Since the power grid grows and the necessity for higher system efficiency is due to the increasing number of renewable energy penetrations, power system operators need a fast and efficient method of operating the power system. One of the main problems in a modern power system operation that needs to be resolved is optimal power flow (OPF). OPF is an efficient generator scheduling method to meet energy demands with the aim of minimizing the total production cost of power plants while maintaining system stability, security, and reliability. This paper proposes a new method to solve OPF by using incremental particle swarm optimization (IPSO). IPSO is a new algorithm of particle swarm optimization (PSO) that modifies the PSO structure by increasing the particle size, where each particle changes its position to determine its optimal position. The advantage of IPSO is that the population increases with each iteration so that the optimization process becomes faster. The results of the research on optimal power flow for energy generation costs, system voltage stability, and losses obtained by the IPSO method are superior to the conventional PSO method.
1 October 2019 in Journal of Physics: Conference Series
This study aims at giving descriptive computation of determining the optimal location and capacity of Distributed Generation (DG) for the compensation of active and reactive power on the electric power system using Artificial Bee Colony and minimizing the power losses. It employed the IEEE 34-Bus Reliability Test System (RTS) as the case study focusing on the determination of the location and capacity of Distributed Generation using Artificial Bee Colony algorithm. The data analysis shows that the placement of DG on the IEEE 34-bus system employing ABC can reduce the real power losses and the real power losses at the optimal location and capacity is minimum.
Distributed energy resource (DER) has become an effective attempt in promoting use of renewable energy resources for electricity generation. The core intention of this study is to expand an approach for optimally placing several DER units to attain the most stable performance of the system and the greatest power losses decrease. The recommended technique is established on two analytical methods for analyzing voltage stability: the new modified modal analysis (MMA) and the continuation power flow (CPF) or MMA–CPF methods. The MMA evaluates voltage stability by considering incremental connection relating voltage and active power, which includes the eigenvalue and the related eigenvectors computed from the reduced modified Jacobian matrix. Furthermore, an active participation factor (APF) is computed from the eigenvectors of the reduced modified Jacobian matrix. The CPF method uses a predictor–corrector stepping pattern to reach the solution track and compute the tangent vector sensitivity (TVS). Both APF and TVS indicate each load bus sensitivity in the network. In addition, an objective function regarding losses decrease and eigenvalue is expressed to calculate the best bus position for DER allocation. The proposed MMA–CPF technique has been assessed on a 34-bus RDN and the outcomes demonstrate the effectiveness of the proposed scheme.
This study proposes the integration of a hybrid Proof of Work/Proof of Stake (PoW/PoS) consensus mechanism with a Long Short-Term Memory (LSTM) model for anomaly detection in blockchain-based microgrids. The hybrid PoW/PoS model is designed to address common issues in blockchain systems, such as 51% attacks, double-spending, and high energy consumption, by optimizing energy usage and enhancing security. Simulation results show that the system can process transactions with an average throughput of 37.25 transactions per second (TPS), an average latency of 26.84 milliseconds per transaction (ms/tx), and extremely efficient energy consumption per transaction (0.01 kWh/tx). The LSTM model applied for anomaly detection achieves an 89.10% detection rate, a 0.00% false positive rate, and a 0.12 s recovery time, indicating the system's reliability in facing attacks. The hybrid PoW/PoS system demonstrates advantages in both energy efficiency and resilience to attacks compared to individual PoW and PoS systems. This research contributes to the development of safer, more efficient, and scalable blockchain-based microgrids by integrating Artificial Intelligence (AI) to strengthen the system against anomalies and threats.
1 October 2019 in Journal of Physics: Conference Series
Economic dispatch is a method to compute the amount of power that must be generated from each generator units to meet a specific load while minimizing its operating costs. This study performed economic dispatch for the Jeneponto Thermal Power Plant, in the Jeneponto Regency, South Sulawesi Province, Indonesia by using the Lagrange multiplier method. The results of this study showed that by performing economic dispatch, it is effective in minimizing the fuel cost compared to the existing dispatch. The overall savings that can be obtained for this case study is 4.5% for the specific case study.