Asim Abas

Mr. Asim Abas


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2022 in Journal of Applied Electrochemistry
Verified
Journal Article
Closed access
PDF file
AAAsim Abas
Asim Abas
Altyeb Ali Abaker OmerAltyeb Ali Abaker Omer
Altyeb Ali Abaker Omer
LWLan Wei
Lan Wei
Qingyou LuQingyou Lu
Qingyou Lu

10 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
MAMadiha Ahmed
Madiha Ahmed
YQYuming Qi
Yuming Qi
LZLonglong Zhang
Longlong Zhang
YYyanxia yang
yanxia yang
AAAsim Abas
Asim Abas
BCBaocheng Cao
Baocheng Cao
The objectives of this study were to reduce the corrosion rate and increase the cytocompatibility of AZ31 Mg alloy. Two coatings were considered. One coating contained MgO (MAO/AZ31). The other coating contained Cu2+ (Cu/MAO/AZ31), and it was produced on the AZ31 Mg alloy via microarc oxidation (MAO). Coating characterization was conducted using a set of methods, including scanning electron microscopy, energy-dispersive spectrometry, X-ray photoelectron spectroscopy, and X-ray diffraction. Corrosion properties were investigated through an electrochemical test, and a H2 evolution measurement. The AZ31 Mg alloy with the Cu2+-containing coating showed an improved and more stable corrosion resistance compared with the MgO-containing coating and AZ31 Mg alloy specimen. Cell morphology observation and cytotoxicity test via Cell Counting Kit-8 assay showed that the Cu2+-containing coating enhanced the proliferation of L-929 cells and did not induce a toxic effect, thus resulting in excellent cytocompatibility and biological activity. In summary, adding Cu ions to MAO coating improved the corrosion resistance and cytocompatibility of the coating.

1 August 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
MTMuhammad Touqeer
Muhammad Touqeer
SMSyed Asad Maqbool
Syed Asad Maqbool
BEBehnam Esmaeilzadeh
Behnam Esmaeilzadeh
SZShaofeng Zheng
Shaofeng Zheng
WMWenjie Meng
Wenjie Meng
Qingyou LuQingyou Lu
Qingyou Lu
We introduce a novel piezoelectric stepper motor featuring high compactness, rigidity, and any direction operability. Here, not only is the structure of high novelty but also the working principle very simple. The piezo stacks unit is sandwiched between two spring finger pieces, with almost equal clamping forces applied between the top of the piezo stacks’ unit and the spring finger piece. Applying individual driving signals to each of the five piezo stack pairs, causing deformation one by one in the same direction, followed by simultaneous recovery in the reverse direction, enables movement of the frame part. The optimized clamping force of the piezoelectric stack units and spring fingers ensures maximum output force. The motor’s operational capability at low threshold voltages, specifically 8 V for downward movement and 10 V for upward movement, confirmed its efficacy in both vertical and horizontal directions. The motor’s operational capability at a low threshold voltage of 10 V confirmed its efficacy in both vertical and horizontal directions. At room temperature, step size ranges from 0.3 to 7.4 µm at 20 Hz frequency and varying driving voltage from 10 to 180 V. It has a maximum travel range of about 5 mm and can lift a maximum load of 220 g in an upward direction, so the maximum output force generated by this motor is 2.2 N. The compact and rigid design is capable of building an atomically resolved scanning probe microscope, and its working ability has the potential to use the cleavage of different types of samples in limited space environments, such as the small-bore superconducting magnet and low temperature.

7 November 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
AAAsim Abas
Asim Abas
TGTao Geng
Tao Geng
WMwenjie meng
wenjie meng
JWJihao Wang
Jihao Wang
QFQiyuan Feng
Qiyuan Feng
Qingyou LuQingyou Lu
Qingyou Lu
Magnetic Force Microscopy (MFM) is among the best techniques for examining and assessing local magnetic characteristics in surface structures at scales and sizes. It may be viewed as a unique way to operate atomic force microscopy with a ferromagnetic tip. The enhancement of magnetic signal resolution, the utilization of external fields during measurement, and quantitative data analysis are now the main areas of MFM development. We describe a new structure of MFM design based on a cryogen-free superconducting magnet. The piezoelectric tube (PZT) was implemented with a tip-sample coarse approach called SpiderDrive. The technique uses a magnetic tip on the free end of a piezo-resistive cantilever which oscillates at its resonant frequency. We obtained a high-quality image structure of the magnetic domain of commercial videotape under extreme conditions at 5 K, and a high magnetic field up to 11 T. When such a magnetic field was gradually increased, the domain structure of the videotape did not change much, allowing us to maintain the images in the specific regions to exhibit the performance. In addition, it enabled us to locate the sample region in the order of several hundred nanometers. This system has an extensive range of applications in the exploration of anisotropic magnetic phenomena in topological materials and superconductors.

1 March 2024 in AIP Advances
Verified
Journal Article
Open access
PDF file
AAAsim Abas
Asim Abas
TGTao Geng
Tao Geng
WMWenjie Meng
Wenjie Meng
MTMuhammad Touqeer
Muhammad Touqeer
BEBehnam Esmaeilzadeh
Behnam Esmaeilzadeh
Qingyou LuQingyou Lu
Qingyou Lu
To obtain high-resolution magnetic force microscopy (MFM) images, it is essential to have a cantilever with a high-quality factor. However, conventional vibrating cantilevers typically have quality factor values in the range of a few hundred, which limits their sensitivity for MFM measurements. To address this limitation, numerous studies have explored methods to enhance the quality factor in different environments, including vacuum, air, and liquid. This study introduces a novel approach for improving the quality factor using flowing helium gas. By selecting helium gas with a low viscosity coefficient, we successfully achieved a higher quality factor (Q-factor) of MFM microcantilever oscillations at room temperature in one atmosphere compared with the Q-factor in air. This provides a potential approach for achieving high-resolution MFM measurements under room temperature conditions. By optimizing the gas flow rate at room temperature in one atmosphere, we successfully obtained a higher MFM cantilever oscillation Q-factor and clearer MFM images compared with the air. The experimental results revealed a long and narrow resonant curve, and the quality factor significantly increased to 778.2, which is 3.8 times higher than that observed in air 205.4. Furthermore, systematic investigations demonstrated the capability of this approach to produce high-resolution MFM images of videotape track patterns under the optimized helium gas flow rate of 60 mm/s.

30 January 2024 in Research Square
Verified
Preprint
Open access
PDF file
ZYZhiwei Yang
Zhiwei Yang
AAAsim Abas
Asim Abas
The power semiconductor industry, as the cornerstone of the information industry, has become an important indicator for measuring the technological level and development scale competitiveness of an industry, and is also an indispensable part of the energy industry. In order to promote the development of the semiconductor industry and enhance its innovation capabilities and competitiveness, it is necessary to seize the development opportunities in the semiconductor chip market. Therefore, based on elucidating the development direction of thyristor chip structure design, novel gate-level structures and multilayer semiconductor structures have been designed with the aim of improving the triggering current and dynamic characteristics of thyristor chips.