Li Li

Mrs. Li Li


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2018 in Discover Nano
Verified
Journal Article
Open access
PDF file
NTNian Tang
Nian Tang
THTingyu He
Tingyu He
JLJie Liu
Jie Liu
LLLi Li
Li Li
HSHan Shi
Han Shi
ZYZhixiang Ye
Zhixiang Ye
The interlamellar spacing of layered double hydroxides (LDHs) was enlarged by dodecyl sulfonate ions firstly, and then, (3-aminopropyl)triethoxysilane (APS) was chemically grafted (APS/LDHs). The structural characteristics and thermal stability of these prepared samples were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), reflectance Fourier transform infrared spectrometer (FTIR), thermogravimetric analysis (TG), and elemental analysis (EA) respectively. The CO2 adsorption performance was investigated adopting TG and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). The results presented that the CO2 adsorption capacity on APS/LDHs was as high as 90 mg/g and showed no obvious reduction during a five cyclic adsorption-desorption test, indicating its superior performance stability. The DRIFTS results showed that both carbamates and weakly bounded CO2 species were generated on APS/LDHs. The weakly adsorbed species was due to the different local chemical environment for CO2 capture provided by the surface moieties of LDHs like free silanol and hydrogen bonds.

22 December 2022 in Polymers
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
QLQi Li
Qi Li
SXShuxin Xu
Shuxin Xu
LRLiu Rui
Liu Rui
MDManling Dong
Manling Dong
XJXingliang Jiang
Xingliang Jiang
Resin-impregnated paper (RIP) bushing has gained significant interest due to its extended application in Extra High Voltage (EHV) and Ultra High Voltage (UHV) electricity transmission systems. However, the design criterion of its overall structure, the geometry parameters of the condenser layers, and stress release devices, etc., are still not fully understood. This article proposes a unique electric field optimization technique to integrate both the analytical and the numerical methods. The charge simulation method (CSM) is employed to create the overall equipotential surface, within which the finite element analysis (FEA) is adapted to study the localized field enhancement effects, taking into consideration the multi-physics coupled fields. A case study is performed on an actual UHV bushing. The results are compared to the traditional methods, to demonstrate the benefit of the hybrid method.

9 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
MWMENG Wei
MENG Wei
QLQi Li
Qi Li
YWYifan Wang
Yifan Wang
XZXiaoguang Zheng
Xiaoguang Zheng
HWHongbin Wang
Hongbin Wang
The audible noise (AN) of DC transmission lines is a crucial factor affecting environmental assessment and electromagnetic design. In recent years, the public has paid increasing attention to the audible noise after the emergence of the HVDC technique. This paper emphatically reviewed the work investigating audible noise characteristics in both time and frequency domains, especially the correlation between sound and discharge. The proposed mechanisms of DC audible noise and the mitigating techniques are summarized, including the noise generation process, the physical models, the measurement method, and the mitigating technologies. It is found that the existing literature mainly focused on the prediction and characteristics of AN, the environmental factors which influence AN, and the methods to minimize AN emission. However, existing achievements still need to be improved to fully understand the mechanism of AN generation and solve the adaptability problem of AN prediction methods. The following aspects are valuable in future research: The correlation between audible noise and other corona effects will help solve the problem of difficulty in measuring audible noise in field condition; The corona discharge mechanism and weather resistance anti-corona coating when raindrops are attached to the surface of the transmission line, which will help guide the development and application of anti-corona coatings for the transmission line. Future research should also understand the mechanism of sound wave generation when considering the space charge effect.

