Currently, the widely used pendulum-type precision level cannot be miniaturized because reducing the size of the pendulum will reduce its displacement so as to decrease the measurement accuracy and resolution. Moreover, the commercial pendulum-type level can only sense one direction. In this paper, an innovative compact and high-accuracy dual-axis precision level is proposed. Based on the optical principle of light refraction and the reference of the invariant liquid level, the pendulum is no more needed. In addition, based on the light transmission design, there is no reflection signal to interfere with the true signal. Therefore, the level can achieve a high accuracy and small-sized design. The calibration result shows the error of the proposed precision level is better than ±0.6 arc-sec in the measurement range of ±100 arc-sec, and better than ±5 arc-sec in the full measurement range of ±800 arc-sec.
This study compares one traditional prediction model—the conventional single-variable interpolation method—with two newly developed models: an improved multi-variable interpolation model extended from the single-variable formulation, and a more advanced NURBS-based multi-variable interpolation model. All models are integrated into a real-time volumetric error compensation framework embedded within a CNC controller, enabling in-kernel correction without external hardware. Accuracy verification is carried out using planar body diagonal measurements obtained from a dense on-machine PDGE data grid across the coupling plane. Quantitatively, the improved multi-variable interpolation model reduces diagonal errors by 71%–74%, while the NURBS-based model achieves 82% (T1) and 84% (T2) reductions, delivering an additional 18%–19% improvement relative to the single-variable baseline. The in-kernel evaluation satisfies 2–4 ms interpolation cycles, confirming real-time feasibility. The proposed framework provides a compact, data-driven solution for predicting and compensating cross-talk-induced PDGEs in precision machine tools.
Geometric errors in CNC machine tools accumulate along the tool path and directly affect machining accuracy. Traditional serial-chain-based volumetric error models, such as those based on the homogeneous transformation matrix (HTM) or screw theory, often exhibit ambiguous geometric definitions, weak traceability to measurement points, and increased computational cost due to repeated coordinate transformations and inverse mappings, limiting their suitability for real-time control. To overcome these challenges, this study proposes a parallel-type unified error vector transfer (EVT) framework, based on the Abbe and Bryan principles. In this framework, axis error motions are directly expressed as vectors and transferred to the tool center point (TCP), where they are superimposed to obtain total error contributions. Building on this principle, a unified normal volumetric error model (NVEM) is formulated using survival and sign factors. The unified NVEM is applicable to various types of three-axis machining centers, including horizontal configurations. In other words, differences in coordinate system definitions can be reconciled through coordinate transformation, allowing the unified NVEM to be consistently applied. Furthermore, a real-time error compensation controller (RECC) is embedded into the CNC kernel to compute compensation values within each interpolation cycle, ensuring deterministic and low-latency operation without external computation. Experimental validations on an XYFZ-type vertical machining center demonstrate that the proposed framework improves positioning accuracy by more than 72% and machining accuracy by 60.4%. These results confirm the feasibility, efficiency, and universality of the parallel-type unified EVT framework for real-time volumetric error compensation. Here, ‘parallel-type’ denotes the parallel superposition of independent error vector contributions, rather than a parallel kinematic mechanism.
15 October 2026 in Measurement Science and Technology
The rotation of a rotary table inevitably induces six typical motion errors. To improve the measurement efficiency and accuracy of rotary table motion error detection, this paper proposes a novel system for the simultaneous online measurement of six-degree-of-freedom (6-DOF) motion errors. The system consists of a 5-DOF measurement module and an independent angular position error measurement module. The proposed system innovatively integrates an axial motion error measurement module into the original 4-DOF measurement framework. Based on the optical collimation principle, the system employs a beam-splitting flat plate to split the light beam of the original 4-DOF optical path, enabling real-time monitoring of the axial motion error of the rotary table. Meanwhile, an optical path adjustment strategy for axial motion error detection is proposed. Based on geometric analysis, an error model is constructed to eliminate the interference of radial and tilt motion errors on axial motion measurement, thereby achieving accurate acquisition of six-dimensional motion errors. The experimental results indicate that the angular error measurement accuracy of the proposed system is ±2″ within a measurement range of ±100″, with a standard deviation ( σ ) of 1.3″. For linear error measurement, the accuracy reaches ±3 μm over the ±100 μm range, accompanied by a standard deviation of 1.7 μm. The experimental results confirm the favorable accuracy and stability of the proposed 6-DOF measurement system for rotary table error measurement. Therefore, the system is applicable to precision rotary tables (⩾2 σ ), and future work will focus on performance optimization to extend its capability to ultra-precision rotary axis measurement.