This study compared body composition by dual-energy X-ray absorptiometry (DEXA; Lunar DPX-L) with that via a four-compartment (4C; water, bone mineral mass, fat, and residual) model. Relative body fat was determined for 152 healthy adults [30.0 ± 11.1 (SD) yr; 75.10 ± 14.88 kg; 176.3 ± 8.7 cm] aged from 18 to 59 yr. The 4C approach [20.7% body fat (%BF)] resulted in a significantly ( P < 0.001) higher mean %BF compared with DEXA (18.9% BF), with intraindividual variations ranging from −2.6 to 7.3% BF. Linear regression and a Bland and Altman plot demonstrated the tendency for DEXA to progressively underestimate the %BF of leaner individuals compared with the criterion 4C model (4C %BF = 0.862 × DEXA %BF + 4.417; r 2 = 0.952, standard error of estimate = 1.6% BF). This bias was not attributable to variations in fat-free mass hydration but may have been due to beam-hardening errors that resulted from differences in anterior-posterior tissue thickness.
24 July 2003 in European Journal of Clinical Nutrition
Based on persistent reports of low oxygen consumption VO(2) from Medical Graphics CPX/D metabolic carts, we compared the CPX/D against an automated Douglas bag system. Twelve male athletes completed three, randomized 25-min bouts (5 min at 100, 150, 200, 250, and 300 W) on a cycle ergometer with intervening 30-min rests. One bout was measured on each of the CPX/D, the CPX/D with altered software (CPX/DDelta), and an automated Douglas bag system at Flinders University (FU). The CPX/DDelta software alteration was an apparent lag time correction factor of 60 ms. For the CPX/D, both VO(2) and VCO(2) were significantly lower than the FU system at 100-300 W, and the relative differences ranged -10.7 to -12.0% and -7.7 to -8.2%, respectively. Altering the software approximately halved the VO(2) discrepancy between the CPX/DDelta and FU systems. When data from all five workloads were pooled, V(E) of the CPX/D (67.2 +/- 26.4 L x min-1) and CPX/DDelta (67.5 +/- 26.9 L x min-1) were significantly lower than for the FU system (70.5 +/- 27.1 L x min-1); and at 300 W, the relative differences were -4.0% and -3.4% for the CPX/D and CPX/DDelta, respectively. Altering the software changed the pooled %O(2) from 16.24 +/- 0.40% for the CPX/D to 16.04 +/- 0.39% for the CPX/DDelta, and these were significantly different than pooled data for the FU system (16.15 +/- 0.39%). During submaximal exercise, the CPX/D yields VO(2) values that are approximately 11% lower than the criterion system, and the source of the discrepancy does not appear to be primarily related to volume measurement. A disturbing observation is that factory defaults for the lag time use different correction factors, which vary by 60 ms and this significantly alters VO(2) and VCO(2).
1 March 2001 in European Journal of Clinical Nutrition
Objectives: The aims of this study were: (a) to generate regression equations for predicting the resting metabolic rate (RMR) of 18 to 30-y-old Australian males from age, height, mass and fat-free mass (FFM); and (b) cross-validate RMR prediction equations, which are frequently used in Australia, against our measured and predicted values. Design: A power analysis demonstrated that 38 subjects would enable us to detect (α=0.05, power=0.80) statistically and physiologically significant differences of 8% between our predicted/measured RMRs and those predicted from the equations of other investigators. Subjects: Thirty-eight males (X̄±s.d.: 24.3±3.3 y; 85.04±13.82 kg; 180.6±8.3 cm) were recruited from advertisements placed in a university newsletter and on community centre noticeboards. Interventions: The following measurements were conducted: skinfold thicknesses, RMR using open circuit indirect calorimetry and FFM via a four-compartment (fat mass, total body water, bone mineral mass and residual) body composition model. Results: A multiple regression equation using the easily measured predictors of mass, height and age correlated 0.841 with RMR and the SEE was 521 kJ/day. Inclusion of FFM as a predictor increased both the R and the precision of prediction, but there was virtually no difference between FFM via the four-compartment model (R=0.893, SEE=433 kJ/day) and that predicted from skinfold thicknesses (R=0.886, SEE=440 kJ/day). The regression equations of Harris & Benedict (1919) and Schofield (1985) all overestimated the mean RMR of our subjects by 518–600 kJ/day (P<0.001) and these errors were relatively constant across the range of measured RMR. The equations of Hayter & Henry (1994) and Piers et al (1997) only produced physiologically significant errors at the lower end of our range of measurement. Conclusions: Equations need to be generated from a large database for the prediction of the RMR of 18 to 30-y-old Australian males and FFM estimated from the regression of the sum of skinfold thicknesses on FFM via the four compartment body composition model needs to be further explored as an expedient RMR predictor. Sponsorship: Australian Research Council (small grants scheme). European Journal of Clinical Nutrition (2001) 55, 145–152