Minh Tuan Duong

Minh Tuan Duong

Auto-generated profile, based on publicly available information

Minh Tuan Duong

Institute of Applied Dynamics (LTD), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen 91054, Bavaria, Germany; School of Mechanical Engineering, Hanoi University of Science and Technology, Ha Noi, Viet Nam

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DMDenisa Martonová
Denisa Martonová
MAMuhannad Alkassar
Muhannad Alkassar
JSJulia Seufert
Julia Seufert
DHDavid Holz
David Holz
MDMinh Tuấn Dương
Minh Tuấn Dương
SLSigrid Leyendecker
Sigrid Leyendecker

1 September 2012 in Journal of Biomechanics
Verified
Journal Article
Closed access
NNN. Huynh Nguyễn
N. Huynh Nguyễn
MDM. Tuấn Dương
M. Tuấn Dương
TTT. Ngọc Trần
T. Ngọc Trần
PPP. Tình Phạm
P. Tình Phạm
OGOliver Grottke
Oliver Grottke
Manfred StaatManfred Staat
Manfred Staat

1 January 2015 in International Biomechanics
Verified
Journal Article
Open access
MDM. Tuấn Dương
M. Tuấn Dương
NNN. Huynh Nguyễn
N. Huynh Nguyễn
TTT. Ngọc Trần
T. Ngọc Trần
RTR.H. Tolba
R.H. Tolba
Manfred StaatManfred Staat
Manfred Staat
Preservation conditions may affect internal organs thus influencing the results of protracted biomechanical tests. The influence of the freeze–thaw cycle on the mechanical behaviour of porcine abdominal organs was reported in our previous work. Here we further investigate the effects of refrigerated storage on the mechanical properties of porcine spleen and liver. Twenty-seven swine were chosen for tensile testing. To simulate the conservation conditions before biomechanical experimentation, the total sample was divided into three groups of nine individuals each and tested in a fresh state, after a freeze–thaw cycle, and after refrigerated storage (+4 °C). Fitted stress–stretch curves for each tissue type were obtained by employing a modified Fung model for isotropic behaviour. The results suggest statistically significant effects of refrigerated storage on the spleen but negligible influence on the liver. Similarly to the impact of the freeze–thaw cycle, refrigerated storage caused a decrease in the mechanical properties of the spleen. This again supports the hypothesized cause of the altered behaviour of spleen due to the autolysis of elastin by elastolytic enzymes during and after the cooling period. Spleen and liver are good examples of tissue with and without elastin. These findings have wide biomechanical and decomposition implications for the study of soft tissues.

1 October 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AHAndreas Horbach
Andreas Horbach
MDMinh Tuan Duong
Minh Tuan Duong
Manfred StaatManfred Staat
Manfred Staat

24 September 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
MDMinh Tuấn Du'O'NG
Minh Tuấn Du'O'NG
DHDavid Holz
David Holz
MAMuhannad Alkassar
Muhannad Alkassar
SDSven Dittrich
Sven Dittrich
SLSigrid Leyendecker
Sigrid Leyendecker
In this paper, we are investigating the interaction between different passive material models and the mechano-electrical feedback (MEF) in cardiac modeling. Various types of passive mechanical laws (nearly incompressible/compressible, polynomial/exponential-type, transversally isotropic/orthotropic material models) are integrated in a fully coupled electromechanical model in order to study their specific influence on the overall MEF behavior. Our computational model is based on a three-dimensional (3D) geometry of a healthy rat left ventricle reconstructed from magnetic resonance imaging (MRI). The electromechanically coupled problem is solved using a fully implicit finite element-based approach. The effects of different passive material models on the MEF are studied with the help of numerical examples. It turns out that there is a significant difference between the behavior of the MEF for compressible and incompressible material models. Numerical results for the incompressible models exhibit that a change in the electrophysiology can be observed such that the transmembrane potential (TP) is unable to reach the resting state in the repolarization phase, and this leads to non-zero relaxation deformations. The most significant and strongest effects of the MEF on the rat cardiac muscle response are observed for the exponential passive material law.

8 December 2015 in Asia Pacific Journal on Computational Engineering
Verified
Journal Article
Open access
PDF file
MDMinh Tuan Duong
Minh Tuan Duong
NNNhu Huynh Nguyen
Nhu Huynh Nguyen
Manfred StaatManfred Staat
Manfred Staat
A hyperelastic model must not only characterize the mechanical response of a composite material such as soft tissue, but also ensure numerical stability by a feasible set of material parameters. Apart from the well-known ill-conditioning problem caused by the incompressibility constraint, the paper indicates another ill-conditioning occurring in any general fibre-reinforced material model for tubular organs when unbalance between the fibre strain energy and the matrix strain energy becomes too large. Specifically, although the Holzapfel model is polyconvex, this problem can be observed as an unphysical behaviour in a physiological deformation range of a tissue such as arterial wall and intestine by thickening in the thickness direction associated with a volume growth of a specimen in a tension test. Particularly, the same problem for a polyconvex modified Fung-type model with the matrix characterized by the neo-Hookean model has been discussed for the first time. By investigating the influence of the shear modulus in these two models, we not only prove the cause of the ill-conditioning but also propose a solution to control the unbalance in the strain energy. The numerical results show significant enhancement of the model stability in overcoming the unphysical deformation.