Matheus de Andrade

Mr. Matheus de Andrade

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
KPKi Joo Pahk
Ki Joo Pahk
MAMatheus de Andrade
Matheus de Andrade
PGPierre Gélat
Pierre Gélat
Hyungmin KimHyungmin Kim
Hyungmin Kim
NSNader Saffari
Nader Saffari
In boiling histotripsy, the presence of a boiling vapour bubble and understanding of its dynamic behaviour are crucially important for the initiation of the tissue fractionation process and for the control of the size of a lesion produced. Whilst many in vivo studies have shown the feasibility of using boiling histotripsy in mechanical fractionation of solid tumours, not much is known about the evolution of a boiling vapour bubble in soft tissue induced by boiling histotripsy. The main objective of this present study is therefore to investigate the formation and dynamic behaviour of a boiling vapour bubble which occurs under boiling histotripsy insonation. Numerical and experimental studies on the bubble dynamics induced in optically transparent tissue-mimicking gel phantoms exposed to the field of a 2.0 MHz High Intensity Focused Ultrasound (HIFU) transducer were performed with a high speed camera. The Gilmore-Zener bubble model coupled with the Khokhlov-Zabolotskaya-Kuznetsov and the Bio-heat Transfer equations was used to simulate bubble dynamics driven by boiling histotripsy waveforms (nonlinear-shocked wave excitation) in a viscoelastic medium as functions of surrounding temperature and of tissue elasticity variations. In vivo animal experiments were also conducted to examine cellular structures around a freshly created lesion in the liver resulting from boiling histotripsy. To the best of our knowledge, this is the first study reporting the numerical and experimental evidence of the appearance of rectified bubble growth in a viscoelastic medium. Accounting for tissue phantom elasticity adds a mechanical constraint on vapour bubble growth, which improves the agreement between the simulation and the experimental results. In addition the numerical calculations showed that the asymmetry in a shockwave and water vapour transport can result in rectified bubble growth which could be responsible for HIFU-induced tissue decellularisation. Strain on liver tissue induced by this radial motion can damage liver tissue while preserving blood vessels.

1 July 2019 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
MAMatheus de Andrade
Matheus de Andrade
SHSeyyed Reza Haqshenas
Seyyed Reza Haqshenas
KPKi Joo Pahk
Ki Joo Pahk
NSNader Saffari
Nader Saffari
A phenomenological implementation of Classical Nucleation Theory (CNT) is employed to investigate the connection between high intensity focused ultrasound (HIFU) pressure and temperature fields with the energetic requirements of bubble nucleation. As a case study, boiling histotripsy in tissue-mimicking phantoms is modelled. The physics of key components in the implementation of CNT in HIFU conditions such as the derivation of nucleation pressure thresholds and approximations regarding the surface tension of the liquid are reviewed and discussed. Simulations show that the acoustic pressure is the ultimate trigger for millisecond bubble nucleation in boiling histotripsy, however, HIFU heat deposition facilitates nucleation by lowering nucleation pressure thresholds. Nucleation thus occurs preferentially at the regions of highest heat deposition within the HIFU field. This implies that bubble nucleation subsequent to millisecond HIFU heat deposition can take place at temperatures below 100 °C as long as the focal HIFU peak negative pressure exceeds the temperature-dependent nucleation threshold. It is also found that the magnitude of nucleation pressure thresholds decreases with decreasing frequencies. Overall, results indicate that it is not possible to separate thermal and mechanical effects of HIFU in the nucleation of bubbles for timescales of a few milliseconds. This methodology provides a promising framework for studying time and space dependencies of the energetics of bubble nucleation within a HIFU field.

6 July 2022 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
MAMatheus de Andrade
Matheus de Andrade
RHReza Haqshenas
Reza Haqshenas
KPKi Joo Pahk
Ki Joo Pahk
NSNader Saffari
Nader Saffari
• We implement a CNT model that uses the Rayleigh-Plesset Equation to account for the growth of nuclei. • Enthalpy transport creates cavitation clouds of small bubbles at low temperatures. • Viscosity is the main constraint to nuclei growth in the 0–120 °C temperature range. • The timescales of boiling bubble nucleation are higher than the timescales of cavitation. • It is possible to distinguish the mechanism of nuclei growth via non-dimensional parameters.

14 July 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MAMatheus de Andrade
Matheus de Andrade
SHSeyyed Haqshenas
Seyyed Haqshenas
KPKi Joo Pahk
Ki Joo Pahk
NSNader Saffari
Nader Saffari
This work aims to establish a theoretical framework for the modeling of bubble nucleation in histotripsy. A phenomenological version of the classical nucleation theory was parametrized with histotripsy experimental data, fitting a temperature-dependent activity factor that harmonizes theoretical predictions and experimental data for bubble nucleation at both high and low temperatures. Simulations of histotripsy pressure and temperature fields are then used in order to understand spatial and temporal properties of bubble nucleation at varying sonication conditions. This modeling framework offers a thermodynamic understanding on the role of the ultrasound frequency, waveforms, peak focal pressures, and duty cycle on patterns of ultrasound-induced bubble nucleation. It was found that at temperatures lower than 50 °C, nucleation rates are more appreciable at very large negative pressures such as -30 MPa. For focal peak-negative pressures of -15 MPa, characteristic of boiling histotripsy, nucleation rates grow by 20 orders of magnitude in the temperature interval 60 °C-100 °C.

