Guillaume Debellemanière

Dr. Guillaume Debellemanière

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
Damien GatinelDamien Gatinel
Damien Gatinel
GDGuillaume Debellemanière
Guillaume Debellemanière
ASAlain Saad
Alain Saad
RRRadhika Rampat
Radhika Rampat
AWAvi Wallerstein
Avi Wallerstein
JMJacques Malet
Jacques Malet
To provide a simplified method to optimize lens constants to zero the mean prediction error (ME) of an intraocular lens (IOL) calculation formula, without the need to program the formula itself, by exploring the influence of IOL and corneal power on the refractive impact of variations in effective lens position. Theoretical development of an optimized formula and retrospective clinical evaluation on documented datasets. Retrospective data from 8878 patients with cataracts with pre- and postoperative measurements available using 4 IOL models and 6 IOL power calculation formulas were examined. A schematic eye model was used to study the impact of small variations in effective lens position (ELP) on the postoperative spherical equivalent (SE) refraction. The impact of keratometry (K) and IOL power (P) on SE was investigated. A theoretical thick lens model was used to devise a formula to zero the average prediction error of an IOL power calculation formula. This was achieved by incrementing the predicted ELP, which could then be translated into an increment in the IOL constant. This method was tested on documented real-life postoperative datasets, using different IOL models and single-constant optimized IOL calculation formulas. For small variations in ELP, there was an exponential relationship between IOL power and the resultant postoperative refractive variation. The ELP adjustment necessary to zero the ME equated to a ratio between the ME and the mean of the following expression: 0.0006*(P2+2K*P) on the considered datasets. The accuracy of the values obtained using this formula was confirmed on documented postoperative datasets, and on published and nonpublished formulas. The proposed method allows surgeons without special expertise to optimize an IOL constant to nullify the ME on a documented dataset without coding the different formulas. The influence of individual eyes is proportional to the squared power of the implanted IOL.

19 October 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
GDGuillaume Debellemanière
Guillaume Debellemanière
NMNicole Mechleb
Nicole Mechleb
TBTimothée Bernier
Timothée Bernier
JAJean-Marc Ancel
Jean-Marc Ancel
MGMathieu Gauvin
Mathieu Gauvin
Damien GatinelDamien Gatinel
Damien Gatinel
To describe the development of the post-myopic laser vision correction (LVC) version of the PEARL-DGS intraocular lens (IOL) calculation formula and to evaluate its outcomes on an independent test set. Retrospective, single-center case series. A modified lens position prediction algorithm was designed along with methods to predict the posterior corneal curvature radius and correct the corneal power measurement error. A different set of previously operated eyes that underwent LVC was used to evaluate the prediction precision of the post-LVC formula. Post-LVC PEARL-DGS formula significantly reduced mean absolute error of prediction in comparison to Haigis-L, Shammas, and American Society of Cataract and Refractive Surgery (ASCRS) average formulas (P < .001). It exhibited similar postoperative refractive precision as the Barrett True-K No History formula (P = .61). The post-LVC formula development process described in this article performed as well as the state-of-the-art post-LVC formula on the present test set. Further studies are required to assess its efficacy in other independent sets.

1 November 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
ASAlain Saad
Alain Saad
GDGuillaume Debellemanière
Guillaume Debellemanière
PZPierre Zéboulon
Pierre Zéboulon
MRMaria Rizk
Maria Rizk
HRHélène Od Rouger
Hélène Od Rouger
Damien GatinelDamien Gatinel
Damien Gatinel
Purpose: To combine objective machine-derived corneal parameters obtained with new swept-source optical coherence tomography (SS-OCT) tomographer (Anterion) to differentiate between normal (N), keratoconus (KC) and forme fruste KC (FFKC). Setting: Laser Center, Hôpital Fondation Adolphe de Rothschild, Paris, France. Design: Retrospective study. Methods: 281 eyes of 281 patients were included and divided into 3 groups: N (n = 156), FFKC (n = 43), and KC (n = 82). Eyes were included in each group based on objective evaluation using Nidek Corneal Navigator, and subjective evaluation by authors. The SS-OCT system provided anterior and posterior corneal surface and pachymetry derived variables. The training set was composed of 143 eyes (95 N, 43 FFKC). Discriminant analysis was used to determine the group of an observation based on a set of variables. The obtained formula was tested in the validation set composed of 61 N and 82 KC. Results: Among curvature parameters, the FFKC had significantly higher irregularity index at 3 mm and 5 mm, higher inferior-superior index, higher SteepK-OppositeK index and inferiorly decentered posterior steepest keratometry. Among thickness parameters: central pachymetry, thinnest pachymetry, percentage of thickness increase from center to periphery, and inferior decentration of the thinnest point were statistically different between groups. Combination of multiple variables into a discriminant function (F1) included 5 parameters and reached an area under the receiver operating characteristic curve (AUROC) of 0.95 (sensitivity = 75%, specificity = 98.5%) for detection of FFKC. F1 differentiates N from KC with AUROC = 0.99 (sensitivity = 99%, specificity = 99%). Conclusions: Combining anterior and posterior curvatures variables along with pachymetric data obtained from SS-OCT allowed automated detection of early KC and KC with very good accuracy (87% and 99.5% respectively).

