Fabiana Danieli

Dr. Fabiana Danieli

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2016 in International Archives of Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
RBRicardo Ferreira Bento
Ricardo Ferreira Bento
FDFabiana Danieli
Fabiana Danieli
AMAna Tereza de Matos Magalhães
Ana Tereza de Matos Magalhães
DGDan Gnansia
Dan Gnansia
MHMichel Hoen
Michel Hoen
Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting soft-surgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 +/− 16.1 dB HL up to 500 Hz and 15.7 +/− 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.

1 June 2011 in Audiology - Communication Research
Verified
Journal Article
Open access
PDF file
FDFabiana Danieli
Fabiana Danieli
ECEliane Aparecida Techi Castiquini
Eliane Aparecida Techi Castiquini
TZTiciana Cristina de Freitas Zambonatto
Ticiana Cristina de Freitas Zambonatto
MBMaria Cecília Bevilacqua
Maria Cecília Bevilacqua
OBJETIVO: Adaptar culturalmente o questionário Satisfaction with Amplification in Daily Life (SADL), versão em Português Brasileiro, para administrar em usuários de aparelhos de amplificação sonora individuais (AASIs) dispensados pelo Sistema Único de Saúde (SUS). MÉTODOS: Participaram da pesquisa 19 sujeitos usuários de AASIs dispensados pelo Sistema Único de Saúde, por no mínimo três semanas, com idade igual ou superior a 60 anos, que apresentavam perda auditiva pós-lingual, sendo 63% do gênero masculino e 37% do gênero feminino, com média de idade de 73 anos e média de tempo de uso das próteses auditivas de cinco meses. Os sujeitos responderam ao questionário SADL e a uma Escala de Satisfação de item único, além de alguns itens adicionais. Foi realizada a análise da consistência interna do SADL, a análise descritiva dos resultados, para caracterizar as respostas dos sujeitos, a comparação dos resultados com os dados normativos propostos pelos autores e uma investigação do relacionamento entre o SADL e a escala de satisfação de item único. RESULTADOS: Os resultados obtidos para a pontuação global evidenciaram que os sujeitos, em média, encontravam-se satisfeitos com seus AASIs. O mesmo ocorreu para todas as subescalas do SADL, sendo que a subescala Imagem Pessoal apresentou o maior número de pessoas muito satisfeitas. Os resultados obtidos foram equivalentes aos encontrados pelos autores e o SADL mostrou ser um questionário com boa consistência interna (0,71). Houve íntima relação entre a escala de satisfação de item único e a pontuação global do SADL. Para as duas medidas de satisfação, a maioria dos sujeitos demonstrou estar "satisfeito" com seus AASIs e ambas as escalas apresentaram correlação alta e significativa (0,935). CONCLUSÃO: Em média, os sujeitos estavam satisfeitos com seus AASIs dispensados pelo SUS. O questionário SADL, versão em Português Brasileiro, mostrou-se um instrumento eficaz para avaliar o nível de satisfação dos usuários de AASIs dispensados pelo SUS avaliados neste estudo. Novas pesquisas são necessárias para complementar estes achados.

25 June 2020 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
FDFabiana Danieli
Fabiana Danieli
TDThomas Dermacy
Thomas Dermacy
MAMaria Stella Arantes Do Amaral
Maria Stella Arantes Do Amaral
ARAna Cláudia Mirandola Barbosa Reis
Ana Cláudia Mirandola Barbosa Reis
DGDan Gnansia
Dan Gnansia
MHMiguel Angelo Hyppolito
Miguel Angelo Hyppolito

