Radial flow adsorber (RFA) is widely used in large-scale pressure swing adsorption (PSA) oxygen production system because of high air separation. In this study, a 3-D modeling of gas–solid two-phase flow was established for the π-shaped centripetal RFA (CP-π RFA). The pressure difference, temperature changes, velocity profiles and oxygen distributions were comparatively studied using this model. Part of the results have been compared with the experiments results, which shows this model can give an accurately prediction. The results show that the pressure and velocity in the adsorber change greatly near the outer hole and central hole, but the overall pressure and velocity changes in the bed are stable. The oxygen product purity in the adsorbent filling area performed better on oxygen enrichment after eight cycles. The oxygen product flow rate will affect the oxygen production performance. The laws of the pressure, velocity, temperature and oxygen distributions can provide an important technical reference for CP-π RFA in the PSA for oxygen production.
People who live and work in air-conditioned rooms with micro-hypoxia are prone to sick building syndrome (SBS). Enriching oxygen into an air-conditioned room to increase the oxygen concentration can improve indoor air quality (IAQ) and reduce ventilation to save building energy consumption. In the present paper, the number and diameter of the oxygen supply vents, the oxygen supply flow rate, the oxygen supply method and the air flow organization form were comparatively studied using a numerical model. The results were compared with the experiments results in un-air-conditioned rooms, which showed that this model can give a favorable prediction. The results show that the maximum axial velocity decreases with the increase of the axial distance under air-conditioned conditions. The relationship between the oxygen-enriched area and the oxygen flow rate is obtained by fitting. The diameter of the oxygen supply pipe is 0.006 m, and when oxygen supply methods 1# and 4# are adopted, the oxygen-enriched area is F = 0.4 + 0.383 Q and F = 0.237 + 0.8 Q, respectively.