Nunzio Cennamo

Prof. Nunzio Cennamo

University of Campania Luigi Vanvitelli - Department of Engineering

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2011 in Sensors
Verified
Journal Article
Open access
PDF file
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
DMDavide Massarotti
Davide Massarotti
LCLaura Conte
Laura Conte
LZLuigi Zeni
Luigi Zeni
This paper reports the fabrication and testing of two configurations of optical sensor systems based on Surface Plasmon Resonance (SPR) at the interface of a liquid sample and sandwiched structures realized starting from the exposed core of a Plastic Optical Fiber (POF). The proposed geometries have proven to be suitable for measuring the refractive indexes of liquids whose refractive index falls around 1.35. Furthermore, the proposed sensing head, being low cost and relatively easy to realize, may be very attractive for biosensor implementation.

1 February 2014 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
GDG. D’aGostino
G. D’aGostino
MPM. Pesavento
M. Pesavento
LZLuigi Zeni
Luigi Zeni

1 October 2021 in Talanta
Verified
Journal Article
Closed access
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
Laura PasquardiniLaura Pasquardini
Laura Pasquardini
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
LLLorenzo Lunelli
Lorenzo Lunelli
LVLia Vanzetti
Lia Vanzetti
LZLuigi Zeni
Luigi Zeni

1 November 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
GDG. D’agostino
G. D’agostino
Ramona GalatusRamona Galatus
Ramona Galatus
LBL. Bibbò
L. Bibbò
MPM. Pesavento
M. Pesavento
LZLuigi Zeni
Luigi Zeni

1 August 2015 in Talanta
Verified
Journal Article
Closed access
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
MPMaria Pesavento
Maria Pesavento
LLLorenzo Lunelli
Lorenzo Lunelli
LVLia Vanzetti
Lia Vanzetti
CPCecilia Pederzolli
Cecilia Pederzolli
LPLaura Pasquardini
Laura Pasquardini

5 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
GDGirolamo D’agostino
Girolamo D’agostino
GPGianni Porto
Gianni Porto
ABAdriano Biasiolo
Adriano Biasiolo
CPChiara Perri
Chiara Perri
LZLuigi Zeni
Luigi Zeni
A novel Molecularly Imprinted Polymer (MIP) able to bind perfluorinated compounds, combined with a surface plasmon resonance (SPR) optical fiber platform, is presented. The new MIP receptor has been deposited on a D-shaped plastic optical fiber (POF) covered with a photoresist buffer layer and a thin gold film. The experimental results have shown that the developed SPR-POF-MIP sensor makes it possible to selectively detect the above compounds. In this work, we present the results obtained with perfluorooctanoate (PFOA) compound, and they hold true when obtained with a perfluorinated alkylated substances (PFAs) mixture sample. The sensor’s response is the same for PFOA, perfluorooctanesulfonate (PFOS) or PFA contaminants in the C4–C11 range. We have also tested a sensor based on a non-imprinted polymer (NIP) on the same SPR in a D-shaped POF platform. The limit of detection (LOD) of the developed chemical sensor was 0.13 ppb. It is similar to the one obtained by the configuration based on a specific antibody for PFOA/PFOS exploiting the same SPR-POF platform, already reported in literature. The advantage of an MIP receptor is that it presents a better stability out of the native environment, very good reproducibility, low cost and, furthermore, it can be directly deposited on the gold layer, without modifying the metal surface by functionalizing procedures.