Takumi Yoshimura

Prof. Dr. Takumi Yoshimura


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Toshiyo TamuraToshiyo Tamura
Toshiyo Tamura
MHMing Huang
Ming Huang
TYTakumi Yoshimura
Takumi Yoshimura
SUShinjiro Umezu
Shinjiro Umezu
TOToru Ogata
Toru Ogata
Heatstroke is a concern during sudden heat waves. We designed and prototyped an Internet of Things system for heatstroke prevention, which integrates physiological information, including deep body temperature (DBT), based on the dual-heat-flux method. A dual-heat-flux thermometer developed to monitor DBT in real-time was also evaluated. Real-time readings from the thermometer are stored on a cloud platform and processed by a decision rule, which can alert the user to heatstroke. Although the validation of the system is ongoing, its feasibility is demonstrated in a preliminary experiment.

24 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KHKenta Hayashi
Kenta Hayashi
YMYuka Maeda
Yuka Maeda
TYTakumi Yoshimura
Takumi Yoshimura
MHMing Huang
Ming Huang
Toshiyo TamuraToshiyo Tamura
Toshiyo Tamura
Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 ± 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.

1 January 2023 in Journal of the Japan Society of Applied Electromagnetics and Mechanics
Verified
Journal Article
Open access
PDF file
TYTakumi Yoshimura
Takumi Yoshimura
MHMing Huang
Ming Huang
TTToshiyo Tamura
Toshiyo Tamura
In recent years, the importance of measuring body temperature has increased due to the rise in heat stroke from global warming and COVID-19. In addition, smartwatch manufacturers are releasing smartwatches that can measure skin temperature on the wrist, and demand for body temperature measurement is increasing in the health care field. This paper provides an overview of conventional temperature measurement methods and the latest trends in thermometer sensors for future healthcare applications.