Jiyong Wang

Dr. Jiyong Wang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2024 in PhotoniX
Verified
Journal Article
Open access
PDF file
CZChenxi Zhang
Chenxi Zhang
LZLei Zhang
Lei Zhang
HZHe Zhang
He Zhang
Bo FuBo Fu
Bo Fu
JWJiyong Wang
Jiyong Wang
MQMin Qiu
Min Qiu
Pulsed polarized vortex beams, a special form of structured light, are generated by tailoring the light beam spatiotemporally and witness the growing application demands in nonlinear optics such as ultrafast laser processing and surface plasma excitation. However, existing techniques for generating polarized vortex beams suffer from either low compactness due to the use of bulky components or limited controlment of pulse performance. Here, an all-fiber technique combining plasmonic metafibers with mode conversion method is harnessed to generate high-performance pulsed polarized vortex beams. Plasmonic metafibers are utilized as saturable absorbers to produce Q-switched pulses with micro-second duration, while the offset splicing method is employed to partially convert the fundamental transverse mode (LP $$_{01}$$ 01 ) to higher-order mode (LP $$_{11}$$ 11 ). Eventually, a polarized vortex beams laser is achieved at the telecom band with a repetition frequency of 116.0 kHz. The impact of geometrical parameters including period of metafibers and offset of splicing on the spatiotemporal properties of pulsed polarized vortex beams is systematically investigated. Our findings could pave the way for design, control and generation of all-fiber pulsed polarized vortex beams, and also offer insights into the development of other types of structured laser sources.

22 August 2023 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
LZLei Zhang
Lei Zhang
XSXinyu Sun
Xinyu Sun
HYHongyan Yu
Hongyan Yu
NDNiping Deng
Niping Deng
FQFeng Qiu
Feng Qiu
MQMin Qiu
Min Qiu
Digitalizing optical signals through electric driving signals, electro-optic modulators (EOMs) are one of the cardinal elements in modern optical communications. Most of current EOM devices are targeting on-chip integrations, which routinely suffer from high coupling losses, complex optical alignments and single-band operations. In this study, we for the first time integrate a lumped EOM device on the endfaces of a single-mode optical fiber jumper for fast amplitude modulations. Profiting from ultrathin and high quality-factor plasmonic metasurfaces, nanofabrication-friendly and highly efficient EO polymers and coupling-free connections with fiber networks, our EOM is demonstrated to allow dual-band operations (telecom O band and S band) and high-speed modulations (~1 GHz at a bias voltage of ±9 V). This work offers an avenue to ‘plug-and-play’ implementations of EO devices and ultracompact “all-in-fibers” optical systems for communications, imaging, sensing and many others.

15 August 2024 in PhotoniX
Verified
Journal Article
Open access
PDF file
LZLei Zhang
Lei Zhang
XSXinggang Shang
Xinggang Shang
SCSimin Cao
Simin Cao
QJQiannan Jia
Qiannan Jia
JWJiyong Wang
Jiyong Wang
MQMin Qiu
Min Qiu
Refractive index (RI) sensors play an important role in various applications including biomedical analysis and food processing industries. However, developing RI sensors with both high resolution and wide linear range remains a great challenge due to the tradeoff between quality (Q) factor and free spectral range (FSR) of resonance mode. Herein, the optical steelyard principle is presented to address this challenge by synergizing resonances from the Fabry–Perot (FP) cavity and metasurface, integrated in a hybrid configuration form on the end facet of optical fibers. Specifically, the FP resonance acting like the scale beam, offers high resolution while the plasmonic resonance acting like the weight, provides a wide linear range. Featuring asymmetric Fano spectrum due to modal coupling between these two resonances, a high Q value (~ 3829 in liquid) and a sensing resolution (figure of merit) of 2664 RIU−1 are experimentally demonstrated. Meanwhile, a wide RI sensing range (1.330–1.430 in the simulation and 1.3403–1.3757 in the experiment) is realized, corresponding to a spectral shift across several FSRs (four and two FSRs in the simulation and experiment, respectively). The proposed steelyard RI sensing strategy is promising in versatile monitoring applications, e.g., water salinity/turbidity and biomedical reaction process, and could be extended to other types of sensors calling for both high resolution and wide linear range.

