Nuclear grade axial flow fans are widely used in nuclear power plants for ventilation and heat dissipation and have the advantages of high efficiency and high flow rates. A nuclear grade axial flow fan with OGVs (outlet guide vanes) can recover the kinetic energy of the dynamic impeller outlet winding to increase the ventilator pressure, thus improving the ventilator efficiency; therefore, the OGVs play an essential role in the performance of the axial flow fan. Based on accurate numerical simulations, an MRGP approximation model was developed to analyse the factors affecting the OGVs duct and optimise the guide vane structure, combined with the Sobol method for sensitivity analysis. The experiments and numerical simulations show that the total pressure of the optimised model increases by 154 Pa, and the noise decreases by 4.1 dB. The multi-objective optimisation method using the parametric approach and combining it with the MRGP model is highly reliable. It provides a key design direction for optimising nuclear grade axial flow fans.
Considering the complex flow state of the duct flow field in the exhaust system, the structural parameters can significantly impact the internal flow field and noise. This paper takes the noise generated by the duct system under operating conditions as the research object, studies the mechanism of duct noise generation through theoretical analysis, numerical simulation and experimental test, and proposes an optimization design method, that is, to improve the duct structure by adding duct guide vanes. In order to maximize the optimization effect of the guide vane, a multiobjective optimization design of its profile is required, including the parametric expression of the guide vane profile, establishing the design variables and optimization objectives, and establishing the Kriging approximation model. The IMOCS algorithm is used to accurately and efficiently calculate the Pareto front solution to obtain the optimal profile of the duct guide vane and finally improve the noise-reduction performance of the duct system. This paper applies this design method to an integrated stove head duct to verify its accuracy, and prototype tests are conducted according to the optimization results. The test results show that the optimized integrated cooker has improved the outlet flow rate of the whole machine by 1.2 m3/min and reduced the noise by 2.3 dB.
Large-scale backward-curved centrifugal fans without volutes are extensively employed in enclosed air-cooled electric motors owing to their exceptional heat dissipation performance. This category of fans features substantial blade dimensions and a multitude of optimization parameters, which introduce challenges such as diminished predictive accuracy in high-dimensional optimization spaces. To address these issues, this paper proposes a blade optimization design methodology based on a GA-Kriging surrogate model. Sobol’s global sensitivity analysis is first employed to reduce model dimensionality. Subsequently, a high-fidelity aerodynamic performance prediction model is constructed through the integration of a Genetic Algorithm (GA) and a Kriging model. A constrained optimization is then conducted with volumetric flow rate and static pressure as the design objectives, and shaft power along with geometric point coordinates as the constraints. Experimental test results demonstrate that the fan optimized via the surrogate model, while maintaining low prediction error, achieves a 14% increase in volumetric flow rate and a 20% improvement in static pressure. This outcome indicates a significant enhancement in the overall aerodynamic performance.