Filippo Consolo

Dr. Filippo Consolo

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
DGDiego Gallo
Diego Gallo
DMDiana Massai
Diana Massai
FCFilippo Consolo
Filippo Consolo
RPRaffaele Ponzini
Raffaele Ponzini
ARAlberto Redaelli
Alberto Redaelli
Computational fluid dynamics (CFD) models have become very effective tools for predicting the flow field within the carotid bifurcation, and for understanding the relationship between local hemodynamics, and the initiation and progression of vascular wall pathologies. As prescribing proper boundary conditions can affect the solutions of the equations governing blood flow, in this study, we investigated the influence to assumptions regarding the outflow boundary conditions in an image-based CFD model of human carotid bifurcation. Four simulations were conducted with identical geometry, inlet flow rate, and fluid parameters. In the first case, a physiological time-varying flow rate partition at branches along the cardiac cycle was obtained by coupling the 3D model of the carotid bifurcation at outlets with a lumped-parameter model of the downstream vascular network. Results from the coupled model were compared with those obtained by imposing three fixed flow rate divisions (50/50, 60/40, and 70/30) between the two branches of the isolated 3D model of the carotid bifurcation. Three hemodynamic wall parameters were considered as indicators of vascular wall dysfunction. Our findings underscore that the overall effect of the assumptions done in order to simulate blood flow within the carotid bifurcation is mainly in the hot-spot modulation of the hemodynamic descriptors of atherosusceptible areas, rather than in their distribution. In particular, the more physiological, time-varying flow rate division deriving from the coupled simulation has the effect of damping wall shear stress (WSS) oscillations (differences among the coupled and the three fixed flow partition models are up to 37.3% for the oscillating shear index). In conclusion, we recommend to adopt more realistic constraints, for example, by coupling models at different scales, as in this study, when the objective is the outcome prediction of alternate therapeutic interventions for individual patients, or to test hypotheses related to the role of local fluid dynamics and other biomechanical factors in vascular diseases.

11 December 2013 in Stem Cells and Development
Verified
Journal Article
Closed access
SPStefano Pietronave
Stefano Pietronave
AZAndrea Zamperone
Andrea Zamperone
FOFrancesca Oltolina
Francesca Oltolina
Donato ColangeloDonato Colangelo
Donato Colangelo
Antonia FollenziAntonia Follenzi
Antonia Follenzi
MPMaria Prat
Maria Prat
Electrical stimulation (ES) of cells has been shown to induce a variety of responses, such as cytoskeleton rearrangements, migration, proliferation, and differentiation. In this study, we have investigated whether monophasic and biphasic pulsed ES could exert any effect on the proliferation and differentiation of human cardiac progenitor cells (hCPCs) isolated from human heart fragments. Cells were cultured under continuous exposure to monophasic or biphasic ES with fixed cycles for 1 or 3 days. Results indicate that neither stimulation protocol affected cell viability, while the cell shape became more elongated and reoriented more perpendicular to the electric field direction. Moreover, the biphasic ES clearly induced the upregulation of early cardiac transcription factors, MEF2D, GATA-4, and Nkx2.5, as well as the de novo expression of the late cardiac sarcomeric proteins, troponin T, cardiac alpha actinin, and SERCA 2a. Both treatments increased the expression of connexin 43 and its relocation to the cell membrane, but biphasic ES was faster and more effective. Finally, when hCPCs were exposed to both monophasic and biphasic ES, they expressed de novo the mRNA of the voltage-dependent calcium channel Cav 3.1(α 1G ) subunit, which is peculiar of the developing heart. Taken together, these results show that ES alone is able to set the conditions for early differentiation of adult hCPCs toward a cardiac phenotype.

10 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FCFilippo Consolo
Filippo Consolo
JSJawaad Sheriff
Jawaad Sheriff
SGSilvia Gorla
Silvia Gorla
NMNicolò Magri
Nicolò Magri
DBDanny Bluestein
Danny Bluestein
ARAlberto Redaelli
Alberto Redaelli
We systematically analyzed the relative contributions of frequency component elements of hemodynamic shear stress waveforms encountered in cardiovascular blood recirculating devices as to overall platelet activation over time. We demonstrated that high frequency oscillations are the major determinants for priming, triggering and yielding activated “prothrombotic behavior” for stimulated platelets, even if the imparted shear stress has low magnitude and brief exposure time. Conversely, the low frequency components of the stress signal, with limited oscillations over time, did not induce significant activation, despite being of high magnitude and/or exposure time. In vitro data were compared with numerical predictions computed according to a recently proposed numerical model of shear-mediated platelet activation. The numerical model effectively resolved the correlation between platelet activation and the various frequency components examined. However, numerical predictions exhibited a different activation trend compared to experimental results for different time points of a stress activation sequence. With this study we provide a more fundamental understanding for the mechanobiological responsiveness of circulating platelets to the hemodynamic environment of cardiovascular devices, and the importance of these environments in mediating life-threatening thromboembolic complications associated with shear-mediated platelet activation. Experimental data will guide further optimization of the thromboresistance of cardiovascular implantable therapeutic devices.

