Muhannad Alkassar

Dr. Muhannad Alkassar

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
PGPia Gehrsitz
Pia Gehrsitz
OROliver Rompel
Oliver Rompel
MSMartin Schöber
Martin Schöber
RCRobert Cesnjevar
Robert Cesnjevar
APAriawan Purbojo
Ariawan Purbojo
MAMuhannad Alkassar
Muhannad Alkassar
Cinematic rendering (CR) is based on a new algorithm that creates a photo-realistic three-dimensional (3D) picture from cross-sectional images. Previous studies have shown its positive impact on preoperative planning. To date, CR presentation has only been possible on 2D screens which limited natural 3D perception. To depict CR-hearts spatially, we used mixed-reality technology and mapped corresponding hearts as holograms in 3D space. Our aim was to assess the benefits of CR-holograms in the preoperative planning of cardiac surgery. Including 3D prints allowed a direct comparison of two spatially resolved display methods. Twenty-six patients were recruited between February and September 2019. CT or MRI was used to visualize the patient's heart preoperatively. The surgeon was shown the anatomy in cross-sections on a 2D screen, followed by spatial representations as a 3D print and as a high-resolution hologram. The holographic representation was carried out using mixed-reality glasses (HoloLens®). To create the 3D prints, corresponding structures were segmented to create STL files which were printed out of resin. In 22 questions, divided in 5 categories (3D-imaging effect, representation of pathology, structure resolution, cost/benefit ratio, influence on surgery), the surgeons compared each spatial representation with the 2D method, using a five-level Likert scale. The surgical preparation time was assessed by comparing retrospectively matched patient pairs, using a paired t-test. CR-holograms surpassed 2D-monitor imaging in all categories. CR-holograms were superior to 3D prints in all categories (mean Likert scale 4.4 ± 1.0 vs. 3.7 ± 1.3, P < 0.05). Compared to 3D prints it especially improved the depth perception (4.7 ± 0.7 vs. 3.7 ± 1.2) and the representation of the pathology (4.4 ± 0.9 vs. 3.6 ± 1.2). 3D imaging reduced the intraoperative preparation time (n = 24, 59 ± 23 min vs. 73 ± 43 min, P < 0.05). In conclusion, the combination of an extremely photo-realistic presentation via cinematic rendering and the spatial presentation in 3D space via mixed-reality technology allows a previously unattained level of comprehension of anatomy and pathology in preoperative planning.

1 July 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DMDenisa Martonová
Denisa Martonová
MAMuhannad Alkassar
Muhannad Alkassar
JSJulia Seufert
Julia Seufert
DHDavid Holz
David Holz
MDMinh Tuấn Dương
Minh Tuấn Dương
SLSigrid Leyendecker
Sigrid Leyendecker

18 January 2021 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
PDF file
DFDominik J. Fiegle
Dominik J. Fiegle
MSMartin Schöber
Martin Schöber
SDSven Dittrich
Sven Dittrich
RCRobert Cesnjevar
Robert Cesnjevar
KKKarin Klingel
Karin Klingel
TSThomas Seidel
Thomas Seidel
Chronic heart failure (HF) in adults causes remodeling of the cardiomyocyte transverse tubular system (t-system), which contributes to disease progression by impairing excitation-contraction (EC) coupling. However, it is unknown if t-system remodeling occurs in pediatric heart failure. This study investigated the t-system in pediatric viral myocarditis. The t-system and integrity of EC coupling junctions (co-localization of L-type Ca2+ channels with ryanodine receptors and junctophilin-2) were analyzed by 3D confocal microscopy in left-ventricular (LV) samples from 5 children with myocarditis (age 14 ± 3 months), undergoing ventricular assist device (VAD) implantation, and 5 children with atrioventricular septum defect (AVSD, age 17 ± 3 months), undergoing corrective surgery. LV ejection fraction (EF) was 58.4 ± 2.3% in AVSD and 12.2 ± 2.4% in acute myocarditis. Cardiomyocytes from myocarditis samples showed increased t-tubule distance (1.27 ± 0.05 μm, n = 34 cells) and dilation of t-tubules (volume-length ratio: 0.64 ± 0.02 μm2) when compared with AVSD (0.90 ± 0.02 μm, p < 0.001; 0.52 ± 0.02 μm2, n = 61, p < 0.01). Intriguingly, 4 out of 5 myocarditis samples exhibited sheet-like t-tubules (t-sheets), a characteristic feature of adult chronic heart failure. The fraction of extracellular matrix was slightly higher in myocarditis (26.6 ± 1.4%) than in AVSD samples (24.4 ± 0.8%, p < 0.05). In one case of myocarditis, a second biopsy was taken and analyzed at VAD explantation after extensive cardiac recovery (EF from 7 to 56%) and clinical remission. When compared with pre-VAD, t-tubule distance and density were unchanged, as well as volume-length ratio (0.67 ± 0.04 μm2 vs. 0.72 ± 0.05 μm2, p = 0.5), reflecting extant t-sheets. However, junctophilin-2 cluster density was considerably higher (0.12 ± 0.02 μm−3 vs. 0.05 ± 0.01 μm−3, n = 9/10, p < 0.001), approaching values of AVSD (0.13 ± 0.05 μm−3, n = 56), and the measure of intact EC coupling junctions showed a distinct increase (20.2 ± 5.0% vs. 6.8 ± 2.2%, p < 0.001). Severe t-system loss and remodeling to t-sheets can occur in acute HF in young children, resembling the structural changes of chronically failing adult hearts. T-system remodeling might contribute to cardiac dysfunction in viral myocarditis. Although t-system recovery remains elusive, recovery of EC coupling junctions may be possible and deserves further investigation.

