MAÍRA MARQUES RIBEIRO

Prof. MAÍRA MARQUES RIBEIRO

Hospital das Clínicas da Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Revista Latino-Americana de Enfermagem
Verified
Journal Article
Open access
PDF file
MRMAÍRA MARQUES RIBEIRO
MAÍRA MARQUES RIBEIRO
VNVerena Ashley Neumann
Verena Ashley Neumann
MPMaria Clara Padoveze
Maria Clara Padoveze
KGKazuko Uchikawa Graziano
Kazuko Uchikawa Graziano
Objective: to assess the efficacy and the effectiveness of 60-80% alcohol (v/v) in the disinfection of semi-critical materials which were either previously cleaned or not.Method: studies obtained from BIREME, IBECS, MEDLINE, ScIELO, PubMed, Ask Medline web portals, and references from other studies. Criteria were created to assess the methodological quality of articles. Out of the 906 studies found, 14 have been included.Results: after materials were disinfected with alcohol, microorganisms were detected in 104/282 (36.9%) effectiveness tests and in 23/92 (25.0%) efficacy tests that were conducted. In the field studies, disinfection was not achieved for 74/218 (33.9%) of the products that were submitted to previous cleaning and for 30/64 (46.9%) of the ones which were not submitted to previous cleaning. In the experimental studies, alcohol disinfection was not efficacy in 11/30 (36.7%) and 12/62 (19.4%) of products, respectively. The studies were not found to have followed standardized methods.Conclusion: disinfection of semi-critical products with alcohol 70% - or in an approximate concentration - cannot be recommended to all health care products in an unrestricted way. However, according to the type of semi-critical product, disinfection can be attained with or without previous cleaning.

1 December 2012 in American Journal of Infection Control
Verified
Journal Article
Closed access
MRMAÍRA MARQUES RIBEIRO
MAÍRA MARQUES RIBEIRO
AOAdriana Cristina de Oliveira
Adriana Cristina de Oliveira

1 March 2013 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
MRMAÍRA MARQUES RIBEIRO
MAÍRA MARQUES RIBEIRO
AOAdriana Cristina de Oliveira
Adriana Cristina de Oliveira
SRSilma Maria Cunha Pinheiro Ribeiro
Silma Maria Cunha Pinheiro Ribeiro
Evandro WatanabeEvandro Watanabe
Evandro Watanabe
MSMaria Aparecida de Resende Stoianoff
Maria Aparecida de Resende Stoianoff
JFJosé Antonio Guimarāes Ferreira
José Antonio Guimarāes Ferreira
The practice of reprocessing endoscopes and its effectiveness was evaluated in 37 services. Contamination of at least 1 endoscope could be identified in 34 (91.6%) of 37 services. Bacteria, fungi, and/or mycobacteria were isolated from 84.6% (33/39) of the colonoscopes (110–32,000 colony-forming units [CFUs]/mL) and from 80.6% (50/62) of the gastroscopes (100–33,000 CFUs/mL). Not all services followed recommended guidelines. Therefore, patients who underwent gastrointestinal endoscopies were exposed to diverse pathogens.

5 November 2019 in Infection Control & Hospital Epidemiology
Verified
Journal Article
Closed access
PDF file
MRMAÍRA MARQUES RIBEIRO
MAÍRA MARQUES RIBEIRO
KGKazuko U. Graziano
Kazuko U. Graziano
NONancy Olson
Nancy Olson
Rodrigo FrançaRodrigo França
Rodrigo França
MAMichelle J. Alfa
Michelle J. Alfa
Objective: To evaluate the efficacy of detergent and friction on removal of traditional biofilm and cyclic-buildup biofilm (CBB) from polytetrafluoroethylene (PTFE) channels and to evaluate the efficacy of glutaraldehyde to kill residual bacteria after cleaning. Methods: PTFE channels were exposed to artificial test soil containing 108 CFU/mL of Pseudomonas aeruginosa and Enterococcus faecalis, followed by full cleaning and high-level disinfection (HLD) for five repeated rounds to establish CBB. For traditional biofilm, the HLD step was omitted. Cleaning with enzymatic and alkaline detergents, bristle brush, and Pull Thru channel cleaner were compared to a water flush only. Carbohydrate, protein, viable count, adenosine triphosphate (ATP) levels were analyzed and atomic force microscopy (AFM) was performed. Results: In the absence of friction, cleaning of traditional biofilm and CBB was not effective compared to the positive control (Dunn-Bonferroni tests; P > .05) regardless of the detergent used. ATP, protein, and carbohydrate analyses were unable to detect traditional biofilm or CBB. The AFM analysis showed that fixation resulted in CBB being smoother and more compact than traditional biofilm. Conclusion: Friction during the cleaning process was a critical parameter regardless of the detergent used for removal of either traditional biofilm or CBB. Glutaraldehyde effectively killed the remaining microorganisms regardless of the cleaning method used.

9 December 2022 in Hygiene
Verified
Journal Article
Open access
PDF file
WRWilliam Martins Do rosario
William Martins Do rosario
TATais Villas Boas Pires de Almeida
Tais Villas Boas Pires de Almeida
BABélgica Andrade
Bélgica Andrade
IAIdalina Vieira Aoki
Idalina Vieira Aoki
BSBrunela Pereira da Silva
Brunela Pereira da Silva
KGKazuko Graziano
Kazuko Graziano
Corrosive surgical instruments are routinely observed in central sterile services departments around the world. In addition to other risks, they can harbor microorganisms in the form of biofilms. Thus, this study aimed to evaluate whether biofilms intentionally formed at corrosion points on surgical instruments are removable by manual and automated cleaning followed by sterilization. Laboratory experiments were performed where samples of corroded surgical instruments in use in practice were evaluated for biofilm presence using a scanning electron microscope. No biofilms were observed in the samples subjected to manual and automated cleaning, nor in the samples in which there was no intentional biofilm formation. Residual organic matter without the presence of microorganisms was observed.