31 August 2023 in Coatings
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
JXJunhuang Xu
Junhuang Xu
YWYifan Wang
Yifan Wang
MWMENG Wei
MENG Wei
SFShengping Fan
Shengping Fan
Hongqiang LiHongqiang Li
Hongqiang Li
In recent years, the number of high-voltage transmission lines has sharply increased with the rapid development of modern industry. However, a corona discharge phenomenon often occurs on the exposed high-voltage transmission lines, leading to energy loss and noise pollution. Herein, we have proposed a facile spraying method to prepare a superhydrophobic and thermally conductive coating to restrain the corona discharge phenomenon of high-voltage transmission lines, with vinyl silicone oil and hydrogen silicone oil as the main materials and modified boron nitride (BN) as a thermal conductive filler. The obtained composite coating exhibited superhydrophobicity, with a high water contact angle of 162°. In addition, the coating also showed a good self-cleaning capability, non-adhesion capability, mechanical stability, and chemical stability. Owing to the construction of the thermally conductive pathways with BN, the thermal conductivity of the coating reached 1.05 W/m·K, which was beneficial to quickly dissipating the heat generated by the current heating effect. Moreover, the corona losses of the positive and negative electrodes under simulated rainy conditions were decreased by 7.43% and 8.05%, respectively. The findings of our work have provided a new strategy to effectively restrain the corona discharge phenomenon of transmission lines, showing great application potential in the field of high-voltage power networks.

15 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
QLQi Li
Qi Li
LRLiu Rui
Liu Rui
LLLi Li
Li Li
XSXiaofan Song
Xiaofan Song
YWYifan Wang
Yifan Wang
XJXingliang Jiang
Xingliang Jiang
The dynamic behaviour of rain droplets on the insulator surface is a key measure to its reliability and performance. This is due to the fact that the presence and motion of rain droplets cause intensive discharge activities, such as corona and low current arcing, which accelerate the ageing process and flashovers. This article aims to investigate and characterize the movement of a rain droplet placed on an inclined insulator surface subject to an intensive electric field. The rain droplets’ movement on hydrophobic surfaces in the absence of an electric field is investigated. A high speed camera is used to capture the footage and finite element method (FEM) is used to simulate the multi-physics phenomenon on two polymeric surfaces, namely, silicon rubber (SiR) and PTFE (polytetrafluoroethylene). A ‘creepage’ motion was observed. The inception of motion and the movement speed are analysed in correlation with various surface conditions. Models are established to estimate the moisture and potential discharge characteristics on the inclined polymeric surfaces. They are further utilized to analyse the actual insulators subject to wet conditions.

8 July 2026 in Electronics
Verified
Journal Article
Open access
PDF file
QLQifei Lv
Qifei Lv
YLYuhao Liu
Yuhao Liu
JHJinhua Huang
Jinhua Huang
HLHuiying Lu
Huiying Lu
LLLi Li
Li Li
Xianbo WangXianbo Wang
Xianbo Wang
Following the occurrence of a substation fault, alarm systems frequently exhibit issues such as high-density redundancy, spurious alerts, undetected alarms, and temporal inconsistencies. In addition, the effective integration of heterogeneous multi-source data—including fault waveform records and phasor measurement unit (PMU) streams—remains a nontrivial challenge, further impeding the accuracy of fault diagnosis. To address these limitations, this paper proposes an enhanced framework for multi-source fault event modeling and candidate scenario generation based on an extended temporal constraint network. First, protection operations, circuit breaker status transitions, transient waveform features, and PMU-derived dynamic parameters are abstracted as fault event nodes. On this basis, an event representation model is constructed, incorporating event type, associated equipment, temporal attributes, data source identifiers, and reliability coefficients. Second, the conventional temporal constraint network is refined by jointly embedding temporal constraints, distance constraints, and event confidence metrics, thereby enabling the characterization of uncertain causal-temporal dependencies between fault origins and multi-source observations. Third, a dynamic time-window mechanism is introduced to perform online event clustering, followed by reverse temporal reasoning to generate a set of candidate fault scenarios. These scenarios are subsequently verified, merged, and ranked with reference to waveform and PMU data, facilitating the identification of false alarms, missing alarms, and timestamp anomalies. Finally, case studies conducted on a 220 kV substation and its interconnected transmission network demonstrate that the proposed method achieves a correct scenario coverage rate of 96.8%, a candidate scenario compression rate of 68.7%, and an abnormal alarm recognition accuracy of 89.5%, while sustaining an average scenario generation time of 0.28 s.