21 May 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Maria Cristina VinciMaria Cristina Vinci
Maria Cristina Vinci
GTGiulio Tessitore
Giulio Tessitore
LCLaura Castiglioni
Laura Castiglioni
FPFrancesca Prandi
Francesca Prandi
Monica SonciniMonica Soncini
Monica Soncini
Maurizio PesceMaurizio Pesce
Maurizio Pesce
The pericardial tissue is commonly used to produce bio-prosthetic cardiac valves and patches in cardiac surgery. The procedures adopted to prepare this tissue consist in treatment with aldehydes, which do not prevent post-graft tissue calcification due to incomplete xeno-antigens removal. The adoption of fixative-free decellularization protocols has been therefore suggested to overcome this limitation. Although promising, the decellularized pericardium has not yet used in clinics, due to the absence of proofs indicating that the decellularization and cryopreservation procedures can effectively preserve the mechanical properties and the immunologic compatibility of the tissue. The aim of the present work was to validate a procedure to prepare decellularized/cryopreserved human pericardium which may be implemented into cardiovascular homograft tissue Banks. The method employed to decellularize the tissue completely removed the cells without affecting ECM structure; furthermore, uniaxial tensile loading tests revealed an equivalent resistance of the decellularized tissue to strain, before and after the cryopreservation, in comparison with the fresh tissue. Finally, immunological compatibility, showed a minimized host immune cells invasion and low levels of systemic inflammation, as assessed by tissue transplantation into immune-competent mice. Our results indicate, for the first time, that fixative-free decellularized pericardium from cadaveric tissue donors can be banked according to Tissue Repository-approved procedures without compromising its mechanical properties and immunological tolerance. This tissue can be therefore treated as a safe homograft for cardiac surgery.

28 December 2017 in European Journal of Heart Failure
Verified
Journal Article
Closed access
PDF file
FCFilippo Consolo
Filippo Consolo
GSGiulia Sferrazza
Giulia Sferrazza
GMGiulia Motolone
Giulia Motolone
RCRachele Contri
Rachele Contri
LVLorenzo Valerio
Lorenzo Valerio
FPFederico Pappalardo
Federico Pappalardo

15 October 2020 in ASAIO Journal
Verified
Journal Article
Closed access
ABAndrea Boraschi
Andrea Boraschi
SBSilvia Bozzi
Silvia Bozzi
BTBente Thamsen
Bente Thamsen
Marcus GraneggerMarcus Granegger
Marcus Granegger
LWLena Wiegmann
Lena Wiegmann
FCFilippo Consolo
Filippo Consolo
Contemporary centrifugal continuous-flow left ventricular assist devices (LVADs) incorporate dynamic speed modulation algorithms. Hemocompatibility of these periodic unsteady pump operating conditions has been only partially explored. We evaluated whether speed modulation induces flow alterations associated with detrimental prothrombotic effects. For this aim, we evaluated the thrombogenic profile of the HeartWare ventricular assist device (HVAD) Lavare Cycle (LC) and HeartMate3 (HM3) artificial pulse (AP) via comprehensive numerical evaluation of (i) pump washout, (ii) stagnation zones, (iii) shear stress regimens, and (iv) modeling of platelet activation status via the platelet activity state (PAS) model. Data were compared between different simulated operating scenarios, including: (i) constant rotational speed and pump pressure head, used as reference; (ii) unsteady pump pressure head as induced by cardiac pulsatility; and (iii) unsteady rotor speed modulation of the LC (HVAD) and AP (HM3). Our results show that pump washout did not improve across the different simulated scenarios in neither the HVAD nor the HM3. The LC reduced but did not eliminate flow stagnation (–57%) and did not impact metrics of HVAD platelet activation (median PAS: +0.4%). The AP reduced HM3 flow stagnation by up to 91% but increased prothrombotic shear stress and simulated platelet activation (median PAS: +124%). Our study advances understanding of the pathogenesis of LVAD thrombosis, suggesting mechanistic implications of rotor speed modulation. Our data provide rationale criteria for the future design optimization of next generation LVADs to further reduce hemocompatibility-related adverse events.