Rodrigo Vieira Blasques

Prof. Dr. Rodrigo Vieira Blasques

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
RBRodrigo Vieira Blasques
Rodrigo Vieira Blasques
POPaulo Roberto de Oliveira
Paulo Roberto de Oliveira
Cristiane KalinkeCristiane Kalinke
Cristiane Kalinke
LBLaís C Brazaca
Laís C Brazaca
Robert CrapnellRobert Crapnell
Robert Crapnell
Bruno Campos JanegitzBruno Campos Janegitz
Bruno Campos Janegitz
The demand for new devices that enable the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) at a relatively low cost and that are fast and feasible to be used as point-of-care is required overtime on a large scale. In this sense, the use of sustainable materials, for example, the bio-based poly (ethylene terephthalate) (Bio-PET) can be an alternative to current standard diagnostics. In this work, we present a flexible disposable printed electrode based on a platinum thin film on Bio-PET as a substrate for the development of a sensor and immunosensor for the monitoring of COVID-19 biomarkers, by the detection of L-cysteine and the SARS-CoV-2 spike protein, respectively. The electrode was applied in conjunction with 3D printing technology to generate a portable and easy-to-analyze device with a low sample volume. For the L-cysteine determination, chronoamperometry was used, which achieved two linear dynamic ranges (LDR) of 3.98−39.0 μmol L−1 and 39.0−145 μmol L−1, and a limit of detection (LOD) of 0.70 μmol L−1. The detection of the SARS-CoV-2 spike protein was achieved by both square wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) by a label-free immunosensor, using potassium ferro-ferricyanide solution as the electrochemical probe. An LDR of 0.70−7.0 and 1.0−30 pmol L−1, with an LOD of 0.70 and 1.0 pmol L−1 were obtained by SWV and EIS, respectively. As a proof of concept, the immunosensor was successfully applied for the detection of the SARS-CoV-2 spike protein in enriched synthetic saliva samples, which demonstrates the potential of using the proposed sensor as an alternative platform for the diagnosis of COVID-19 in the future.

1 March 2020 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
RBRodrigo Vieira Blasques
Rodrigo Vieira Blasques
MPMaria Alessandra Azevedo Pereira
Maria Alessandra Azevedo Pereira
AMAna Marcia Rabelo Vieira Mendes
Ana Marcia Rabelo Vieira Mendes
NFNestor Everton Mendes Filho
Nestor Everton Mendes Filho
WGWolia Costa Gomes
Wolia Costa Gomes
PVPaulo Cesar Mendes Villis
Paulo Cesar Mendes Villis

14 November 2025 in ACS Omega
Verified
Journal Article
Open access
RBRodrigo Vieira Blasques
Rodrigo Vieira Blasques
VSVinicius Aparecido Pedro Oliani da Silva
Vinicius Aparecido Pedro Oliani da Silva
ASAmanda Caroline Nascimento Sousa
Amanda Caroline Nascimento Sousa
TFTatiana Maria Barreto de Freitas
Tatiana Maria Barreto de Freitas
LALeliz Ticona Arenas
Leliz Ticona Arenas
PVPaulo César Mendes Villis
Paulo César Mendes Villis
This work reports the fabrication of a novel electrochemical sensor leveraging reduced graphene oxide (rGO) modified with samarium oxide (Sm2O3) nanoparticles to enhance dopamine (DA) detection. The primary goal was to create a sensitive and selective platform capable of distinguishing DA in complex biological environments. The sensor was synthesized using a hydrothermal method to form rGO/Sm2O3 composites, followed by characterization employing scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), and high-resolution TEM (HR-TEM) and Raman spectroscopy to confirm morphological and structural integrity. Electrochemical assessments were conducted via cyclic voltammetry and square wave voltammetry, with the latter exhibiting an optimal response characterized by a linear range from 0.5 to 20.0 μmol L–1 and a limit of detection (LOD) of 0.030 μmol L–1. Comparative analyses highlighted the sensor’s enhanced performance over conventional materials, with a 10-fold improvement in electron transfer rate, resulting from the higher electroactive area and the inherent functional properties of Sm2O3. The high selectivity was confirmed by testing against common interfering substances, and the sensor demonstrated reliable DA detection in synthetic human serum, achieving recovery rates between 95.27% and 99.39%. The findings suggested that the rGO/Sm2O3 sensor offers a robust, low-cost, and effective solution for DA detection with potential applications in clinical diagnostics and real-time monitoring of neurotransmitter levels in complex biological systems. This advancement underscores the relevance of integrating rare-earth oxides in sensors technology to address selectivity and sensitivity challenges in neurochemical analysis.

7 June 2022 in C
Verified
Journal Article
Open access
PDF file
GDGiovanni G. Daniele
Giovanni G. Daniele
DSDaniel C. de Souza
Daniel C. de Souza
POPaulo Roberto de Oliveira
Paulo Roberto de Oliveira
Luiz Otávio OrzariLuiz Otávio Orzari
Luiz Otávio Orzari
RBRodrigo Vieira Blasques
Rodrigo Vieira Blasques
Bruno Campos JanegitzBruno Campos Janegitz
Bruno Campos Janegitz
A novel flexible supercapacitor device was developed from a polyethylene terephthalate substrate, reused from beverage bottles, and a conductive ink based on carbon black (CB) and cellulose acetate (CA). The weight composition of the conductive ink was evaluated to determine the best mass percentage ratio between CB and CA in terms of capacitive behavior. The evaluation was performed by using different electrochemical techniques: cyclic voltammetry, obtaining the highest capacitance value for the device with the 66.7/33.3 wt% CB/CA in a basic H2SO4 solution, reaching 135.64 F g−1. The device was applied in potentiostatic charge/discharge measurements, achieving values of 2.45 Wh kg−1 for specific energy and around 1000 W kg−1 for specific power. Therefore, corroborated with electrochemical impedance spectroscopy assays, the relatively low-price proposed device presented a suitable performance for application as supercapacitors, being manufactured from reused materials, contributing to the energy storage field enhancement.

1 November 2018 in International Journal of Electrochemical Science
Verified
Journal Article
Open access
PVPaulo Cesar Mendes Villis
Paulo Cesar Mendes Villis
WGWolia Costa Gomes
Wolia Costa Gomes
FSFabricio Brito Silva
Fabricio Brito Silva
DSDiego Rosa dos Santos
Diego Rosa dos Santos
GSGustavo Silveira
Gustavo Silveira
ALAlzira Maria Serpa Lucho
Alzira Maria Serpa Lucho

14 January 2021 in Revista Gestão Inovação e Tecnologias
Verified
Journal Article
Open access
PDF file
U(Universidade Federal do Maranhão (UFMA)
Universidade Federal do Maranhão (UFMA)
RBRibeiro D. B.
Ribeiro D. B.
CCCosta A. R. C.
Costa A. R. C.
KSKano R. S.
Kano R. S.
RBRodrigo Vieira Blasques
Rodrigo Vieira Blasques
NSNunes G. S.
Nunes G. S.
BIOSSENSORES ENZIMÁTICOS PARA DETERMINAÇÃO DE PESTICIDAS