Angelina Stoyanova-Ivanova

Dr. Angelina Stoyanova-Ivanova

SOFT MATTER PHYSICS, G. Nadjakov Institute of Solid State Physics - Bulgarian Academy of Sciences, Sofia, Sofia-Grad, Bulgaria
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2021 in Membranes
Verified
Journal Article
Open access
PDF file
VVVictoria Vitkova
Victoria Vitkova
VYVesela Yordanova
Vesela Yordanova
GSGalya Staneva
Galya Staneva
OPOgnyan Petkov
Ognyan Petkov
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova
GPGeorgi Popkirov
Georgi Popkirov
Simple carbohydrates are associated with the enhanced risk of cardiovascular disease and adverse changes in lipoproteins in the organism. Conversely, sugars are known to exert a stabilizing effect on biological membranes, and this effect is widely exploited in medicine and industry for cryopreservation of tissues and materials. In view of elucidating molecular mechanisms involved in the interaction of mono- and disaccharides with biomimetic lipid systems, we study the alteration of dielectric properties, the degree of hydration, and the rotational order parameter and dipole potential of lipid bilayers in the presence of sugars. Frequency-dependent deformation of cell-size unilamellar lipid vesicles in alternating electric fields and fast Fourier transform electrochemical impedance spectroscopy are applied to measure the specific capacitance of phosphatidylcholine lipid bilayers in sucrose, glucose and fructose aqueous solutions. Alteration of membrane specific capacitance is reported in sucrose solutions, while preservation of membrane dielectric properties is established in the presence of glucose and fructose. We address the effect of sugars on the hydration and the rotational order parameter for 1-palmitoyl-2-oleoyl-sn-glycero-3- phosphocholine (POPC) and 1-stearoyl-2-oleoyl-sn-glycero-3- phosphocholine (SOPC). An increased degree of lipid packing is reported in sucrose solutions. The obtained results provide evidence that some small carbohydrates are able to change membrane dielectric properties, structure, and order related to membrane homeostasis. The reported data are also relevant to future developments based on the response of lipid bilayers to external physical stimuli such as electric fields and temperature changes.

6 May 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova
VGVelizar Georgiev
Velizar Georgiev
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
Nickel-containing orthodontic archwires, particularly those made of nickel-titanium (NiTi) and stainless steel (SS), play a crucial role in orthodontic treatment using the fixed technique due to their mechanical properties. However, concerns regarding nickel-induced allergic reactions, cytotoxicity, and metal ion release, especially nickel-related ones, persist. This narrative review aims to explore recent findings on nickel release from orthodontic appliances, building upon prior systematic reviews by analyzing both in vitro and in vivo studies under various environmental conditions. The databases Web of Science, Scopus, and PubMed were searched for relevant studies that examined the relationship between nickel ion release from nickel-containing archwires and various environmental conditions. The studies found indicate that while metal ion release occurs during short-term treatment, the levels are lower than harmful thresholds, with factors such as pH, corrosion, length of treatment, and environmental influences affecting release rates. Despite this, long-term studies are few and are usually conducted only in an in vitro or in vivo environment, but not both. To establish causal relationships regarding metal ion release, in vivo monitoring of ions like Ni is critical, with further research needed to assess its prolonged effects. Furthermore, collaborative efforts among practitioners, researchers, and regulatory bodies are vital for developing evidence-based guidelines for orthodontic material selection, prioritizing patient safety and addressing metal ion release risks.

4 January 2023 in Materials
Verified
Journal Article
Open access
PDF file
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova
MGMirela Georgieva
Mirela Georgieva
VPValeri Georgiev Petrov
Valeri Georgiev Petrov
LALaura Andreeva
Laura Andreeva
APAlexander Petkov
Alexander Petkov
VGVelizar Georgiev
Velizar Georgiev
Multiforce orthodontic archwires are thermodynamic wires made of nickel-titanium alloy (Ni-Ti). They release biologically tolerable forces along their length, progressively increasing from front to back. The frontal archwires’ segments distribute the weakest force: the premolar, the greater, and the molar, the greatest. The aim of the present study was to determine the influence of clinical use on the mechanical properties of two types of multi-force orthodontic archwires (TriTanium®, American orthodontics; Bio-Active®, GC) with dimensions of 0.016 × 0.022 inches for periods of up to 8 weeks and over 8 weeks of in-vivo use. A three-point bending test was used, and the data gained is statistically analyzed through a multi-variance comparison Mann-Whitney test. We found that after uses of up to 8 weeks and over 8 weeks, the shape memory effect and superelasticity are preserved, as well as the tendency for differential force release along the length of the archwires is kept.