20 October 2015 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
GCGuilherme Machado de Carvalho
Guilherme Machado de Carvalho
AGAlexandre Caixeta Guimarães
Alexandre Caixeta Guimarães
FDFabiana Danieli
Fabiana Danieli
LOLúcia Cristina Beltrame Onuki
Lúcia Cristina Beltrame Onuki
JPJorge Rizzato Paschoal
Jorge Rizzato Paschoal
ACArthur Menino Castilho
Arthur Menino Castilho
Cochlear implants have revolutionized the way patients affected by severe hearing loss experience the world. Neurelec developed a fixation system with two titanium screws that requires no skull bone drilling. To describe the outcomes and procedure-related details of a series of patients implanted with the Digisonic® SP cochlear implant. This retrospective study analyzed patients submitted to cochlear implant placement within a period of 18 months. All patients had postlingual hearing impairment. Data was collected from patient charts and standard questionnaires answered by the surgeons in charge of carrying out the procedures. The six patients offered the Digisonic® SP cochlear implants were operated by experienced surgeons. The procedures took 95 to 203 minutes (mean = 135') to be completed, which is less time than what has been described for other fixation approaches. No complications were recorded and hearing improvement was satisfactory. The Digisonic® SP cochlear implant developed by Neurelec offered good audiological results for adult patients, shorter surgery time, and no surgical or postoperative complications.

1 March 2013 in Audiology - Communication Research
Verified
Journal Article
Open access
PDF file
FDFabiana Danieli
Fabiana Danieli
MBMaria Cecília Bevilacqua
Maria Cecília Bevilacqua
OBJETIVO: Estudar comparativamente a habilidade de reconhecimento de fala no silêncio e na presença de ruído competitivo em crianças usuárias de implante coclear utilizando dois diferentes processadores de fala. MÉTODOS: Foram avaliadas 26 crianças usuárias do implante coclear Nucleus 24M/24K, da Cochlear Corporation®, divididas em dois grupos de acordo com o processador de fala utilizado. O Grupo 1 foi composto por 16 crianças que faziam uso do processador de fala Sprint e o Grupo 2 foi composto por 10 crianças que faziam uso do processador de fala Freedom. Foi aplicado o Hearing in Noise Test - versão em Português/Brasil, em campo livre, na condição de silêncio e na presença de ruído competitivo. RESULTADOS: O desempenho do Grupo 2 (Freedom) foi superior ao desempenho do Grupo 1 (Sprint) em todas as condições de avaliação, sendo evidenciada diferença entre eles na condição de silêncio. CONCLUSÃO: O processador de fala apresentou influência significativa na percepção de fala de crianças usuárias dos implantes cocleares Nucleus 24K e 24M. As características de pré-processamento do som presentes no processador de fala Freedom podem ter contribuído para o melhor desempenho do Grupo 2 nos testes de percepção de fala realizados. Novos estudos são necessários para complementação destes achados.

30 December 2022 in Cochlear Implants International
Verified
Journal Article
Closed access
MHMiguel Hyppolito
Miguel Hyppolito
ARAna Cláudia Mirândola Barbosa Reis
Ana Cláudia Mirândola Barbosa Reis
FDFabiana Danieli
Fabiana Danieli
RHRaabid Hussain
Raabid Hussain
NGNicolas Le Goff
Nicolas Le Goff
Objectives: To investigate the outcomes of cochlear re-implantation using multi-mode grounding stimulation associated with anodic monophasic pulses to manage abnormal facial nerve stimulation (AFNS) in cochlear implant (CI) recipients. Methods: Retrospective case report. An adult CI recipient with severe AFNS and decrease in auditory performance was re-implanted with a new CI device to change the pulse shape and stimulation mode. Patient’s speech perception scores and AFNS were compared before and after cochlear re-implantation, using monopolar stimulation associated with cathodic biphasic pulses and multi-mode stimulation mode associated to anodic monophasic pulses, respectively. The insertion depth angle and the electrode-nerve distances were also investigated, before and after cochlear re-implantation. Results: AFNS was resolved, and the speech recognition scores rapidly increased in the first year after cochlear re-implantation while remaining stable. After cochlear re-implantation, the e15 and e20 electrodes showed shorter electrode-nerve distances compared to their correspondent e4 and e7 electrodes, which induced AFNS in the first implantation. Conclusions: Cochlear re-implantation with multi-mode grounding stimulation associated with anodic monophasic pulses was an effective strategy for managing AFNS. The patient’s speech perception scores rapidly improved and AFNS was not detected four years after cochlear re-implantation.