Scanning tunneling microscopy (STM) can image material surfaces with atomic resolution, making it a useful tool in the areas of physics and materials. Many materials are synthesized at micron size, especially few-layer materials. Limited by their complex structure, very few STMs are capable of directly positioning and imaging a micron-sized sample with atomic resolution. Traditional STMs are designed to study the material behavior induced by temperature variation, while the physical properties induced by magnetic fields are rarely studied. In this paper, we present the design and construction of an atomic-resolution STM that can operate in a 9 T high magnetic field. More importantly, the homebuilt STM is capable of imaging micron-sized samples. The performance of the STM is demonstrated by high-quality atomic images obtained on a graphite surface, with low drift rates in the X–Y plane and Z direction. The atomic-resolution image obtained on a 32-μm graphite flake illustrates the new STM’s ability of positioning and imaging micron-sized samples. Finally, we present atomic resolution images at a magnetic field range from 0 T to 9 T. The above advantages make our STM a promising tool for investigating the quantum hall effect of micron-sized layered materials.

7 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
AAAsim Abas
Asim Abas
TGTao Geng
Tao Geng
WMwenjie meng
wenjie meng
JWJihao Wang
Jihao Wang
QFQiyuan Feng
Qiyuan Feng
Qingyou LuQingyou Lu
Qingyou Lu
Magnetic Force Microscopy (MFM) is among the best techniques for examining and assessing local magnetic characteristics in surface structures at scales and sizes. It may be viewed as a unique way to operate atomic force microscopy with a ferromagnetic tip. The enhancement of magnetic signal resolution, the utilization of external fields during measurement, and quantitative data analysis are now the main areas of MFM development. We describe a new structure of MFM design based on a cryogen-free superconducting magnet. The piezoelectric tube (PZT) was implemented with a tip-sample coarse approach called SpiderDrive. The technique uses a magnetic tip on the free end of a piezo-resistive cantilever which oscillates at its resonant frequency. We obtained a high-quality image structure of the magnetic domain of commercial videotape under extreme conditions at 5 K, and a high magnetic field up to 11 T. When such a magnetic field was gradually increased, the domain structure of the videotape did not change much, allowing us to maintain the images in the specific regions to exhibit the performance. In addition, it enabled us to locate the sample region in the order of several hundred nanometers. This system has an extensive range of applications in the exploration of anisotropic magnetic phenomena in topological materials and superconductors.

2 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
KXkui xiang
kui xiang
CXCaihong Xie
Caihong Xie
QFQiyuan Feng
Qiyuan Feng
ZWZe Wang
Ze Wang
GDGuangbin Dai
Guangbin Dai
Yalin LuYalin Lu
Yalin Lu
Recently, there has been growing interest in using lightwave-driven scanning probe microscopy (LD-SPM) to break through the Abbe diffraction limit of focusing, yielding insight into various energy couplings and conversion processes and revealing the internal information of matter. We describe a compact and efficient optical cryostat designed for LD-SPM testing under magnetic fields. The exceptional multilayer radiation shielding insert (MRSI) forms an excellent temperature gradient when filled with heat conducting gas, which removes the requirement to install an optical window in the liquid helium cooling shell. This not only critically avoids the vibration and thermal drift caused by solid heat conduction but also minimizes light transmission loss. The application of gate valves and bellows allows a simpler and more effective replacement of the sample and working cell in the test cavity. ANSYS software is used for steady-state thermal analysis of the MRSI to obtain the temperature distribution and heat transfer rate, and the necessity of the flexible copper shielding strips is illustrated by the simulations. The topography and magnetic domain images of 45 nm-thick La0.67Ca0.33MnO3 thin films on NdGaO3(001) substrates under a magnetic field were obtained by a self-made lightwave-driven magnetic force microscope in this cryostat. The resolution and noise spectra during imaging reveal temperature stability and low vibration throughout the cryostat. The experience acquired during the development of this cryostat will help to establish cryostats of similar types for a variety of optic applications requiring the use of cryogenic temperatures.