Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.
The clinical success of laminate veneers depends upon their marginal discrepancy (MD) and internal gap (IG). This study aims to compare and evaluate the MD, overall discrepancy (OD), absolute marginal discrepancy (AMD), and IG of 3D-printed (Varseosmile TrinQ and Varseosmile Crown Plus) and computer-aided design and manufacturing (CAD/CAM)-milled (Brilliant Crios) laminate veneers using cone-beam computed tomography (CBCT). Thirty maxillary central incisors were prepared and divided randomly into three groups (n = 10). All teeth were scanned for veneer fabrication: Group PVT teeth with 3D-printed Varseosmile TrinQ, Group PVC teeth with 3D-printed Varseosmile Crown Plus, and Group BCM teeth with Brilliant Crios milled veneers. The specimens with respective veneers were scanned using CBCT, and the sectional images were measured for IG, MD, OD, and AMD. The mean values for MD recorded were 0.27, 0.31, and 0.40 for PVT, PVC, and BCM respectively). The mean values for IG recorded were as follows: PVT group—0.24, PVC group—0.28, and BCM group—0.39, and those for OD were as follows: PVT—0.22, PVC—0.32, and BCM—0.41. Intragroup significance was observed for IG and OD (p = 0.001). Findings revealed that milled veneers have a higher IG and MD than 3D-printed veneers, making them less clinically acceptable.
Debonding and detachment of artificial teeth from the denture base is frequently encountered in prosthodontic practice. This study aims to assess the effect of modifications in the ridge-lap surface of denture teeth with various combinations of mechanical and chemical surface treatments with hydrofluoric acid on bond strength with the acrylic denture base resin and to identify the failure modes (adhesive, cohesive, or mixed). Seventy acrylic resin teeth samples were randomly divided into seven groups (n = 10): a control group (unmodified) and six treatment groups, in which various combinations of mechanical and chemical surface treatments were performed. Then, these teeth were attached to a heat-cured denture base resin block at 45° angulation. The acrylized test samples were thermocycled, and the compressive bond strength was evaluated using a universal mechanical testing machine. The results suggest that roughening with diamond burs yields the highest bond strength, whereas etching/grooving and air abrasion result in the lowest bond strength. Acid etching complemented air abrasion to improve bond strength, while negative effects were noted with acid etching in other groups. Furthermore, roughening at the neck portion of the acrylic teeth can be used by the manufacturing companies as a standard to provide higher bond strength while maintaining the esthetics of the anterior teeth.
20 November 2023 in Medical Science Monitor Basic Research
Background: Replicating the 3-dimensional (3D) color of natural teeth in artificial substitutes is challenging. Fixed dental prosthodontics require aesthetic, color-stable provisional restorations. Recent milling and 3D printing digital manufacturing techniques offer improved outcomes. This study assesses color stability in various digital manufacturing methods, tapers, and aging effects on anterior provisional resin restorations. Material/Methods: Two all-ceramic tooth preparations on typodont teeth with 10 degrees and 20 degrees tapers were converted into experimental dies. Forty temporary crowns were manufactured using 3D printing and computer-aided design/computeraided manufacturing (milling). Within these 2 groups, 10 crowns were cemented using a regular and clear provisional cement. All samples were thermocycled to simulate clinical use of 6 months. Color difference formula (CIEDE2000) indicated changes between before and after cementation (AE00[I]) and between after cementation and after thermocycling (AE00[II]). The color change was considered significant in terms of clinically perceptible (AE00 <= 0.62) and acceptable (AE00 <= 2.62) changes. One-way ANOVA (P value of less than 0.05) calculated overall differences, which were established using a Fisher post hoc test. Results: Crowns cemented with clear cement showed fewer color changes irrespective of the manufacturing technique or taper. Notably, only the 10 degrees 3D-printed crown with clear cement had an imperceptible color change at the pre-/post-cementation phase. Meanwhile, the 10 degrees and 20 degrees milled crowns with regular cement exhibited unacceptable color changes after thermocycling. Conclusions: For long-term temporization in the aesthetic zone, properly optimized 3D-printed provisional restorations cemented with clear cement had better color stability.
A well-made provisional fixed prosthesis must present as a preview of the future prosthesis and may also augment the health of the abutments and periodontium. Provisional restorations have been prepared chairside with polymethyl methacrylate (PMMA) since time immemorial. CAD/CAM additive and subtractive technologies have revolutionized the fabrication of interim restorations in dental clinics. The current literature lacks substantial data about retention of provisional crowns manufactured using Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) additive and subtractive techniques with various temporary cements. This in vitro study aims to assess and compare the retention of temporary/provisional anterior crowns based on the combined effect of different digital manufacturing techniques, preparation tapers, and the temporary cements used for cementation. Two maxillary right central incisor typodont teeth were prepared to receive all-ceramic crowns, one with a 10-degree taper and the other with a 20-degree taper. Forty 3D-printed working models with the 10° taper and forty working models with the 20° taper were prepared to receive the temporary crowns. Forty temporary crowns were 3D-printed and forty crowns were milled (20 from each taper group). Kerr Temp-Bond NE conventional cement and Kerr Temp-Bond clear cement were used for cementation in the two groups. The number of samples per test group was 10. All samples were thermocycled and subjected to a universal testing machine to measure the pull-off force until retention loss (N) under tension with a crosshead speed of 5 mm/min. The pull-off force was highest for group 8, i.e., 3D-printed crowns with a 20° taper and cemented with Kerr Temp-Bond clear cement, followed by groups 6, 7, 4, 5, 3, and 2. Group 1, i.e., milled crowns with 10° taper cemented with Kerr Temp-Bond NE conventional cement, exhibited the lowest pull-off retentive force. The clinical selection of long-term provisional crowns fabricated using 3D-printing technology, prepared with 10° or 20° tapers, and cemented with clear cement, is the most favorable in terms of the retention of provisional crowns. 3D-printed provisional crowns can be used as an alternative to conventional and CAD/CAM-milled crowns for long-term provisionalization.
The Impact of Repeated Steam Sterilization Cycles on the Efficacy of Chairside Adjustment Kits for Polishing Monolithic Multi-Layered Zirconia Dental Restoration Material - Article abstract #944502