This article describes 1D extension tests on bovine collagen samples (8% collagen in water). At such a high collagen concentration, the mechanical properties of semi-solid samples can be approximated by hyperelastic models (two-parametric HGO and Misof models were used), or simply by Hooke’s law and the modulus of elasticity E. The experiments confirm a significant increase in the E-modulus of the samples irradiated with high-energy electrons. The modulus E ~ 9 kPa of non-irradiated samples increases monotonically up to E ~ 250 kPa for samples absorbing an e-beam dose of ~3300 Gy. This amplification is attributed to the formation of cross-links by irradiation. However, E-modulus can be increased not only by irradiation but also by exposure to a high strain rate. For example, soft isotropic collagen extruded through a 200 mm long capillary increases the modulus of elasticity from 9 kPa to 30 kPa, and the increase is almost isotropic. This stiffening occurs when the corrugated collagen fibers are straightened and are aligned in the flow direction. It seems that the permanent structural changes caused by extrusion mitigate the effects of the ex post applied irradiation. Irradiation of extruded samples by 3300 Gy increases the modulus of E-elasticity only three times (from 30 kPa to approximately 90 kPa). Extruded and ex post irradiated samples show slight anisotropy (the stiffness in the longitudinal direction is on an average greater than the transverse stiffness).
The objective of this study is to provide a straightforward generalized simple and quick method for the prediction of the friction factor for fully developed laminar flow of viscoplastic shear-thinning fluids in non-circular channels of regular cross-sections. The most frequently represented substances processed under these conditions are polymers in the processing and plastics industry. A generalized approximate method was proposed to express the relationship between the friction factor and the Reynolds number for the Herschel–Bulkley rheological model. This method uses the generalized Reynolds number for power-law fluids. Moreover, an additional simplified method for rapid engineering calculations was obtained as well. The suggested method was verified by comparing experimental data for concentric annulus found in the literature and results from simulations for concentric annulus, rectangular, square duct with a central cylindrical core and elliptical cross-sections. The results showed that the suggested methods enable us to estimate the friction factor with high accuracy for the investigated geometries.
Flow inversion, transferring a liquid from the wall region toward the center of the pipe or from the axis toward the heat transfer surface, improves heat transfer in the laminar flow regime. While a fully developed velocity profile is quickly established, a thin thermal boundary layer is preserved for a considerable distance in the pipe behind the flow inverter for highly viscous liquids. Thus the pressure drop is increased only locally (by the inverter itself), while heat transfer enhancement is also seen in a long straight section of the pipe. Two original flow inverter designs were tested in a long pipe (3 m in length) heated by condensing steam, using starch molasses as a working medium. Experiments carried out in the range of Reynolds number 4–60 and Graetz number 150–700 resulted in an increase of 20–35% in the heat transfer coefficient, accompanied by a 30–40% increase in the pressure drop. The experimental results confirm the numerical model prediction (within an extended Reynolds number range starting from 0.1). Thus an almost 40% increase in heat transfer can be expected at the optimal Graetz number in the range 50–100, using only one flow inverter located in the middle of a sufficiently long pipe.