5 October 2023 in PhotoniX
Verified
Journal Article
Open access
PDF file
JWJiyong Wang
Jiyong Wang
LZLei Zhang
Lei Zhang
MQMin Qiu
Min Qiu
The study on the nonlinear optical responses arising from plasmonic nanoantennas, known as nonlinear plasmonics, has been massively investigated in recent years. Among the most basic nonlinear optical responses, second-harmonic generation (SHG) and multiphoton photoluminescence (MPL), two-photon photoluminescence in particular, has aroused extensive interests, due to their distinct properties of being ultrasensitive to the spatial symmetry and ultrafast response time of hot electrons. In this review, we give insights into fundamental roles dominating the radiations of such nonlinear optical processes and their recent research advances. Different from other reviews on nonlinear plasmonics, which mainly focused on parametric processes, this review pays equal attentions to the incoherent process of MPL. An in-depth description on the excitation and emission processes of MPL in accordance with recent studies is fully presented. By using the high ‘symmetry rule’ of SHG and ultrafast response time of MPL, advanced applications in surface enhanced spectroscopy, ultra-sensitive photodetector, biosensor and ultrafast laser pulses are highlighted in the end.

20 November 2019 in Nanoscale
Verified
Journal Article
Closed access
PDF file
JWJiyong Wang
Jiyong Wang
JBJérémy Butet
Jérémy Butet
GBGabriel David Bernasconi
Gabriel David Bernasconi
ABAnne-Laure Baudrion
Anne-Laure Baudrion
GLGaëtan Lévêque
Gaëtan Lévêque
DZDai Zhang
Dai Zhang
Strong second-harmonic generation from Au–Al heterodimers with a nanogap is observed and predicted, mainly attributed to coupling of plasmonic resonance in the fundamental field and synergistic driving from constituting nanoantennas in the SH field.

26 November 2022 in Water
Verified
Journal Article
Open access
PDF file
XTXiaoqing TIAN
Xiaoqing TIAN
ZWzhenlin wang
zhenlin wang
ETElias Taalab
Elias Taalab
BZBaofeng Zhang
Baofeng Zhang
XLXiaodong Li
Xiaodong Li
ZZZefei Zhu
Zefei Zhu
With the growth of industrialization in recent years, the quality of drinking water has been a great concern due to increasing water pollution from industries and industrial farming. Many monitoring stations are constructed near drinking water sources for the purpose of fast reactions to water pollution. Due to the relatively low sampling frequencies in practice, mathematic prediction models are clearly needed for such monitoring stations to reduce the delay between the time points of pollution occurrences and water quality assessments. In this work, 2190 sets of monitoring data from automatic water quality monitoring stations in the Qiandao Lake, China from 2019 to 2020 were collected, and served as training samples for prediction models. A grey relation analysis-enhanced long short-term memory (GRA-LSTM) algorithm was used to predict the key parameters of drinking water quality. In comparison with conventional LSTM models, the mean absolute errors (MAEs) to predict the four parameters of water quality, i.e., dissolved oxygen (DO), permanganate index (COD), total phosphorus (TP), and potential of hydrogen (pH), were reduced by 23.03%, 10.71%, 7.54%, and 43.06%, respectively, using our GRA-LSTM algorithm, while the corresponding root mean square errors (RMSEs) were reduced by 24.47%, 5.28%, 6.92%, and 35.89%, respectively. Such an algorithm applies to predictions of events with small amounts of data, but with high parametric dimensions. The GRA-LSTM algorithm offers data support for subsequent water quality monitoring and early warnings of polluting water sources, making significant contributions to real-time water management in basins.