17 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova
MGMirela Georgieva
Mirela Georgieva
VPValeri Georgiev Petrov
Valeri Georgiev Petrov
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
LALaura Andreeva
Laura Andreeva
VGVelizar Georgiev
Velizar Georgiev
Multiforce nickel–titanium (NiTi) orthodontic archwires release progressively increasing forces in a front-to-back direction along their length. The properties of NiTi orthodontic archwires depend on the correlation and characteristics of their microstructural phases (austenite, martensite and the intermediate R-phase). From a clinical and manufacturing point of view, the determination of the austenite finish (Af) temperature is of the greatest importance, as in the austenitic phase, the alloy is most stable and exhibits the final workable form. The main purpose of using multiforce orthodontic archwires is to decrease the intensity of the applied forces to the teeth with a small root surface area, such as the lower central incisors, and also provide forces high enough to move the molars. With the optimally dosed forces of multiforce orthodontic archwires in the frontal, premolar and molar segments, the feeling of pain can be reduced. This will contribute to the greater cooperation of the patient, which is of utmost importance to achieve optimal results. The aim of this research was to determine the Af temperature at each segment of as-received and retrieved Bio-Active® and TriTanium® archwires with dimensions of 0.016 × 0.022 inches, investigated by the differential scanning calorimetry (DSC) method. A classical Kruskal–Wallis one-way ANOVA test and multi-variance comparison based on the ANOVA test statistic using the Bonferroni corrected Mann–Whitney test for multiple comparisons were used. The incisor, premolar and molar segments have different Af temperatures, and they decrease from the anterior to posterior so that the posterior segment has the lowest Af. Bio-Active® and TriTanium® with dimensions of 0.016 × 0.022 inches can be used as first leveling archwires by additional cooling and are not recommended for use on patients with mouth breathing.

29 December 2024 in Materials
Verified
Journal Article
Open access
PDF file
MGMirela Georgieva
Mirela Georgieva
Georgе PetkovGeorgе Petkov
Georgе Petkov
VPValeri Georgiev Petrov
Valeri Georgiev Petrov
LALaura Andreeva
Laura Andreeva
Jorge N.R. MartinsJorge N.R. Martins
Jorge N.R. Martins
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova
Rationale: Orthodontic archwires undergo chemical and structural changes in the complex intraoral environment. The present work aims to investigate the safe duration for intraoral use (related to the nickel release hypothesis) of different types of nickel-containing wires. By analyzing how the nickel content (NC) varies over time, we aim to provide practical recommendations for the optimal use of said archwires. Materials and Methods: Our analysis focuses on the following nickel-containing archwires: stainless steel, Ni-Ti superelastic, heat-activated NiTi and CuNiTi, and multi-force archwires. The studied archwires of each type were divided into three groups: group 1, as received; group 2, retrieved after intraoral exposure for less than 6 weeks; group 3, used for more than 8 weeks. To assess NC, measurements using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and laser-induced breakdown spectroscopy (LIBS) were performed in multiple regions of each wire. Statistical analysis of the measured values using one-way ANOVA and multiple group comparisons showed significant differences in nickel content between groups. The dynamic behavior of the statistical results for NC was then modeled using logistic regression and fitted with cubic splines. Conclusions: The proposed behavior model, with further refinement, could enable orthodontists to make informed, patient-specific decisions regarding the safe and effective use of orthodontic floss. The overall conclusion of the study is that due to stability, SS-CrNi, HA-Ni-Ti with Cu, and TriTaniumTM are suitable for long-term use, and due to higher nickel release, Ni-Ti-Superelastic, HA-Ni-Ti without Cu, and Bio-ActiveTM are better for short- to medium-term use.

1 January 2014 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
ASAnna Staneva
Anna Staneva
BBBlagoy Spasov Blagoev
Blagoy Spasov Blagoev
BSBoris Shivachev
Boris Shivachev
AZAndrzej Zaleski
Andrzej Zaleski
VMValdek Mikli
Valdek Mikli
ASAngelina Stoyanova-Ivanova
Angelina Stoyanova-Ivanova