23 September 2022 in Cornea
Verified
Journal Article
Open access
GDGuillaume Debellemanière
Guillaume Debellemanière
WGWassim Ghazal
Wassim Ghazal
MDMathieu Dubois
Mathieu Dubois
RRRadhika Rampat
Radhika Rampat
LFLaura Fabre
Laura Fabre
Damien GatinelDamien Gatinel
Damien Gatinel
Purpose: The aim of this study was to determine the mechanisms leading to the refractive shift and intraocular lens calculation error induced by Descemet membrane endothelial keratoplasty (DMEK), using ocular biometry and corneal elevation tomography data. Methods: This is a retrospective, monocentric cohort study. Eyes which underwent uncomplicated DMEK surgery with available pre-DMEK and post-DMEK Scheimpflug rotating camera data (Pentacam, Oculus, Wetzlar, Germany) were considered for inclusion with an age-matched control group of healthy corneas. Cataract surgery data were collected for triple-DMEK cases. DMEK-induced refractive shift (DIRS) and intraocular lens calculation error (DICE) were calculated. Pearson r correlation coefficient was calculated between each corneal parameter variation and both DIRS and DICE. Results: DIRS was calculable for 49 eyes from 43 patients. It was 30.61% neutral, 53.06% hyperopic (36.73% > 1D), and 16.32% myopic (6.12% > 1 D). DICE was calculable for 30 eyes of 26 patients: It was 46.67% neutral, 40.00% hyperopic (10.00% > 1D), and 13.33% myopic (3.33% > 1D). DIRS and DICE were mainly associated with variations in PRC/ARC ratio, anterior average radii of curvature (ARC), posterior average radii of curvature (PRC), and posterior Q. Conclusions: Our results suggest that ARC variations, PRC/ARC ratio variations, PRC variations, and posterior Q variations are the most influential parameters for both DIRS and DICE. We suggest that a distinction between those different phenomenons, both currently described as “hyperopic shift” in the literature, should be made by researchers and clinicians.

Verified
Journal Article
Open access
PDF file
Damien GatinelDamien Gatinel
Damien Gatinel
GDGuillaume Debellemanière
Guillaume Debellemanière
ASAlain Saad
Alain Saad
RRRadhika Rampat
Radhika Rampat
JMJacques Malet
Jacques Malet
To ascertain the theoretical impact of optical design variations of the intraocular lens (IOL) on the accuracy of IOL power formulas based on a single lens constant using a thick lens eye model. This impact was also simulated before and after optimization. We modeled 70 thick-lens pseudophakic eyes implanted with IOLs of symmetrical optical design and power comprised between 0.50 D and 35 D in 0.5-step increments. Modifications of the shape factor resulting in variations in the anterior and posterior radii of an IOL were made, keeping the central thickness and paraxial powers static. Geometry data from three IOL models were also used. Corresponding postoperative spherical equivalent (SE) were computed for different IOL powers and assimilated to a prediction error of the formula due to the sole change in optical design alone. Formula accuracy was studied before and after zeroization on a uniform and non-uniform realistic IOL power distribution. The impact of the incremental change in optic design variability depended on the IOL power. Design modifications theoretically induce an increase in the standard deviation (SD), Mean Absolute Error (MAE), and Root Mean Square (RMS) of the error. The values of these parameters reduce dramatically after zeroization. While the variations in optical design can affect refractive outcomes, especially in short eyes, the zeroization of the mean error theoretically reduces the impact of the IOL’s design and power on the accuracy of IOL power calculation.

1 December 2020 in American Journal of Ophthalmology Case Reports
Verified
Journal Article
Open access
CPChristophe Panthier
Christophe Panthier
MBMagalie Bouvet
Magalie Bouvet
GDGuillaume Debellemanière
Guillaume Debellemanière
DGDamien Gatinel
Damien Gatinel
The most common cause of severe limbal stem cell deficiency (LSCD) is chemical injury. We report a case of severe unilateral alkali injury complicated by total LSCD, treated with customized Simple limbal epithelial transplantation (SLET) combined with conjunctival-limbal autografting (CLAU). A 23-year-old female sustained a severe unilateral alkali chemical injury, resulting in total LSCD, treated with customized SLET combined with CLAU. We used two autologous limbal biopsies harvested from the fellow eye. One was used for CLAU and the second was split into multiple pieces, and was glued to bare stroma following resection of the corneal pannus. A stable ocular surface was achieved, and the donor eye remained healthy. Visual acuity improved from hand motion initially, to 20/20 over one year post-operatively. This case report demonstrates the efficacy and safety of customized SLET with supplemental CLAU to treat total LSCD in severe ocular burns.