11 October 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
DHDavid Holz
David Holz
MDMinh Tuấn Du'O'NG
Minh Tuấn Du'O'NG
DMDenisa Martonová
Denisa Martonová
MAMuhannad Alkassar
Muhannad Alkassar
SLSigrid Leyendecker
Sigrid Leyendecker
In the past decades, the structure of the heart, human as well as other species, has been explored in a detailed way, e.g., via histological studies or diffusion tensor magnetic resonance imaging. Nevertheless, the assignment of the characteristic orthotropic structure in a patient-specific finite element model remains a challenging task. Various types of rule-based models, which define the local fiber and sheet orientation depending on the transmural depth, have been developed. However, the correct assessment of the transmural depth is not trivial. Its accuracy has a substantial influence on the overall mechanical and electrical properties in rule-based models. The main purpose of this study is the development of a finite element-based approach to accurately determine the transmural depth on a general unstructured grid. Instead of directly using the solution of the Laplace problem as the transmural depth, we make use of a well-established model for the assessment of the transmural thickness. It is based on two hyperbolic first-order partial differential equations for the definition of a transmural path, whereby the transmural thickness is defined as the arc length of this path. Subsequently, the transmural depth is determined based on the position on the transmural path. Originally, the partial differential equations were solved via finite differences on structured grids. In order to circumvent the need of two grids and mapping between the structured (to determine the transmural depth) and unstructured (electromechanical heart simulation) grids, we solve the equations directly on the same unstructured tetrahedral mesh. We propose a finite-element-based discontinuous Galerkin approach. Based on the accurate transmural depth, we assign the local material orientation of the orthotropic tissue structure in a usual fashion. We show that this approach leads to a more accurate definition of the transmural depth. Furthermore, for the left ventricle, we propose functions for the transmural fiber and sheet orientation by fitting them to literature-based diffusion tensor magnetic resonance imaging data. The proposed functions provide a distinct improvement compared to existing rules from the literature.

10 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMuhannad Alkassar
Muhannad Alkassar
SESophia Engelhardt
Sophia Engelhardt
TATariq Abu-Tair
Tariq Abu-Tair
EOEfrén Ojeda
Efrén Ojeda
PTPhilipp C. Treffer
Philipp C. Treffer
OROliver Rompel
Oliver Rompel
This study investigates the crucial factors influencing the end-systolic and end-diastolic volumes in MRI volumetry and their direct effects on the derived functional parameters. Through the simultaneous acquisition of 2D-cine and 3D whole-heart slices in end-diastole and end-systole, we present a novel direct comparison of the volumetric measurements from both methods. A prospective study was conducted with 18 healthy participants. Both 2D-cine and 3D whole-heart sequences were obtained. Despite the differences in the creation of 3D volumes and trigger points, the impact on the LV volume was minimal (134.9 mL ± 16.9 mL vs. 136.6 mL ± 16.6 mL, p < 0.01 for end-diastole; 50.6 mL ± 11.0 mL vs. 51.6 mL ± 11.2 mL, p = 0.03 for end-systole). In our healthy patient cohort, a systematic underestimation of the end-systolic volume resulted in a significant overestimation of the SV (5.6 mL ± 2.6 mL, p < 0.01). The functional calculations from the 3D whole-heart method proved to be highly accurate and correlated well with function measurements from the phase-contrast sequences. Our study is the first to demonstrate the superiority of 3D whole-heart volumetry over 2D-cine volumetry and sheds light on the systematic error inherent in 2D-cine measurements.

23 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
TATariq Abu-Tair
Tariq Abu-Tair
STSalmai Turial
Salmai Turial
IWInes Willershausen
Ines Willershausen
MAMuhannad Alkassar
Muhannad Alkassar
GSGundula Staatz
Gundula Staatz
CKChristoph Kampmann
Christoph Kampmann
Background: The severity of pectus excavatum is classified by the Haller Index (HI) and/or Correction Index (CI). These indices measure only the depth of the defect and, therefore, impede a precise estimation of the actual cardiopulmonary impairment. We aimed to evaluate the MRI-derived cardiac lateralization to improve the estimation of cardiopulmonary impairment in Pectus excavatum in connection with the Haller and Correction Indices. Methods: This retrospective cohort study included a total of 113 patients (mean age = 19.03 ± 7.8) with pectus excavatum, whose diagnosis was verified on cross-sectional MRI images using the HI and CI. For the development of an improved HI and CI index, the patients underwent cardiopulmonary exercise testing to assess the influence of the right ventricle’s position on cardiopulmonary impairment. The indexed lateral position of the pulmonary valve was utilized as a surrogate parameter for right ventricle localization. Results: In patients with PE, the heart’s lateralization significantly correlated with the severity of pectus excavatum (p ≤ 0.001). When modifying HI and CI for the individual’s pulmonary valve position, those indices are present with greater sensitivity and specificity regarding the maximum oxygen-pulse as a pathophysiological correlate of reduced cardiac function (χ2 10.986 and 15.862, respectively). Conclusion: The indexed lateral deviation of the pulmonary valve seems to be a valuable cofactor for HI and CI, allowing for an improved description of cardiopulmonary impairment in PE patients.