A robust laser measurement system (LMS), consisting of a sensor head and a detecting part, for simultaneously measuring five-degree-of-freedom (five-DOF) error motions of linear stages, is proposed and characterized. For the purpose of long-travel measurement, all possible error sources that would affect the measurement accuracy are considered. This LMS not only integrates the merits of error compensations for the laser beam drift, beam spot variation, detector sensitivity variation, and non-parallelism of dual-beam that have been resolved by the author’s group before, but also eliminates the crosstalk errors among five-DOF error motions in this study. The feasibility and effectiveness of the designed LMS and modified measurement model are experimentally verified using a laboratory-built prototype. The experimental results show that the designed LSM has the capability of simultaneously measuring the five-DOF error motions of a linear stage up to one-meter travel with a linear error accuracy in sub-micrometer and an angular error accuracy in sub-arcsecond after compensation.
This paper presents a miniature three-degree-of-freedom laser measurement (3DOFLM) system for displacement feedback and error compensation of a nanopositioning stage. The 3DOFLM system is composed of a miniature Michelson interferometer (MMI) kit, a wavelength corrector kit, and a miniature autocollimator kit. A low-cost laser diode is employed as the laser source. The motion of the stage can cause an optical path difference in the MMI kit so as to produce interference fringes. The interference signals with a phase interval of 90° due to the phase control are detected by four photodetectors. The wavelength corrector kit, based on the grating diffraction principle and the autocollimation principle, provides real-time correction of the laser diode wavelength, which is the length unit of the MMI kit. The miniature autocollimator kit based on the autocollimation principle is employed to measure angular errors and compensate induced Abbe error of the moving table. The developed 3DOFLM system was constructed with dimensions of 80 mm (x) × 90 mm (y) × 20 mm (z) so that it could be embedded into the nanopositioning stage. A series of calibration and comparison experiments were carried out to test the performance of this system.
The geometric error motions of rotary stages greatly affect the accuracy of constructed machines such as machine tools, measuring instruments, and robots. In this paper, an embedded sensor system for real-time measurement of two radial and three angular error motions of a rotary stage is proposed, which makes use of a rotary encoder with multiple scanning heads to measure the rotational angle and two radial error motions and a miniature autocollimator to measure two tilt angular errors of the axis of rotation. The assembly errors of the grid disc of the encoder and the mirror for autocollimator are also evaluated and compensated. The developed measuring device can be fixed inside the rotary stage. In the experiments, radial error motions of two points on the axis (h = 5 mm and 60 mm) were measured and calibrated with LVDTs, and the data showed that the radial error motions of the axis were less than 20 μm, and the calibration residual errors were less than 2 μm. When intermittent external forces were applied to the stage, the change of the stage’s error motion could also be monitored accurately.
27 July 2022 in IEEE/ASME Transactions on Mechatronics
Laser trackers are usually used to measure spatial positional error of the moving targets on large-scaled objects, such as the airplane profile. It is a spherical coordinate system with a dual-axis tracking mirror actively controlled by the built-in servo system to direct the laser interferometer beam always toward the reflecting target. It is very expansive when used in testing the spatial positional accuracy of industrial robots, which are rapidly growing for factory automation in recent years. Therefore, simplified from the laser tracker structure, a 3D passive laser tracker (3DPLT) for measuring spatial trajectory of a moving target is proposed. It is composed of a 2D rotary stage and a linear telescopic mechanism with an end-ball, which can be magnetically sucked by the moving target. The rotational angles of the 2D rotary stage are measured by two respective encoders, and the radial displacement of the telescopic mechanism is detected by an equipped laser interferometer. The world coordinate of the target can be obtained by the coordinate transformation from the spherical measuring system of 3DPLT. Multibody system error modeling is used to analyze the measurement error of the instrument, and testing methods of the main error sources are also proposed. After accuracy calibration and error compensation, the measurement error of the 3DPLT is 49.2 μm, which is good enough to calibrate the spatial trajectory error of the robot.
In gear measuring machines (GMMs), the tested gear is mounted on a mandrel, which is pivoted at both ends by two centers in a vertical arrangement. The upper center is fixed and the lower center is driven by the spindle of rotation. The coaxiality error between the central line of the mandrel and the spindle average line of a GMM always exists in terms of the offset and angle measured in one plane. Such a coaxiality error would cause an angular indexing error of tested gear resulting in measurement error. This phenomenon has rarely been investigated. In this paper, a GMM is taken as an example and its coaxiality error of the mandrel and spindle error of the rotary stage are measured. The difference of rotated angles between the mandrel and spindle is theoretically analyzed by derived formulae. Calibrated by a precision polygon and an autocollimator, the predicted angular index error of the mandrel was consistent with experimental results. Through the experimental verification, it was found that, when the coaxial deviation between the two centers was 10 μm and the lower center tip’s radial motion error was 1.6 μm, the angular indexing deviation of the mandrel was ±5″. If the errors were compensated according to the analyzed model, the residual error was reduced to ±2″. A significant improvement in the angular positioning accuracy of the GMM can be achieved.
Currently, the widely used pendulum-type precision level cannot be miniaturized because reducing the size of the pendulum will reduce its displacement so as to decrease the measurement accuracy and resolution. Moreover, the commercial pendulum-type level can only sense one direction. In this paper, an innovative compact and high-accuracy dual-axis precision level is proposed. Based on the optical principle of light refraction and the reference of the invariant liquid level, the pendulum is no more needed. In addition, based on the light transmission design, there is no reflection signal to interfere with the true signal. Therefore, the level can achieve a high accuracy and small-sized design. The calibration result shows the error of the proposed precision level is better than ±0.6 arc-sec in the measurement range of ±100 arc-sec, and better than ±5 arc-sec in the full measurement range of ±800 arc-sec.