21 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
SFSaied Froghi
Saied Froghi
AHAndrew Hall
Andrew Hall
AJArif Hanafi Bin Jalal
Arif Hanafi Bin Jalal
MAMatheus de Andrade
Matheus de Andrade
LHLayla Mohammad Hadi
Layla Mohammad Hadi
AQAlberto Quaglia
Alberto Quaglia
Non-invasive therapeutic-focused ultrasound (US) can be used for the mechanical dissociation of tissue and is described as histotripsy. We have performed US histotripsy in viable perfused ex vivo porcine livers as a step in the development of a novel approach to hepatocyte cell transplantation. The histotripsy nidus was created with a 2 MHz single-element focused US transducer, producing 50 pulses of 10 ms duration, with peak positive and negative pressure values of P+ = 77.7 MPa and P− = –13.7 MPaat focus, respectively, and a duty cycle of 1%. Here, we present the histological analysis, including 3D reconstruction of histotripsy sites. Five whole porcine livers were retrieved fresh from the abattoir using human transplant retrieval and cold static preservation techniques and were then perfused using an organ preservation circuit. Whilst under perfusion, histotripsy was performed to randomly selected sites on the live. Fifteen lesional sites were formalin-fixed and paraffin-embedded. Sections were stained with Haematoxylin and Eosin and picro-Sirius red, and they were also stained for reticulin. Additionally, two lesion sites were used for 3D reconstruction. The core of the typical lesion consisted of eosinophilic material associated with reticulin loss, collagen damage including loss of birefringence to fibrous septa, and perilesional portal tracts, including large portal vein branches, but intact peri-lesional hepatic plates. The 3D reconstruction of two histotripsy sites was successful and confirmed the feasibility of this approach to investigate the effects of histotripsy on tissue in detail.

20 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
SFSaied Froghi
Saied Froghi
MAMatheus de Andrade
Matheus de Andrade
LHLayla Mohammad Hadi
Layla Mohammad Hadi
PGPierre Gelat
Pierre Gelat
Hassan RashidiHassan Rashidi
Hassan Rashidi
Brian DavidsonBrian Davidson
Brian Davidson
Introduction: Allogenic hepatocyte transplantation is an attractive alternative to whole-organ transplantation, particularly for the treatment of metabolic disorders and acute liver failure. However, the shortage of human donor organs for cell isolation, the low cell yield from decellularisation regimes, and low engraftment rates from portal administration of donor cells have restricted its clinical application. Using ultrasound histotripsy to provide a nidus in the liver for direct cell transplantation offers a new approach to overcoming key limitations in current cell therapy. We have analysed the liver cavity constituents to assess their potential as a site for cell delivery and implantation. Methods: Using human organ retrieval techniques, pig livers were collected from the abattoir and transported in ice-cold storage to the laboratory. Following 2 h of cold storage, the livers were flushed with organ preservation solution and placed on an organ perfusion circuit to maintain viability. Organs were perfused with Soltran™ organ preservation solution via the portal vein at a temperature of 24–30 °C. The perfusion circuit was oxygenated through equilibration with room air. Perfused livers (n=5) were subjected to ultrasound histotripsy, producing a total of 130 lesions. Lesions were generated by applying 50 pulses at 1 Hz pulse repetition frequency and 1% duty cycle using a single element 2 MHz bowl-shaped transducer (Sonic Concepts, H-148). Following histotripsy, a focal liver lesion was produced, which had a liquid centre. The fluid from each lesion was aspirated and cultured in medium (RPMI) at 37 °C in an incubator. Cell cultures were analysed at 1 and 7 days for cell viability and a live-dead assay was performed. The histotripsy sites were excised following aspiration and H&E staining was used to characterise the liver lesions. Cell morphology was determined by histology. Results: Histotripsy created a subcapsular lesion (~5 mm below the liver capsule; size ranging from 3 to 5 mm), which contained a suspension of cells. On average, 61×104 cells per mL were isolated. Hepatocytes were present in the aspirate, were viable at 24 h post isolation and remained viable in culture for up to 1 week, as determined by phalloidin/DAPI cell viability stains. Cultures up to 21 days revealed metabolically active live hepatocyte. Live-dead assays confirmed hepatocyte viability at 1 week (Day 1: 12% to Day 7: 45% live cells; p < 0.0001), which retained metabolic activity and morphology, confirmed on assay and microscopy. Cell Titre-GloTM showed a peak metabolic activity at 1 week (average luminescence 24.6 RLU; p < 0.0001) post-culture compared with the control (culture medium alone), reduced to 1/3 of peak level (7.85 RLU) by day 21. Conclusions: Histotripsy of the liver allows isolation and culture of hepatocytes with a high rate of viability after 1 week in culture. Reproducing these findings using human livers may lead to wide clinical applications in cell therapy.