This study investigated the effects of clogging in Pervious Concrete (PC) from January 2015 to December 2022. Three different PC mixtures were used, which included coarse aggregate (4.75-9.5 mm), fine aggregate (0-20% weight of coarse aggregate), cement (340 kg/m3), and w/c ratio of 0.35. The samples were tested for compressive strength, permeability, and porosity. The best PC mixture containing 10% fine aggregate was selected for monitoring clogging over time. This mixture had a compressive strength of 24.7 MPa, permeability of 1.19 mm/s, and void content of 13.96%. A large-scale prototype of PC10 (10% of fine aggregate) measuring 3.5 m in length, 1.7 m in width, and 0.20 m in depth was constructed in Mashhad City, Iran. The in-place infiltration rate was measured on a monthly basis as the PC experienced different rainfall levels. The results showed that due to clogging, the infiltration rate was reduced by an average of 10% for the first four years of the experiments. This was followed by a substantial reduction of 20% in 2019 and 16.75% in 2020. Due to a high level of clogging, the infiltration rate was reduced by 5.02% and 2.23% in 2021 and 2022, respectively. However, the system still has the capacity to infiltrate at 1.14 mm/s. Although no maintenance was performed on the PC system, its efficiency and lifespan were substantially reduced. Nonetheless, the system can still be considered as an effective solution for stormwater management.
1 January 2021 in Advances in Materials Science and Engineering
Today, most countries around the globe are facing water resources restrictions, and it is predicted freshwater resources will be more valuable than oil wells in the next century. In the present study, the ability of lead removal using both powders of Mespilus germanica (MG) and Tribulus terrestris (TT) seeds and optimization of the adsorption process have been investigated. Four main parameters were selected for experimental design, namely, pH, time of contact, the ratio of adsorbent to solution volume, and initial concentration of lead in solution, and the optimization of effective parameters on lead adsorption was performed based on central composite design (CCD) under response surface methodology (RSM). According to the statistical results, the proposed model for MG and TT is confirmed with 0.95 and 0.96 correlation coefficient and 0.92 and 0.94 adjusted correlation coefficient, respectively. The results of parameter optimization also showed that both adsorbents have the acceptable ability to adsorb lead from aqueous solutions. Under the optimum conditions with the initial lead concentration of 10 mg/l, MG powder had better performance in lead adsorption of 96.04%, and TT powder also had an acceptive performance of 93.20%. Moreover, the MG and TT adsorbents have the most accordance with the Freundlich and D‐R isotherms, respectively.
6 August 2025 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
Adsorbent Pervious Concrete (APC) is ordinary pervious concrete (PC) that contains inexpensive adsorbents for the removal of contaminants from stormwater and wastewater. APC is a sustainable solution with manifold environmental advantages. These desirable outcomes of APC in reducing stormwater and wastewater pollution require an applicable response from researchers to address not only the optimized mixture design, strength, and physical properties of APC but also the effect of different types of adsorbents on engineering properties and environmental aspects of this system. These critical issues are the topic of this review paper. Laboratory results relevant to mixture design, compressive strength, porosity, and permeability of APC and their interrelationship are discussed in great detail. The effect of different types of low-cost adsorbents, such as minerals, industry waste, and nanoparticles, which are either added to the APC mixture or substituted by the proportion of coarse aggregate or cement, is reviewed. Based on this state-of-the-art review of the abovementioned issues, further investigations of the usage of APC in wastewater treatment, along with studying the engineering properties, are recommended. Graphical Abstract