’s enhanced performance over conventional materials, with a 10-fold improvement in electron transfer rate, resulting from the higher electroactive area and the inherent functional properties of Sm2O3. The high selectivity was confirmed by testing against common interfering substances, and the sensor demonstrated reliable DA detection in synthetic human serum, achieving recovery rates between 95.27% and 99.39%. The findings suggested that the rGO/Sm2O3 sensor offers a robust, low-cost, and effective solution for DA detection with potential applications in clinical diagnostics and real-time monitoring of neurotransmitter levels in complex biological systems. This advancement underscores the relevance of integrating rare-earth oxides in sensors technology to address selectivity and sensitivity challenges in neurochemical analysis.
A novel flexible supercapacitor device was developed from a polyethylene terephthalate substrate, reused from beverage bottles, and a conductive ink based on carbon black (CB) and cellulose acetate (CA). The weight composition of the conductive ink was evaluated to determine the best mass percentage ratio between CB and CA in terms of capacitive behavior. The evaluation was performed by using different electrochemical techniques: cyclic voltammetry, obtaining the highest capacitance value for the device with the 66.7/33.3 wt% CB/CA in a basic H2SO4 solution, reaching 135.64 F g−1. The device was applied in potentiostatic charge/discharge measurements, achieving values of 2.45 Wh kg−1 for specific energy and around 1000 W kg−1 for specific power. Therefore, corroborated with electrochemical impedance spectroscopy assays, the relatively low-price proposed device presented a suitable performance for application as supercapacitors, being manufactured from reused materials, contributing to the energy storage field enhancement.
1 November 2018 in International Journal of Electrochemical Science